4
G9TB AC Power Latching Relay
G9TB
Note 1. Relay is delivered as "set" status unless specified otherwise. However, the status may change due to the shock from transportation or mounting operations.
Therefore, it is recommended the relay should be set to the expected status via a power supply before being used.
Note 2. In order to maintain "set" or "reset" status, the energizing voltage to coil & the pulse width shouldn't lower then the rated value.
Note 3. Do not energize both of set and reset coil simultaneously.
Note 4. Energizing time longer than 1,000 ms should be avoided.
Engineering Data
Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values
before use.
UL Recognized: (File No. E41515)
Maximum Switching Capacity
G9TB-U1A -E
G9TB-K1A -E
Model Contact form Coil ratings Contact ratings Number of test operations
G9TB-U1ATH-E
G9TB-U1ATW-E
G9TB-K1ATW-E
G9TB-K1ATH-E
SPST-NO (1a) 12V DC
120 A, 277 V AC (Resistive) 70°C 6,000
100 A, 277 V AC (Resistive) and then 100 A,
277 V (PF=0.5), 10 sec. ON / 20 sec. OFF,
40°C
5,000 for resistive and then
5,000 for PF=0.5
G9TB-K1ATW-E
1
10
100
1000
1101001000
Switching current (A)
Switching voltage(V)
276
Switching voltage(V)
1
10
100
1000
1101001000
Switching current (A)
120
276
AC Resistive Load
AC Inductive Load (PF=0.5)