Emergency Stop Pushbutton Switches A22NE-PD/A22NE-P/A22E Series Securing Greater Safety A variety of functions for enhanced safety and mounting efficiency Coming soon Basic: Screw Terminal Block Types Vibration-resistant: Push-In Plus Terminal Block Types Push-In Plus Terminal Block + Lock-lever-linked Contact Types A22E Series A22NE-P Series A22NE-PD Series
| Emergency Pushbutton Switch A22NE-PD/A22NE-P/A22E Series Machines Are Designed to Stop Without Fail. An emergency stop pushbutton switch stops machine equipment in an emergency to protect the safety of workers. However, if the switch does not function properly due to human error, malfunction, defective wiring or other reasons, it will lead to a major accident. That is why Omron has focused on stopping machines without fail and produced a lineup of emergency stop switches with enhanced functionality.
| 3 Three Functions to Enhance Reliability Stops machines when a Switch is improperly mounted. ・Cuts off the current when the lock lever is off. ・Instantly detects work errors and lever damage. Lock-lever-linked Contacts Refer to page STO STOP 4 for details. Reduces loose and detached wiring. ・Wires are resistant to vibration and do not come off easily. ・Reduces work for wiring and maintenance. Push-In Plus Terminal Block Refer to page 5 for details. Stable operation in harsh environments.
| Emergency Pushbutton Switch A22NE-PD/A22NE-P/A22E Series Accident Prevention/Stable Operation Suppress Malfunctions Throughly with Functions for Various Applications. Lock-lever-linked Contacts Operation unit A22NE-PD Series * Lock lever (ON state) Detects Improper Installations for Zero Switch unit Malfunction Problems During Emergencies If the sliding operation of the lock lever is insufficient, the operation unit may not function properly when needed, even if pushed.
| 5 Push-In Plus Terminal Block A22NE-PD*/A22NE-P Series Prevents Loose and Detached Wiring Caused by Vibration During Operation In addition to preventing unexpected stoppages caused by disconnection, it is also possible to reduce maintenance efforts. Also help reduce the wiring work IEC standard Push-In Plus Terminal (Cable diameter) Block Just insert wires like you would into an earphone jack. No tools are required. They help reduce the time and work involved in wiring. 20 N min (AWG20, 0.
Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22NE-PD A22NE-PD/A22NE-P/A22E Install in 22-dia. or 25-dia. Panel Cutout (When Using a Ring) A22NE-P • Direct opening mechanism to open the circuit when the contact welds. • With a latching mechanism to prevent operating errors. • Lock lever for easily mounting and removing the Unit. • Use 25-dia. ring to install in 25-dia. panel cutouts.
Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) Push-in Plus Terminal Block Models With Lock-lever-linked Contact Function A22NE-PD A22NE-PD Install in 22-dia. or 25-dia. Panel Cutout For the most recent information on models that have been certified for safety standards, refer to your OMRON website. A22NE-P (When Using a Ring) • The small size of the control panel is realized by conserving space and changing the direction of the wiring.
A22NE-PD A22NE-PD Ordering Information List of Models (Completely Assembled) Non-lighted Models (Without EMO/EMS Indication) Appearance Degree of Protection Contact configuration * Operation 40-dia. head Medium Pull-reset A22NE-MP-PD@@-N IP65 oil-resistant models A22NE-P 40-dia. head Medium Pull-reset A22NE-MP-PD@@-N-69K IP69K 30-dia. head Small Turn-reset A22NE-S-PD@@-N IP65 oil-resistant models A22E 40-dia. head Medium Turn-reset A22NE-M-PD@@-N IP65 oil-resistant models 60-dia.
A22NE-PD Operation Unit Non-lighted Size Function Small (30 dia.) Medium (40 dia.) Degree of protection Large (60-dia.
A22NE-PD A22NE-PD Specifications Certified Standard Ratings Certified Standards • UL508 (File No. E76675), CSA C22.2 No.14 5 A at 125 VAC, 3 A at 250 VAC B300 • TÜV (EN60947-5-1) - Certified direct opening (EN60947-5-5) AC-15 3 A at 125 VAC DC-13 1 A at 30 VDC • CCC (GB14048.5) AC-15 3 A at 125 VAC DC-13 1 A at 30 VDC Certification body Standards File No. UL * UL508, C22.2 No.14 E76675 TÜV SÜD EN60947-5-1 Consult your OMRON (Certified direct opening), representative for details.
