Datasheet
11
G6C PCB Power Relay
G
6
C
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
●Mounting
• Do not reverse the polarity of the coil
(+, −).
• When mounting more than two relays
side by side, keep the gap between
Relays as shown below to ensure a
good heat dissipation. It may result in
malfunction if heat is not dissipated
smoothly from the Relay.
●Sockets
• When mounting the Relay, make sure
to insert the Relay terminals
perpendicularly and correctly into the
socket contact pin.
• Hold-down clips (for mounting and
removal) are also available.
• The P6C model has a flux-resistant
construction. Do not wash it down with
water.
• The max. carry current of sockets is 5A.
●Double-winding Latching Circuit
• It is recommended to perform wiring of
No.1 and No.2 of the negative (-)
terminal as COM wiring, in order to
improve the operation stability for
Double-winding Latching.
●Using SPDT contact of the
SPST-NO+SPST-NC Relay
• Do not construct a circuit so that
overcurrent and burning occur if the
NO, NC and SPDT contacts are short-
circuited with the SPST-NO+SPST-NC
Relay. Arcing may generate short-
circuiting between contacts if there is
short-circuiting because of conversion
to the MBB contact caused by
asynchronous operation of the NO and
NC contacts, the interval between the
NO and NC contacts is small, or a
large current is left open.
●Other precautions
• This Relay is a Power Relay which is
suitable for power load switching. Do
not use the G6C for signal purposes
such as micro load switching under
10 mA.
Correct Use
2.54 mm ×
3 pitch min.
between
terminals
2.54 mm × 2 pitch min. between terminals
17 mm max. for sockets
7.5 mm
+
−
COM
8
(+)
S
1
+
−
7
R
2
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation sys
tems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be
sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K018-E1-07
0812(0207)(O)
Note: Do not use this document to operate the Unit.