Datasheet

247
Text
246
Text PCB Signal Relay – G5V-2
Maximum Switching Power
G5V-2
Ambient Temperature vs.
Maximum Coil Voltage
G5V-2
Endurance
G5V-2
Switching current (A)
Switching voltage (V) Switching current (A)
Endurance (x10 operations)
3
Ambient temperature (°)
Maximum coil voltage (%)
Coil rated voltage
3 to 24 VDC
48 VDC
30-VDC
resistive
load
125-VAC resistive
load
123
AC resistive load
DC re
sistive
load
G5V-2-H1 G5V-2-H1G5V-2-H1
Switching current (A)
Switching voltage (V) Switching current (A)
Life expectancy (x10 operations)
3
Ambient temperature (°)
Maximum coil voltage (%)
AC resistive
load
DC resistive load
5
3
1
0.7
0.5
0.3
0.2
0.1
0
24-VDC resistive load
125-VAC resistive load
1000
500
300
100
50
30
10
3 to 24 VDC
48 VDC
200
180
160
140
120
100
80
0
Note: The maximum coil voltage refers to the maxi-
mum value in a varying range of operating
power voltage, not a continuous voltage.
Note: The maximum coil voltage refers to the maxi-
mum value in a varying range of operating
power voltage, not a continuous voltage.
Engineering Data
Signal Relays
PCB Signal Relay – G5V-2
Approved Standards
UL (File No. E41515)/CSA C22.2 No.0,
No.14 (File No. LR24825)
Characteristics
Item Standard models High sensitivity models
Contact resistance (see note 1) 50 mΩ max. 100 mΩ max.
Operate time 7 ms max.
Release time 3 ms max.
Max. operating frequency Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance (see note 2) 1,000 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between coil 1,000 VAC, 50/60 Hz for 1 min between coil
and contacts and contacts
1,000 VAC, 50/60 Hz for 1 min between 1,000 VAC, 50/60 Hz for 1 min between
contacts of different polarity contacts of different polarity
750 VAC, 50/60 Hz for 1 min between 500 VAC, 50/60 Hz for 1 min between
contacts of same polarity contacts of same polarity
Impulse withstand voltage 1,00 V (10 x 160 µs) between coil and contacts (conforms to FCC part 68)
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance Destruction: 1,000 m/s
2
(approx. 100G) Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 200 m/s
2
(approx. 20G) Malfunction: 100 m/s
2
(approx. 10G)
Endurance Mechanical: 15,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr)
Ambient temperature Operating: -25˚C to 65˚C (with no icing) Operating: -25˚C to 70˚C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 5 g
Contact form Coil rating Contact rating
G5V-2 G5V-2-H1
DPDT 3 to 48 VDC 0.6 A, 125 VAC (general use) 0.5 A, 125 VAC (general use)
0.6 A, 110 VDC (resistive load) 0.2 A, 110 VDC (resistive load)
2 A, 30 VDC (resistive load) 1 A, 24 VDC (resistive load)
Note: The above values are initial values.
1. The contact resistance was measured with 10mA at 1VDC with a voltage drop method.
2. The insulation resistance was measured with a 500VDC megohmeter applied to the same parts as those used for checking
the dielectric strength.
Omron 08 Cat 1-302 5/10/07 15:39 Page 246