Datasheet

6
VX Miniature Basic Switch
V
X
Precautions
Please refer to "Common Precautions" for correct use.
Handling
Do not apply excessive shock. Doing so may cause damage to
the Switch's internal components because it is designed for a
small load.
Soldering
Terminal connections
Complete the soldering at the iron tip temperature between
250 to 350°C (60W) within 5 seconds, and do not apply any
external force for 1 minute after soldering.
Apply minimum amount of flux required. It may result in
contact failure once the flux penetrates into the internal part of
the Switch.
Connecting to Tab Terminals (#187)
When connecting to the Tab terminal, insert the receptacle of
tab #187 straight toward the terminal.
Applying excessive external force laterally may cause
deformation of terminals and may damage the housings.
Mounting
Use M3 mounting screw with plane washers or spring washers to
securely mount the Switch. Tighten the screws to a torque of
0.39 to 0.59 N·m {4 to 6 kgf·cm}.
Mounting Direction
For a Switch with an actuator, mount the Switch in a direction
where the actuator weight will not be applied to the Switch.
Since the Switch is designed for a small load, its resetting force
is small. Therefore, resetting failure may occur if unnecessary
load is applied to the Switch.
Using Micro Loads
Using a model for ordinary loads to open or close the contact of
a micro load circuit may result in faulty contact. Use models that
operate in the following range. However, even when using micro
load models within the following operating range, if inrush current
occurs when the contact is opened or closed, it may increase the
contact wear and so decrease durability. Therefore, insert a
contact protection circuit where necessary. The N-level reference
value applies for the minimum applicable load. This value
indicates the malfunction reference level for the reliability level of
60% (λ
60).
(JIS C5003)
The equation, λ
60=0.5×10
-6
/operations operation, indicates that
the estimated malfunction rate is less than operations
with a reliability level of 60%.
Cautions Correct Use
1
2,000,000
30
24
12
5
0
1 10 100 1,000
Current (mA)
0.1
1 mA
Operating
range for
general-load
model
VX-5
Operating range for
micro-load model
VX-01
26 mA0.16 mA
100 mA 160 mA
100 mA
Voltage (V)