Datasheet
3
G6QE PCB Power Relays
G
6
Q
E
Dimensions
Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually confirm the
values before use.
UL/C-UL (CSA) Recognized
(File No. E41515) CQC certified: (Certificate No.CQC18002192007)
EN/IEC, TÜV Certified: (Certificate No.R50407379)
Precautions
• Please refer to "PCB Relays Common Precautions" for correct use.
Coil Voltage Reduction (Holding Voltage) after Relay
Operation
• If the coil voltage is reduced to the holding voltage after Relay
operation, first apply the rated voltage to the coil for at least
100 ms, as shown below.
• A voltage of at least 35% of the rated voltage is required for
the coil holding voltage. Do not allow voltage fluctuations to
cause the coil holding voltage to fall below this level.
* The coil resistance were measured at a coil temperature of 23°C with
tolerances of ± 10%.
Other Precautions
• This Relay is suitable for power load switching of air-
conditioning compressors and power supplies, etc. Do not use
this Relay to switch micro loads less than 100 mA, such as in
signal applications.
4
3
21
20.5 MAX.
3.5
2-1.5
16 MAX.
2-0.6 SQUARE
2-0.8
30.5 MAX.
6.25
±0.1
5.75
±0.1
22
±0.1
12
±0.05
27.6
±0.1
2-1.8
+0.1 dia.
0
2-1.3
+0.1 dia.
0
G6QE-1A
PCB Mounting Holes
(BOTTOM VIEW)
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
(No coil polarity)
Model Coil ratings Contact ratings
Number of
test
operations
G6QE-1A 5 to 24 VDC 36 A 277 VAC (Resistive) 85°C 10,000
G6QE-1A 5 to 24 VDC 32 A 277 VAC (Resistive) 40°C 50,000
G6QE-1A 5 to 24 VDC 30 A 277 VAC (Resistive) 40°C 100,000
Model Coil ratings Contact ratings
Number of
test
operations
G6QE-1A 5, 12, 24 VDC 36 A 277 VAC (Resistive) 85°C 10,000
G6QE-1A 5, 12, 24 VDC 32 A 277 VAC (Resistive) 40°C 50,000
G6QE-1A 5, 12, 24 VDC 30 A 277 VAC (Resistive) 40°C 100,000
Model Coil ratings Contact ratings
Number of
test
operations
G6QE-1A 5, 12, 24 VDC 36 A 277 VAC (cosφ=1) 85°C 10,000
G6QE-1A 5, 12, 24 VDC 32 A 277 VAC (cosφ=1) 40°C 50,000
G6QE-1A 5, 12, 24 VDC 30 A 277 VAC (cosφ=1) 40°C 100,000
Correct Use
Applied coil voltage Coil resistance*
Power
consumption
Rated voltage 100% 17.9Ω (5 VDC)
102.9Ω (12 VDC)
411.4Ω (24 VDC)
Approx.1400 mW
Holding voltage 35% Approx.172 mW
35%
(Holding voltage)
100%
(Rated voltage)
100ms min.