Datasheet

3
G6QE PCB Power Relays
G
6
Q
E
Dimensions
Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually confirm the
values before use.
UL/C-UL (CSA) Recognized
(File No. E41515) CQC certified: (Certificate No.CQC18002192007)
EN/IEC, TÜV Certified: (Certificate No.R50407379)
Precautions
• Please refer to "PCB Relays Common Precautions" for correct use.
Coil Voltage Reduction (Holding Voltage) after Relay
Operation
If the coil voltage is reduced to the holding voltage after Relay
operation, first apply the rated voltage to the coil for at least
100 ms, as shown below.
A voltage of at least 35% of the rated voltage is required for
the coil holding voltage. Do not allow voltage fluctuations to
cause the coil holding voltage to fall below this level.
* The coil resistance were measured at a coil temperature of 23°C with
tolerances of ± 10%.
Other Precautions
This Relay is suitable for power load switching of air-
conditioning compressors and power supplies, etc. Do not use
this Relay to switch micro loads less than 100 mA, such as in
signal applications.
4
3
21
20.5 MAX.
3.5
2-1.5
16 MAX.
2-0.6 SQUARE
2-0.8
30.5 MAX.
6.25
±0.1
5.75
±0.1
22
±0.1
12
±0.05
27.6
±0.1
2-1.8
+0.1 dia.
0
2-1.3
+0.1 dia.
0
G6QE-1A
PCB Mounting Holes
(BOTTOM VIEW)
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
(No coil polarity)
Model Coil ratings Contact ratings
Number of
test
operations
G6QE-1A 5 to 24 VDC 36 A 277 VAC (Resistive) 85°C 10,000
G6QE-1A 5 to 24 VDC 32 A 277 VAC (Resistive) 40°C 50,000
G6QE-1A 5 to 24 VDC 30 A 277 VAC (Resistive) 40°C 100,000
Model Coil ratings Contact ratings
Number of
test
operations
G6QE-1A 5, 12, 24 VDC 36 A 277 VAC (Resistive) 85°C 10,000
G6QE-1A 5, 12, 24 VDC 32 A 277 VAC (Resistive) 40°C 50,000
G6QE-1A 5, 12, 24 VDC 30 A 277 VAC (Resistive) 40°C 100,000
Model Coil ratings Contact ratings
Number of
test
operations
G6QE-1A 5, 12, 24 VDC 36 A 277 VAC (cosφ=1) 85°C 10,000
G6QE-1A 5, 12, 24 VDC 32 A 277 VAC (cosφ=1) 40°C 50,000
G6QE-1A 5, 12, 24 VDC 30 A 277 VAC (cosφ=1) 40°C 100,000
Correct Use
Applied coil voltage Coil resistance*
Power
consumption
Rated voltage 100% 17.9Ω (5 VDC)
102.9Ω (12 VDC)
411.4Ω (24 VDC)
Approx.1400 mW
Holding voltage 35% Approx.172 mW
35%
(Holding voltage)
100%
(Rated voltage)
100ms min.