Datasheet
4
G6DN PCB Power Relay
G
6
D
N
■Approved Standards
●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined
in this datasheet.
UL/C-UL-approved models (File No. E41515)
Note. CSA certification CSA 22.2 No.14 can be recognized by C-UL.
VDE (EN61810-1) (Certificate No. 40042696)
TÜV (EN61810-1) (Registration No. R 50396359)
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
Model Contact form Coil ratings Contact ratings Operations
G6DN-1A(-SL) SPST-NO 4.5 to 24 VDC
5 A at 277 VAC (Resistive) 95°C 6,000
5 A at 30 VDC (Resistive) 90°C 6,000
3A, 250V ac, Resistive 85°C 100,000
1/10 hp 125 VAC 95°C 1,000
1/10 hp 277 VAC 95°C 1,000
D300 120 VAC/240 VAC 95°C 6,000
C300 120 VAC/240 VAC 95°C 6,000
R300 125 VDC/250 VDC 95°C 6,000
G6DN-1A-L SPST-NO 5 to 24 VDC
5 A 250 VAC (Resistive) 95°C 100,000
2 A 250 VAC (General Use) 95°C 100,000
2 A 30 VDC (General Use) 95°C 100,000
1/10 hp 120 VAC 40°C 6,000
C300 120 VAC/240 VAC 95°C 6,000
D150 120 VAC 95°C 6,000
R150 125 VDC 95°C 6,000
Model Contact form Coil ratings Contact ratings Operations
G6DN-1A SPST-NO 4.5, 5, 12, 24 VDC
5 A at 250 VAC (cosφ= 1.0) 90°C 10,000
5 A at 30 VDC (L/R = 0 ms) 90°C 10,000
G6DN-1A-L SPST-NO 5, 12, 24 VDC
5 A 250 VAC (cosφ= 1.0) 90°C 100,000
2 A 250 VAC (cosφ= 0.4) 90°C 100,000
2 A 250 VAC (cosφ= 0.6) 90°C 100,000
5 A 30 VDC (L/R = 0 ms) 90°C 100,000
2 A 30 VDC (L/R = 7 ms) 90°C 100,000
Model Contact form Coil ratings Contact ratings Operations
G6DN-1A-SL SPST-NO 5, 12, 24 VDC
5 A at 250 VAC (cosφ= 1.0) 90°C 10,000
5 A at 30 VDC (L/R = 0 ms) 90°C 10,000
Clearance distance 3.5 mm min.
Creepage distance 3.6 mm min.
Type of insulation coil-contact circuit
open contact circuit
Basic (PD.2)
Micro disconnection
Rated Insulation voltage 300 V
Pollution degree 2
Rated voltage system 250 V
Over voltage category II
Category of protection according to IEC 61810-1 RT III (Sealed)
Insulation material group I
Tracking resistance according to IEC 60112 CTI 600 V min.
Flammability class according to UL94 V-0
Coil insulation system according to UL Class B