Datasheet

3
G5V-1 Low Signal Relay
G
5
V
-
1
Engineering Data
*1. The tests were conducted at an ambient temperature of 23°C.
*2. The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary
according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use.
High-frequency Characteristics
Test Conditions
Maximum Switching Capacity Durability Ambient Temperature vs.
Maximum Coil Voltage
Note: The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
Ambient Temperature vs. Must
Operate or Must Release Voltage
G5V-1 G5V-1-T90
Shock Malfunction
Test conditions: Shock is applied in ±X, ±Y, and
±Z directions three times each with and without
energizing the Relays to check the number of
contact malfunctions.
Dial Pulse Test *1 Contact Reliability Test *1, *2
Switching current (A)
5
3
1
0.7
0.5
0.3
0.1
10 30 50 70 100 300 500
Switching voltage (V)
DC resistive load AC resistive
load
125 VAC
resistive load
24 VDC resistive load
Durability (x10
4
operations)
500
300
100
70
50
30
10
7
5
0 0.2 0.4 0.6 0.8 1.0 1.2
Switching current (A)
Maximum coil voltage (%)
250
200
150
100
50
0
Ambient temperature (°C)
−40 −20 0 20 40
60 8070 90 100
Standard
G5V-1-T90
On the basis of rated voltage (%)
100
80
60
40
20
0
-60 -40 -20 0 20 40 60 80 100
Ambient temperature (°C)
Sample: G5V-1
Number of Relays: 10 pcs
max.
max.
X
X
min.
min.
Must operate voltage
Must release voltage
Z
Z'
Y
Y'
X
X'
200
400
600
800
800
600
400
200
1,000
1,000
1,0001,000
1,000
1,000
Shock direction
Unit: m/s
2
Sample: G5V-1 12 VDC
Number of Relays: 10 pcs
Y
Y'
XX'
De-
energized
Energized
Z
Z'
0 50 100 500 1,000 5,000
10,000 50,000
Rotation (×10
3
turns)
80
70
60
50
40
30
20
10
1,000
500
300
100
50
30
10
On the basis of rated voltage (%)
Contact resistance (m
Ω
)
Must operate voltage
Contact resistance
Must release voltage
Sample: G5V-1 12 VDC
Number of Relays: 6 pcs
Test conditions: Contact load
WJ-139 (with arc-killer)
Switching frequency: 20PPS
max.
min.
max.
min.
max.
max.
min.
min.
NO
contact
NC
contact
1,000
500
400
300
200
100
50
40
30
20
10
0 5 10 50 100 500 1,000
Operating frequency (×10
4
operations)
Contact resistance (m
Ω
)
Sample: G5V-1 12 VDC
Number of Relays: 10 pcs
Test conditions: Resistive
load at 5 VDC 1 mA
Switching frequency:
7,200 operations/h
NO contact
NC contact
min.
min.
max.
max.
Terminals which were not being measured were terminated with 50 Ω.
Measuring impedance: 50 Ω
HR 8502A
Transmission
reflection
test-set
Terminator
50Ω
G5V-1
HR 8502A
Network
analyzer
HP
8501A
Storage
normalizer
RF
R
A
B
Note: The high-frequency characteristics data were measured using a dedicated circuit board and
actual values will vary depending on the usage conditions. Check the characteristics of the actual
equipment being used.