Datasheet
61
Text
60
Text
PCB Power Relay – G6D
Maximum Switching Power Ambient Temperature vs.
Maximum Coil Voltage
Ambient Temperature vs.
Operating/Recovery Voltage
G6D-1A-ASI
Endurance
Note: The maximum coil voltage is the
maximum voltage that can be
applied to the relay coil
Malfunctioning Shock
G6D-1A-ASI
30
10
5
3
1
0.1
0 3 5 10 30 100 250 500 1,000 0 233040 50 6070 8090
0.3
0.5
50
DC resistive
load
DC inductive
load
Sample: G6D1A
Quantity: 5
Operating voltage
Recovery voltage
max.
Y
Y
XX'
Z
Z'
Y'
1,000
800
600
400
200
206
Energized
Unit: m/s
2
Not energized
X
Z'
Z
X'
Shock direction
Coil terminals
Y'
min.
X
max.
min.
X
AC inductive
load
cosφ=0.4
AC resistive load
Switching current (A)
80
60
0
20
40
100
Operating/recovery voltage (ratio of rated voltage) (%)
180
160
140
120
80
60
100
200
Maximum coil voltage (%)
Switching voltage (V)
−40 −20 0 20 40 60 80
Ambient temperature (°C)
Ambient temperature (°C)
Measurement conditions: Impose a shock in the
±X, ±Y, and ±Z directions three times each with
the Relay energized to check the shock values
that cause the Relay to malfunction.
Endurance (x10
4
operations)
Switching current (A)
1 2 3 4 5 6 7 8 9 10
500
300
100
50
30
10
5
3
0
250-VAC/30-VDC resistive load
250-VAC/30 VDC inductive load
(cosφ=0.4/ L/R=7 ms)
Engineering Data
■
Approved Standards
The rated values approved by each of the safety standards may be different from the performance characteristics individually defined
in this catalogue.
UL Approval (File No. E41515) UL508
Model Number of poles Coil ratings Contact Ratings Number of test operations
G6D-1A-ASI 1 5 to 24 VDC 5 A, 250 VAC (General Use) 6,000
5 A, 30 VDC
CSA Approval (File No. LR31928) C22.2 No. 14
Model Number of poles Coil ratings Contact Ratings Number of test operations
G6D-1A-ASI 1 5 to 24 VDC 5 A, 250 VAC (General Use) 6,000
5 A, 30 VDC (Resistive)
EN/TÜV Approval (Registration No. R50029064/EN61810-1)
Model Number of poles Coil ratings Contact Ratings Number of test operations
G6D-1A-ASI 1 5, 12, 24 VDC 5 A, 250 VAC (cosϕ = 1.0) 70,000
5 A, 30 VDC (0 ms)
Power Relays
PCB Power Relay – G6D
■
Characteristics
Contact resistance 100 mΩ max.
Operate time 10 ms max.
Release time 5 ms max.
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 3,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage 6KV 1.2x50µsec (between coil and contacts)
Creepage (Typ) 4.5 mm
Clearance (Typ) 4.5 mm
Tracking Resistance CTI) 100 V
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance Destruction: 1,000 m/s
2
Malfunction: 100 m/s
2
Endurance Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 70,000 operations min. (5 A at 250 VAC/30 VDC, resistive load)
300,000 operations min. (2 A at 250 VAC/30 VDC, resistive load)
Ambient temperature Operating: -25˚C to 70˚C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 3 g
Rated voltage 5 VDC 12 VDC 24 VDC
Rated current 40 mA 16.7 mA 8.3 mA
Coil resistance 125 Ω 720 Ω 2,880 Ω
Must operate voltage 70% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 160% of rated voltage (at 23°C)
Power consumption Approx. 200 mW
Note: The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down.
Specifications
■
Coil Ratings
■
Contact Ratings
Rated load 5 A at 250 VAC, 5 A at 30 VDC, resistive load
Contact material AgSnln
Rated carry current 5 A
Max. switching voltage 250 VAC, 30 VDC
Max. switching current 5 A
Max. switching power 1,250 VA, 150 W
Failure rate (reference value) 10 mA at 5 VDC
Note: P level: λ
60
= 0.1 x 10
-6
/operation.
Insulation
Distance
Omron 08 Cat 1-302 5/10/07 15:39 Page 60