A22NE-PD Operation Item Allowable operating Mechanical frequency Electrical Turn-reset Pull-reset Non-lighted model Lighted Model Non-lighted model Non-lighted model (Models with IP69K) A22NE-@-PD@@-N-@ A22NE-M-PD@@-C-@ A22NE-MP-PD@@-N-@ A22NE-MP-PD@@-N-69K 30 operations/minute or less (One operation consists of set and reset operations.) 30 operations/minute or less (One operation consists of set and reset operations.) Insulation resistance *1 100 MΩ min.
A22NE-PD A22NE-PD Terminal Arrangement (BOTTOM VIEW) Non-lighted A22NE-P One contact (1NC) Two contacts (2NC) Three contacts (3NC) Two contacts (1NC + 1NO) Three contacts (2NC + 1NO) Four contacts (3NC + 1NO) Four contacts (4NC) Lighted Terminal arrangement A22E The switch terminal is same as that in the non-lighted models. Indicates the terminals for lighting (X1-X2). (Example: Four contacts (4NC) Lighted models) Lock lever Terminal (insertion) hole 3.9 (0.3) 36.3 (0.3) 3.9 11 3.
A22NE-PD Operation Unit Color: Red Non-lighted LED lighting A22NE-PD Structure and Nomenclature Lamp Light source • LED Lamp } A22NE-P Switch Mounting Latches Switch Blocks Lighting unit Contact Ratings 3 A at 250 VAC 5 A at 125 VAC Lighting Method Non-lighted Lighted (LED) A22E Common Accessories and Tools Common Note 13
A22NE-PD A22NE-PD Dimensions (Unit: mm) Non-lighted Models A22NE-MP-PD@@-N A22NE-MP-PD@@-N-69K Pull-reset (40-dia.) Degree of Protection: IP65 oil-resistant models Pull-reset (40-dia.) Degree of Protection: IP69K 40 dia. 45 40 dia. 45 1.8 5.9 54.7 1.8 (0.5) 32 A22NE-P 5.9 55 32 A22NE-S-PD@@-N A22NE-M-PD@@-N Small Turn-reset (30-dia.) Degree of Protection: IP65 oil-resistant models Medium Turn-reset (40-dia.) Degree of Protection: IP65 oil-resistant models 45 40 dia. 45 30 dia. 1.
A22NE-PD Mounting to the Panel (1) Preparing the Panel (3) Mounting the Operation Unit on the Panel Panel hole dimension and panel thickness • If outer surface treatment such as coating is performed for the panel, the panel dimensions after outer surface treatment must meet the specified panel dimensions. Panel hole dimension Panel thickness 22.3 dia. 1 to 5 mm 22.3 +0.4 0 • Do not tighten the Tightening Nut more than necessary using tools such as pointed-nose pliers.
A22NE-PD A22NE-PD Removing the Switch Unit Installing the LED Lamp (Lighted Models) When the Switch Unit is to be Removed When the LED Lamp is to be Installed Slowly push the release port (concave part) of the lock lever with a screwdriver to release the lock. The lock lever moves to the release position. Insert the protrusions on the LED Lamp into the guides on the Switch Unit in direction (1), and then turn the LED Lamp in direction (2) to lock it in place.
A22NE-PD Be sure to read the precautions for All PushButton Switches in the website at: http://www.ia.omron.com/. Indication and Meaning for Safe Use Warning Indicates a potentially hazardous situation that, if not avoided, could result in serious injury or death. Additionally there may be significant property damage. Comments on what to do or avoid doing, to use the product safely.
A22NE-PD A22NE-PD A22NE-P A22E • After storing the product for a long time exceeding 1 year, perform, at a minimum, inspections of the operating characteristics, contact resistance, insulation resistance, and dielectric strength as well as evaluate the product under the working conditions. • This product is intended for indoor use only. Using the product outdoors will result in failure. • Do not wire anything to the release holes.
A22NE-PD 2. Removing Wires from the Push-In Plus Terminal Block 3. Recommended Ferrules and Crimp Tools Coating peeling amount Recommend Wire Type Stripping length (Ferrules not used) 0.25 to 1.5 mm2/AWG 24 to AWG 16 8 mm Recommended ferrules Applicable wire (mm2) 0.25 0.34 24 22 (2) Approx. 10 to 15° (1) 0.5 20 0.75 18 (3) Flat-head screwdriver Recommended ferrules Ferrule Stripping conductor length (mm) length (Ferrules not (AWG) (mm) used) 1/1.25 18/17 1.25/1.
