Datasheet
7
G6B PCB Power Relay
G
6
B
■Dimensions (Unit: mm)
● Shock Malfunction
● Hot Start
Z'
Z
Unit: m/s
2
Y
Y'
X
X'
Energized
200
100
300
400
200
100
300
300
300
400
Shock direction
Y
Y'
X
X'
Z
Z'
(Coil)
Sample: G6B-1114P-US
Number of Relays: 12 pcs
Test Conditions: Shock is applied in ±X, ±Y,
and ±Z directions three times each with without
energizing the Relays
to check the number of
malfunctions.
Requirement: None
malfuction 100 m/s
2
Z'
Z
Unit: m/s
2
Y
Y'
X
X'
Energized
600
1,000
1,000
1,000
1,000
1,000
1,000
Shock direction
Y
Y'
X
X'
Z
Z'
(Coil)
Sample: G6B-1174P-US
G6B-1174P-FD-US
Test Conditions: Shock is applied in ±X, ±Y,
and ±Z directions three times each with without
energizing the Relays
to check the number of
malfunctions.
Requirement: None
malfuction 100 m/s
2
Z'
Shock direction
Y
Y'
X
X'
Z
Z'
(Coil)
Z
Unit: m/s
2
Y
Y'
X
X'
1,000
1,000
1,000
1,0001,000
1,000
Reset
Set
700
Sample: G6BK-1114P-US
Number of Relays: 12 pcs
Test Conditions: The value at which
malfunction occurred was measured after
applying shock to the
test piece 3 times each
in 6 directions along 3
axes.
Standard value:
300 m/s
2
Ambient temperature (°C)
Sample: G6B-1114P-US
G6B-1174P-FD-US
Number of Relays: 10 pcs
Test: the variation of operating voltage is measured
based on cold start at 23°C, during which rated
voltage is applied to the coil with rated
contact current (5A), and left for 1
hour each under different
ambient
temperatures.
120% applied
110% applied
100% applied
−50 −40 −20 0 20 40 60 80 100
Rate of variability (%)
40
30
20
10
0
−10
−20
Rate of variability (%)
Ambient temperature (°C)
Sample: G6B-1174P-US
Test: the variation of operating voltage is measured
based on cold start at 23°C, during which rated
voltage is applied to the coil with rated contact
current (8A), and left for 1 hour
each under different ambient
temperatures.
40
30
20
10
0
−10
−20
120% applied
110% applied
100% applied
−50 −40 −20 0 20 40 60 80 100
Rate of variability (%)
Ambient temperature (°C)
Sample: G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
Test: the variation of operating voltage is
measured based on coil cold start at 23°C, during
which rated voltage is applied to the coil with rated
contact current (5A), and left
for 1 hour each under different
ambient temperatures.
40
30
20
10
0
−10
−20
120% applied
110% applied
100% applied
−50 −40 −20 0 20 40 60 80 100
1
6
34
0.90.85
10 max.
(9.8)*
10 max.
(9.8)*
20 max.
(19.9)*
Dimensions in pointed brackets < > are for the
Relay mounted to Socket.
0.5
(0.8)
(1.0)
0.3
0.9
0.5
3.5
0.5<0.4>
0.9<1.0>
0.9
<1.0>
0.85
<0.9>
0.3
3.5
0.5
10 max.
(9.8)*
20 max.
(19.9)*
* Average value
* Average value
(1.2)
(1.1)
10.16 7.62
2.54
2.54
Four, 1.1-dia. holes
Note: Orientation marks are indicated as follows:
Note: Check carefully the coil
polarity of the Relay. Polarity in
the parenthesis is the models for
reverse coil polarity.
10 max.
(9.8)*
3.2
1-pole Single-side Stable Models (SPST-NO(1a))
Straight PCB
G6B-1114P(-FD)(-1)-US
G6B-1184P-US
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Self-clinching PCB
G6B-1114C(-FD)-US