Datasheet

175
G6BG6B
Contact Ratings
Note: P level: λ
60
= 0.1 x 10
-6
/operation
Characteristics
Note: The data shown above are initial values.
Item SPST-NO SPST-NO + SPST-NC, DPST-NO, DPST-NC
Load Resistive load
(cos
φ = 1)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Rated load 5 A at 250 VAC;
5A at 30 VDC
2 A at 250 VAC;
2 A at 30 VDC
5 A at 250 VAC;
5A at 30 VDC
1.5 A at 250 VAC;
1.5 A at 30 VDC
Contact material Ag Alloy (Cd free)
Rated carry current 5 A
Max. switching voltage 380 VAC, 125 VDC
Max. switching current 5 A
Max. switching power 1,250 VA, 150 W 500 VA, 60 W 1,250 VA, 150 W 375 VA, 80 W
Failure rate (reference value) 10 mA at 5 VDC
Item SPST-NO (High-capacity)
Load Resistive load (cos
φ = 1) Inductive load (cosφ = 0.4; L/R = 7 ms)
Rated load 8 A at 250 VAC; 8 A at 30 VDC 2 A at 250 VAC; 2 A at 30 VDC
Contact material Ag Alloy (Cd free)
Rated carry current 8 A
Max. switching voltage 380 VAC, 125 VDC
Max. switching current 8 A
Max. switching power 2,000 VA, 150 W
Failure rate (reference value) 10 mA at 5 VDC
Contact resistance 30 m
max.
Operate (set) time 10 ms max. (mean value: 1-pole approx. 3 ms, 2-pole approx. 4 ms)
Release (reset) time Single-side stable types: 10 ms max. (mean value: 1-pole approx. 1 ms, 2-pole approx. 2 ms)
Latching types: 10 ms max. (mean value: approx. 3 ms)
Min. set/reset signal width Latching type: 15 ms min. (at 23°C)
Max. operating frequency Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 M
min. (at 500 VDC, at 250 VDC between set coil and reset coil)
Dielectric strength 3,000 VAC (Latching types: 2,000 VAC), 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
250 VAC, 50/60 Hz for 1 min between set and reset coils
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s
2
Malfunction: Single-side stable: 100 m/s
2
; Latching: 300 m/s
2
Endurance Mechanical: 50,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operation min. (at 1,800 operations/hr)
Ambient temperature Operating:
25°C to 70°C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Double-winding latching: Approx. 3.7 g
High-capacity: Approx. 4.6 g
Double pole: Approx. 4.5 g
Other: Approx. 3.5 g