A22NE-PD A22NE-PD LED Lamps • A current-limiting resistor is built in the LED lamp, so the installation of an external resistance is not required. • Lighting malfunction of the LED lamp A micro-current of approximately 0.1 mA or less is sufficient to turn on the LED lamps. Take a countermeasure like adding a resistor to prevent mis-lighting in parallel to the LED lamp. The micro-current varies with the machine (leak current or stray capacity between cables, etc.).
Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) Push-in Plus Terminal Block Models A22NE-PD A22NE-P Install in 22-dia. or 25-dia. Panel Cutout For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Be sure to read the "Safety Precautions" on pages 33 and 56. A22NE-P (When Using a Ring) • The small size of the control panel is realized by conserving space and changing the direction of the wiring.
A22NE-P A22NE-PD Ordering Information List of Models (Completely Assembled) Non-lighted Models Appearance Degree of Protection Contact configuration * Operation 40-dia. head Medium Pull-reset A22NE-MP-P@@2-N IP65 oil-resistant models A22NE-P 40-dia. head Medium Pull-reset A22NE-MP-P@@2-N-69K IP69K 30-dia. head Small Turn-reset A22NE-S-P@@2-N 40-dia. head Medium Turn-reset A22NE-M-P@@2-N IP65 oil-resistant models A22E 60-dia.
A22NE-P them in combination for models that are not available as assembled Units. These can also be used as inventory for maintenance parts. Non-lighted Lighted Operation Unit A22NE-PD Subassembled ........ The Operation Unit, LED Lamp, Mounting Latches, Switch Blocks, and Lighting Unit can be ordered separately. Use Operation Unit A22NE-P Mounting Latches Push-in Plus Terminal Block Push-in Plus Terminal Block Common Note * Up to three Switch Blocks can be mounted for multiple contacts.
A22NE-P A22NE-PD Operation Unit Non-lighted Size Function Small (30 dia.) Medium (40 dia.) Sealing capability Large (60-dia.) Single item order model A22NE-MP-N IP65 oil-resistant models --- --- Pull-reset A22NE-P A22NE-MP-N-69K IP69K --- --- A22NE-M-N A22NE-MRO-N A22NE-MRO-N-RD A22E A22NE-S-N Turn-reset A22NE-L-N IP65 oil-resistant models A22NE-MRS-N A22NE-MRS-N-RD Common Accessories and Tools Lighted Size Function Sealing capability Medium (40 dia.
A22NE-P A22NE-PD Accessories (Order Separately) Item Appearance Contact specifications 1NO (Blue) Standard load A22NZ-S-P1AN 1NC (Red) Standard load A22NZ-S-P1BN 2NC (Red) Standard load A22NZ-S-P2BN Switch Blocks (one contact) Switch Blocks (two contacts) Mounting Latches Provided as standard. Order Switch Blocks only when adding or replacing them. Order Switch Blocks only when adding or replacing them.
A22NE-P A22NE-PD Specifications Certified Standard Ratings Certified Standards • UL508 (File No. E76675), CSA C22.2 No.14 6 A at 240 VAC, 10 A at 120 VAC • TÜV (EN60947-5-1) - Certified direct opening (EN60947-5-5) AC-15 3 A at 240 VAC DC-13 4 A at 24 VDC • CCC (GB14048.5) AC-15 3 A at 240 VAC DC-13 4 A at 24 VDC Certification body Standards File No. UL * UL508, C22.2 No.14 E76675 TÜV SÜD EN60947-5-1 Consult your OMRON (Certified direct opening), representative for details.
A22NE-P A22NE-PD Characteristics Operation Turn-reset Item Allowable operating Mechanical frequency Electrical Pull-reset Non-lighted model Lighted Model A22NE-@-P@@@-N A22NE-M-P@@@-@ Non-lighted model A22NE-MP-P@@@-N A22NE-MP-P@@@-N-69K 30 operations/minute or less (One operation consists of set and reset operations.) 30 operations/minute or less (One operation consists of set and reset operations.) Insulation resistance *1 100 MΩ min. (at 500 VDC) Contact resistance 100 mΩ max.
A22NE-P A22NE-PD Terminal connection Type Terminal Connection (BOTTOM VIEW) 1NC, 1NO (two contacts) 2NC (two contacts) 2NC, 1NO (three contacts) 3NC (three contacts) NC NO NC NC NC NC NO NC NC NC 1 3 1 1 1 1 3 1 1 1 2 4 2 2 2 2 4 2 2 2 Non-lighted A22NE-P X1 1 Lighted X1 1 3 X X 4 X2 2 1 X2 2 2 Note: The above terminal connection diagrams are examples for 1NO, 1NC (two contacts), or 2NC (two contacts).
