Datasheet

2
G6DN PCB Power Relay
G
6
D
N
Characteristics
Note 1. Values in the above table are initial values.
Note 2. The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method.
Note 3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 500 VDC.
* This value was measured at a switching frequency of 120 operations/min.
Standard High durability General purpose
Contact resistance 100 mΩ max.
Operate time 10 ms max.
Release time 5 ms max.
Insulation resistance 1,000 M
Ω
min. (at 500 VDC)
Dielectric strength
Between coil and
contacts
3,000 VAC, 50/60 Hz for 1 min
Between contacts of
the same polarity
750 VAC, 50/60 Hz for 1 min
Surge withstand
voltage
Between coil and
contacts
6 kV (1.2 50 μs)
Vibration resistance
Destruction 10 to 55 to 10 Hz, 2.5 mm single amplitude (5.0 mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance
Destruction 1,000 m/s
2
Malfunction 100 m/s
2
Durability
Mechanical 20,000,000 operations min. (at 18,000 operations/hr)
Electrical
100,000 operations min.
(3 A at 250 VAC,
3 A at 30 VDC Resistive load)
80,000 operations min.
(5 A at 250 VAC,
5 A at 30 VDC Resistive load)
100,000 operations min.
(2 A at 250 VAC,
2 A at 30 VDC Inductive load)
100,000 operations min.
(5 A at 250 VAC, Resistive load)
100,000 operations min.
(5 A at 30 VDC, Resistive load)
200,000 operations min.
(2 A at 250 VAC, Inductive load)
200,000 operations min.
(2 A at 30 VDC, Inductive load)
50,000 operations min.
(5 A at 250 VAC, Resistive load)
50,000 operations min.
(5 A at 30 VDC, Resistive load)
100,000 operations min.
(2 A at 250 VAC, Inductive load)
100,000 operations min.
(2 A at 30 VDC, Inductive load)
Failure rate (P level) (reference value) * 0.1 mA at 0.1 VDC
Ambient temperature Operating -40°C to +90°C (with no icing or condensation)
Humidity 5% RH to 85% RH
Weight Approx. 3 g