Datasheet
9
G6B PCB Power Relay
G
6
B
■Approved Standards
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm the
values before use.
UL Recognized:
(File No. E41643)
CSA Certified: (File No. LR31928)
EN/IEC, TÜV Certified: (Registration No. R50158246)
Model
Contact
form
Coil
ratings
Contact ratings
Number of test
operations
G6B-1114P-US
G6B-1114P-FD-US
1
3 to 24
VDC
5 A, 250 VAC (General Use) at 80°C
6,000
5A, 30 VDC at 80°C
1/8HP, 250 VAC at 80°C
1,000
1/6HP, 250 VAC at 80°C
G6B-1174P-US
G6B-1174P-FD-US
1
3 to 24
VDC
8 A, 250 VAC (General Use) at 80°C
6,000
8 A, 30 VDC at 80°C
G6B-2114P(-FD)-US
G6B-2214P(-FD)-US
G6B-2014P(-FD)-US
2
3 to 48
VDC
5 A, 250 VAC (General Use) at 40°C
5 A, 30 VDC at 40°C
Model
Contact
form
Coil
ratings
Contact ratings
Number of test
operations
G6B-1114P-US
G6B-1114P-FD-US
1
3 to 24
VDC
5 A, 250 VAC (General Use) at 80°C
6,000
5A, 30 VDC at 80°C
1/6HP, 250 VAC at 80°C
1,000
360WT, 120 VAC at tungsten 80°C
G6B-1174P-US
G6B-1174P-FD-US
1
3 to 24
VDC
8 A, 250 VAC (General Use) at 80°C
6,000
8 A, 30 VDC at 80°C
G6B-2114P(-FD)-US
G6B-2214P(-FD)-US
G6B-2014P(-FD)-US
2
3 to 48
VDC
5 A, 250 VAC (General Use) at 40°C
5 A, 30 VDC at 40°C
Model
Contact
form
Coil
ratings
Contact ratings
Number of test
operations
G6B-1114P-US 1
3 to 48
VDC
5 A, 250 VAC (cosφ = 1) at 70°C
20,000
2 A, 250 VAC (cosφ = 0.4) at 70°C
5 A, 30 VDC (L/R = 0 ms) at 70°C
G6B-1174P-US 1
3 to 48
VDC
8 A, 250 VAC (cosφ = 1) at 70°C
2 A, 250 VAC (cosφ = 0.4) at 70°C
8 A, 30 VDC (L/R = 0 ms) at 70°C
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
2
3 to 48
VDC
5 A, 250 VAC (cosφ = 1) at 70°C
1.5 A, 250 VAC (cosφ = 0.4) at 70°C
5 A, 30 VDC (L/R = 0 ms) at 70°C