Datasheet
63
Text
62
Text
Power Relays
Text
Slim, Miniature Relay with 1-pole 5-
A Switching Capability
■
Slim 5-mm width and miniature size.
(21.3 x 5.08 x 12.5 mm max.)
■
Ideal for high-density mounting.
■
Delivers high switching performance (5 A at
250 VAC/30 VDC) and enables various loads
all in a slim, miniature size.
■
Highly sensitive coil type (120 mW) also
available.
■
Satisfies EN 61131-2 (PLC) and EN 61010
(measuring instrument/control equipment)
reinforced insulation requirement.
■
Special socket also added to the series.
Applications:
PLCs, I/O modules, I/O ports, Timers,
Temperature Controllers, and Control Boards.
■
Coil Ratings
■
Accessories (Order Separately)
Item Standard High-sensitivity
Rated voltage 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC
Rated current 36 mA 15 mA 7.5 mA 24 mA 10 mA 5 mA
Coil resistance 139Ω 800Ω 3,200Ω 208Ω 1,200Ω 4,800Ω
Must operate voltage 70% max. of rated voltage
Must release voltage 5% min. of rated voltage
Max. voltage 160% of rated voltage (at 23˚C)
Power consumption Approx. 180 mW Approx. 120 mW
Connecting Socket P6DS-04P
Relay Pullout Tool R99-01 for G6DS
Classification Contact form Enclosure ratings Model
Standard SPST-NO Fully sealed G6DS-1A
High-sensitivity G6DS-1A-H
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23˚C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23˚C.
3. “Max. voltage” refers to the maximum voltage that can be applied to the relay coil. It is not the maximum voltage that can
be applied continuously.
PCB Power Relay - G6DS
RoHS Compliant
Rated coil voltage
Note: When ordering, add the rated coil voltage to the model number.
Example: G6DS-1A 12 VDC
G6DS- VDC
12 3
1. Number of Poles
1: 1 pole
2. Contact Form
A: SPST-NO
3. Classification
None: Standard
H: High-sensitivity
-
4
4. Rated Coil Voltage
5, 12, 24 VDC
Ordering Information
PCB Power Relay – G6D
More than two relays can be closely mounted right side up as
shown in the following illustration.
More than two relays can be closely mounted upside down as
shown in the following illustration.
Note: The space between each relay required for heat radiation
may vary with operating conditions. Contact your OMRON
representative for details
SOCKET MOUNTING HEIGHT
When mounting the relay, insert it into the socket as vertically as
possible so that the relay terminals contact securely with the
contact pins on the socket.
The P6D is flux-resistive. Do not wash the P6D with water.
Dismount the relay from the socket before soldering the socket to
a PCB.
Current flow:
5 A max.
6.5 mm
7.62 mm in the
upside-down
direction
1.12 mm
Current flow:
2 A max.
18.5 mm max.
Precautions
G6D-1A-ASI
Terminal Arrangement/
Internal Connections
(Bottom View)
Mounting Holes
(Bottom View)
Tolerance: ±0.1
P6D-04P Socket
0.5
17.5 max.
2.54
0.3
3.5
5.08
0.8
5.08
0.5
(17.3)*
6.5 max.
(6.4)*
2.54
3.6
10.8
0.65
0.3
5.0876.2
19.7 max.
6.9 max.
(6.7)*
6+0.1
(19.5)*
1
13
57
(1.13)
(0.71)
2.54
2.54
15.24
5.08
(2.18)
(0.86)
2.54
2.54
15.24
5.08
Mounting Holes
(Bottom View)
Tolerance: ±0.1
Four, 1.1-dia.
holes
Four, 1.1-dia.
holes
*Average value
*Avera
g
e value
12.5 max.
(12.4)*
7.62.
Dimensions
Note: 1. All units are in millimetres unless otherwise indicated.
2. Orientation marks are indicated as follows:
ALL DIMENSIONS SHOWN ARE IN MILLIMETRES.
To convert millimetres into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
CAT. No. K127-E2-02A-X