Model Number Legend
SPST-NO Type Breaks 10-A Loads;
SPST-NO + SPST-NC Type Breaks
8-A Load
ROHS compliant
Compact: 20 x 15 x 10 mm (L x W x H).
Low power consumption: 200 mW.
Flux protection or fully sealed construction
available.
Unique moving loop armature reduces relay
size, magnetic interference, and contact
bounce.
Single- and double-winding latching types
also available
Rated coil voltage
Note: When ordering, add the rated coil voltage to the model number.
Example: G6C-1117P-US 12 VDC
G6C - - VDC
12345 6 7
1. Relay Function
None: Single-side stable
U: Single-winding latching
K: Double-winding latching
2. Contact Form
11: SPST-NO
21: SPST-NO + SPST-NC
3. Contact Type
1: Standard
4. Enclosure Ratings
7: Flux protection
4: Fully sealed
5. Terminals
P: Straight PCB
C: Self-clinching PCB
6. Approved Standards
US: UL/CSA certified
7. Rated Coil Voltage
3, 5, 6, 12, 24 VDC
Ordering Information
Classification Contact form Straight PCB Self-clinching PCB
Flux protection Fully sealed Flux protection Fully sealed
Single-side stable SPST-NO G6C-1117P-US G6C-1114P-US G6C-1117C-US G6C-1114C-US
SPST-NO + SPST-NC G6C-2117P-US G6C-2114P-US G6C-2117C-US G6C-2114C-US
SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US
SPST-NO + SPST-NC G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US
SPST-NO G6CK-1117P-US G6CK-1114P-US G6CK-1117C-US G6CK-1114C-US
SPST-NO + SPST-NC G6CK-2117P-US G6CK-2114P-US G6CK-2117C-US G6CK-2114C-US
Single-winding
latching
Double-winding
latching
PCB Power Relay – G6C
PCB Power Relay – G5CA
Power Relays
Installation
Make sure that sufficient space is provided between relays when
installing two or more relays side by side to facilitate heat
dissipation. Insufficient heat dissipation may result in the relay
malfunctioning.
Quick-connect Terminal Connections
Do not pass current through the PCB of the load
contactterminals (quick-connect terminals).
The terminals are compatible with Faston receptacle #187
and are suitable for positive-lock mounting.
Use only Faston terminals with the specified numbers. Select
leads for connecting Faston receptacles with wire diameters
that are within the allowable range for the load current. Do not
apply excessive force to the terminals when mounting or
dismounting the Faston receptacle.
Insert and remove terminals carefully one at a time. Do not insert
terminals on an angle, or insert/remove multiple terminals at the
same time.
The following positive-lock connectors made by AMP are
recommended. Contact the manufacturer directly for details on
connectors including availability.
Charged Terminals
The section marked with dotted circles (indicated by arrows) in
the following diagram includes the charged terminals of the relay.
When the relay is mounted on a PCB, make sure that there are no
metal patterns on the section of the PCB facing the portion of the
relay shaded in the following diagram.
Other Precautions
The G5CA is a power relay designed for applications switching
power loads such as heaters in electric household appliances.
Do not use the G5CA to switch micro loads less than 100 mA,
such as in signal applications.
Use fully sealed models if the relays will require washing.
Fluxprotection models may malfunction or the relay's
performance may be otherwise adversely affected if cleaning
fluid enters the relay.
Precautions
ALL DIMENSIONS SHOWN ARE IN MILLIMETRES.
To convert millimetres into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Precautions for Correct Use
Type Type Receptacle terminals (See note.) Positive housing
#187 terminals (width: 4.75 mm) AMP 170330-1 (170324-1) AMP 172074-1 (natural color)
AMP 170331-1 (170325-1) AMP 172074-4 (yellow)
AMP 170332-1 (170326-1) AMP 172074-5 (green)
AMP 172074-6 (blue)
Note: The numbers shown in parentheses are for air-feeding
CAT. No. J151-E2-02A-X