Electrical Endurance Data
Endurance Under Real Load
G6RL-1(A)-ASI-PL
Note: The results shown reflect values measured using very sever test conditions, i.e., Duty: 1 s ON/OFF.
Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed
information for the electrical endurance under your test conditions.
G6RL-1(A) 8 A at 250 VAC (cos
φ = 1) NO 50,000 operations min.
8 A at 250 VAC (cos
φ = 1) NC 50,000 operations min.
5 A at 24 VDC 50,000 operations min.
G6RL-1(A)-(SR)-ASI-(PL) 10 A at 250 VAC (cos
φ = 1) NO 100,000 operations min.
8 A at 250 VAC (cos
φ = 1) 100,000 operations min.
5 A at 30 VDC 50,000 operations min.
G6RL-1(A)4-ASI 8 A at 250 VAC (cos
φ = 1) NO 50,000 operations min.
8 A at 250 VAC (cos
φ = 1) NC 50,000 operations min.
5 A at 24 VDC 50,000 operations min.
G6RL-14-SR-ASI 8 A at 250 VAC (cos
φ = 1) NO 50,000 operations min.
3 A at 250 VAC (cos
φ = 1) NC 100,000 operations min.
5 A at 24 VDC NO 50,000 operations min.
5 A at 24 VDC NC 30,000 operations min.
(Reference Only)
Rated voltage Condition Frequency Electrical life
230 VAC P1 load (2
× 200 W lamps parallel to ignition transformer) 1.5 s ON/4.5 s OFF 250,000 operations