Datasheet

59
Text
58
Text
PCB Power Relay – G6D
Power Relays
Model Number Legend
Ordering Information
Slim, Miniature Relay, Capable of
Relaying Programmable Controller
and Temperature Controller Outputs
ROHS compliant.
Slim and miniature: 17.5 x 6.5 x 12.5 mm
(L x W x H).
Ideal for high-density mounting
Switches 5 A at 250 VAC/30 VDC.
Allows 300,000 operations with a 2-A load at
250 VAC or 30 VDC.
Actual load switching capability equals the
G6B’s capability.
Washable construction.
RCE
Classification Contact form Enclosure ratings Model
Standard SPST-NO Fully sealed G6D-1A-ASI
Accessories (Order Separately)
Connecting Socket P6D-04P
Rated coil voltage
Note: When ordering, add the rated coil voltage to the model number.
Example: G6D-1A-ASI 12 VDC
G6D - - VDC
1 2 3 4
1. Number of Poles
1: 1 pole
2. Contact Form
A: SPST-NO
3. Contact Material
ASI: Silver alloy (cadmium-free)
4. Rated Coil Voltage
5, 12, 24 VDC
PCB Power Relay – G6M
Precautions
BASIC INFORMATION
Before actually committing any component to a mass-
productionsituation, OMRON strongly recommends situational
testing, in as close to actual production situations as possible.
One reason is to confirm that the product will still perform as
expected after surviving the many handling and mounting
processes involved in mass production. Also, even though
OMRON relays are individually tested a number of times, and
each meets strict requirements, a certain testing tolerance is
permissible. When a high-precision product uses many
components, each depends upon the rated performance
thresholds of the other components. Thus, the overall
performance tolerance may accumulate into undesirable levels.
To avoid problems, always conduct tests under the actual
application conditions.
General
To maintain the initial characteristics of a relay, exercise care
that it is not dropped or mishandled. For the same reason, do not
remove the case of the relay; otherwise, the characteristics may
degrade. Avoid using the relay in an atmosphere containing
sulfuric acid (SO
2
), hydrogen sulfide (H
2
S), or other corrosive
gases.
Do not continuously apply a voltage higher than the rated
maximum voltage to the relay. Never try to operate the relay at a
voltage and a current other than those rated.
Do not use the relay at temperatures higher than that specified in
the catalog or data sheet.
Engineering Data
Dimensions
ALL DIMENSIONS SHOWN ARE IN MILLIMETRES.
To convert millimetres into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
CAT. No. K121-E2-03A-X
Omron 08 Cat 1-302 5/10/07 15:39 Page 58