Datasheet
5
G6B PCB Power Relay
G
6
B
■Characteristics
Note 1. The values here are initial values.
2.The G6B-1177P(-FD)-ND model is flux-resistant. Do not wash it down with water.
*1. The contact resistance was measured with 1 A at 5 VDC using a voltage-drop method.
*2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was
measured.(Except the location between set/reset coil)
*3. This value was measured at a switching frequency of 120 operations/min.
Model
G6B-1114P(-FD)(-1)-US
G6B-1174P(-FD)(-1)-US
G6B-1114C(-FD)-US
G6B-1174C(-FD)-US
G6BU-1114P(-FD)(-1)-US
G6BU-1114C-US
G6BK-1114P(-FD)(-1)-US
G6BK-1114C(-FD)-US
G6B-1177P(-FD)-ND-US
G6B-1177C(-FD)-ND-US
G6B-1184P-US
G6B-2114P(-FD)(-1)-US
G6B-2214P(-FD)(-1)-US
G6B-2014P(-FD)(-1)-US
G6B-2114C(-FD)-US
G6B-2214C(-FD)-US
G6B-2014C(-FD)-US
Item Classification Single-side stable
Single-winding
latching
Double-winding
latching
Built-in operation indicator
& surge absorption diode
Single-side stable Single-side stable
Contact resistance *1 30 mΩ max. 50 mΩ max. 30 mΩ max.
Operate (set) time 10 ms max.
Release (reset) time 10 ms max.
Min. set pulse width − 15 ms (at 23°C) −
Min. reset pulse width − 15 ms (at 23°C) −
Insulation resistance *2 1,000 MΩ min.
Dielectric
strength
Between coil and
contacts
3,000 VAC, 50/60 Hz for 1 min
2,000 VAC,
50/60 Hz for 1 min
3,000 VAC, 50/60 Hz for 1 min
Between contacts
of the same polarity
1,000 VAC, 50/60 Hz for 1 min
Between contacts
of different polarity
−
2,000 VAC,
50/60 Hz for 1 min
Between set and
reset coils
−
250 VAC,
50/60 Hz for 1 min
−
Impulse withstand voltage
(between coil and contacts)
6 kV 1.2 × 50 μs 4.5 kV 1.2 × 50 μs 6 kV 1.2 × 50 μs − 6 kV 1.2 × 50 μs
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock
resistance
Destruction 1,000 m/s
2
Malfunction 100 m/s
2
300 m/s
2
100 m/s
2
Durability
Mechanical 50,000,000 operations min. (at 18,000 operations/hr)
Electrical 100,000 operation min. (at 1,800 operations/hr under rated load)
Failure rate (P level)
(reference value) *3
10 mA at 5 VDC 1 mA at 1 VDC 10 mA at 5 VDC
Ambient operating temperature -25°C to 70°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 3.5 to 4.6 g Approx. 3.5 g Approx. 3.7 g Approx. 5.4 g Approx. 3.5 g Approx. 4.5 g