Datasheet

4
G5V-2 Low Signal Relay
G
5
V
-
2
Dimensions
Approved Standards
UL recognized: (File No. E41515)
CSA certified: (File No. LR31928)
Precautions
Please refer to “PCB Relays Common Precautions” for correct use.
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON
continuously for long periods (without switching) can lead to
unstable contacts because the heat generated by the coil itself
will affect the insulation, causing a film to develop on the contact
surfaces. Be sure to use a fail-safe circuit design that provides
protection against contact failure or coil burnout.
Relay Handling
When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent, and keep
the solvent temperature to less than 40°C. Do not put the Relay
in a cold cleaning bath immediately after soldering.
46
1 8
11
91316
20.5max.
(20.3)*
10.1max.
(9.9)*
11.5max.
(11.4)*
* Average value
0.5
3.5
7.62
0.3
0.5
0.4
2.54
2.54
7.62 5.08 5.08
(1.2)
(1.2)
(1.3)(1.3)
7.62
Eight, 1 dia. holes
Orientation marks are indicated as follows:
(No coil polarity)
G5V-2
PCB Mounting Holes (Bottom View)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(Bottom View)
Note: Each value has a tolerance of ±0.3 mm.
Model
Contact
form
Coil
ratings
Contact ratings Number of
test
operations
G5V-2 G5V-2-H1
G5V-2
DPDT
(2c)
3 to 48
VDC
2 A, 30 VDC at 40°C
0.6 A, 110 VDC at 40°C
0.6 A, 125 VAC at 40°C
2 A, 24 VDC at 40°C
0.2 A, 110 VDC at 40°C
0.5 A, 125 VAC at 40°C
6,000
Correct Use
· Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
· Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K046-E1-06
0316(0207)(O)
Note: Do not use this document to operate the Unit.