A22NE-P (Unit: mm) Non-lighted Models A22NE-MP-P@@2-N A22NE-MP-P@@2-N-69K Pull-reset (40-dia.) Degree of Protection: IP65 oil-resistant models Pull-reset (40-dia.) Degree of Protection: IP69K 40 dia. 42.5 40 dia. 42.5 5.9 1.8 (0.5) 1.8 5.9 39 32 A22NE-P 32 39.5 A22NE-S-P@@2-N A22NE-M-P@@2-N Small Turn-reset (30-dia.) Degree of Protection: IP65 oil-resistant models Medium Turn-reset (40-dia.) Degree of Protection: IP65 oil-resistant models 30 dia. 40 dia. 42.5 42.5 1.8 1.8 (0.
A22NE-P A22NE-PD Accessories (Order Separately) Switch Block with Push-In Plus technology Switch Block (one contact) Switch Block (two contacts) A22NZ-S-P1@N A22NZ-S-P2@N 4 4 5 5 23.8 16.4 39.3 31.9 9.9 47.6 A22NE-P 9.9 47.6 Lighting unit Mounting Latches A22NZ-T-@PN A22NZ-H-02 R29.5 12 dia. 30 26.4 23.8 16.4 9.9 47.6 17.1 A22E 51.3 LED Lamp A22NZ-L-@@ 24.3 9.8 dia. 9 dia. Common Accessories and Tools Control Box A22NZ-A-B01Y Four, M4 Phillips binding screws 22.3 dia. 24.
A22NE-P Mounting to the Panel (1) Preparing the Panel (3) Mounting the Operation Unit on the Panel Panel hole dimension and panel thickness • If outer surface treatment such as coating is performed for the panel, the panel dimensions after outer surface treatment must meet the specified panel dimensions. Panel hole dimension Panel thickness 22.3 dia. 1 to 5 mm 22.3 +0.4 0 • Do not tighten the Tightening Nut more than necessary using tools such as pointed-nose pliers.
A22NE-P A22NE-PD Removing the Mounting Latch Attaching the LED Lamp to the Lighting Unit When the Mounting Latch is to be Removed When the LED Lamp is to be Installed • Press the lock lever in from the back side to release the lock, and then hook the Mounting Collar with a screwdriver, move it in the direction indicated at (2), and remove it. Turn the lever all of the way until it clicks into place.
A22NE-P Be sure to read the precautions for All PushButton Switches in the website at: http://www.ia.omron.com/. Indication and Meaning for Safe Use Warning Indicates a potentially hazardous situation that, if not avoided, could result in serious injury or death. Additionally there may be significant property damage. Comments on what to do or avoid doing, to use the product safely.
A22NE-P A22NE-PD • Do not insert more than one wire into each terminal insertion hole. • Do not mount A22N-P or A22NE-P Push-In Plus terminal switch blocks on A22N screw terminal blocks. Doing so may result in unsatisfactory performance. • When mounting on a device with high airtightness, test operation in advance. There is a risk that the negative pressure will prevent the Operation Unit of from returning.
A22NE-P 3. Recommended Ferrules and Crimp Tools Coating peeling amount Recommend Wire Type Stripping length (Ferrules not used) 0.25 to 1.5 mm2/AWG 24 to AWG 16 8 mm Recommended ferrules Applicable wire (2) (mm2) (1) Approx. 6˚ 0.25 24 (3) 0.34 22 Flat-blade screwdriver Approx. 6˚ The wiring and screwdriver angles for the Lighting Unit and Switch Block (2 contacts) are the same as for the Switch Block (1 contact) shown in the above illustration. 2.
A22NE-P A22NE-PD LED Lamps • A current-limiting resistor is built in the LED lamp, so the installation of an external resistance is not required. • Lighting malfunction of the LED lamp A micro-current of approximately 0.1 mA or less is sufficient to turn on the LED lamps. Take a countermeasure like adding a resistor to prevent mis-lighting in parallel to the LED lamp. The micro-current varies with the machine (leak current or stray capacity between cables, etc.).
Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) Screw Terminal Block types A22NE-PD A22E Install in 22-dia. or 25-dia. Panel Cutout A22NE-P (When Using a Ring) • Increase wiring efficiency with three-row mounting of Switch Units. (with non-lighted Switch Blocks, three Units can be mounted for multiple contacts). • Mounted using either open-type (fork-type) or closed-type (round-type) crimp terminals. • Oil-resistant to IP65 (non-lighted models) / IP65 (lighted models).
A22E A22NE-PD Ordering Information List of Models (Completely Assembled) Non-lighted Models (Without EMO/EMS Indication) Appearance Operation Degree of Protection Contact configuration *1 40-dia. head Medium Pull-reset A22E-MP A22NE-P 30-dia. head Small Turn-reset A22E-S IP65 oil-resistant models 40-dia. head Medium Turn-reset A22E-M 60-dia.
A22E Appearance Degree of Protection Operation Contact LED Lamp voltage configuration *1 6 VAC/VDC 12 VAC/VDC 1NC (1) 40-dia. head Push-lock Turn-reset Lighting unit (Direct lighting) A22E 1NC, 1NO (2) 40-dia.
A22E A22NE-PD Subassembled .... The Operation Unit, LED Lamp, Mounting Latches, and Switch Blocks can be ordered separately. Use them in combination for models that are not available as assembled Units. These can also be used as inventory for maintenance parts.
A22E Size Function Small (30 dia.) Sealing capability Medium (40 dia.) Large (60 dia.
A22E A22NE-PD Switch Non-lighted / Direct lighting Classification Non-lighted Direct lighting Appearance A22NE-P Contact specifications/ Configuration (Number of switch blocks) For Standard loads Model Model 1NC (1) A22-01M A22L-01M 1NC, 1NO (2) A22-11M A22L-11M 2NC (2) A22-02M A22L-02M Voltage-reduction lighting (100 VAC, 200 VAC) Classification 100 VAC, Lighted 200 VAC, Lighted Appearance A22E Contact specifications/ Configuration (Number of switch blocks) For Standard loads Model
A22E Item Appearance Contact specifications Microload A22-10S Standard load A22-01 Microload A22-01S Standard load A22-20 Microload A22-20S Standard load A22-02 Microload A22-02S Standard load A22-11 Microload A22-11S 1NC (Red) 2NO (Black) Switch Blocks (two contacts) 2NC (Red) 1NC + 1NO Contact (Black/ Red) Provided as standard. Order Switch Blocks only when adding or replacing them. Order Switch Blocks only when adding or replacing them.
A22E A22NE-PD Specifications Certified Standard Ratings Certified Standards • UL, cUL (File No. E41515) 6 A at 220 VAC, 10 A at 110 VAC • TÜV (EN60947-5-1) (Low Voltage Directive) 3 A at 220 VAC • CCC (GB14048.5) 3 A at 240 VAC, 1.5 A at 24 VDC Certification body Standards File No. UL *1 UL508, C22.2 No.14 E41515 TÜV SÜD CQC (CCC) GB14048.5 KOSHA *2 EN60947-5-1 A22NE-P LED Lamp Contacts (Standard Load) Rated current (A) 10 2003010303070635 Consult your OMRON representative for details.
A22E A22NE-PD Operating Characteristics Item Turn-reset Pull-reset Total travel force (TTF) 44.1 N max. Return force (RF) 0.25 N·m max. * 58.8 N max. Total travel (TT) 10 ±1 mm 5.5 ±1 mm 58.8 N max. * Rotation torque value. Terminal Arrangement (BOTTOM VIEW) Non-lighted (two contacts) Non-lighted (three contacts) Switch Blocks 10 16.7 Switch Blocks A22NE-P LOC OPE N 16.7 M3.5 screws Lighted (two contacts) 10 20.
A22E A22NE-PD Structure and Nomenclature Operation Unit Color: Red Non-lighted LED lighting Lamp Light source • LED Lamp A22NE-P Switch } Mounting Latches Switch Blocks Lighting unit Contact Ratings 10 A at 100 VAC (resistive load) 10 A at 24 VDC (resistive load) Lighting Method Non-lighted Lighted (Direct lighting) Lighted (Voltage-reduction lighting) A22E Lock Plate (Attached with the Operation Unit) (Refer to the "Mounting the Lock Plate" on page 50 for use.
A22E Switch dimensions when mounted to a 2NO (2NC) one-piece switch block A22EL-M Medium Turn-reset (40-dia.) Degree of Protection: IP65 oil-resistant models A22NE-PD Lighted Model 2 1.5 2 24 44 34 40 dia. 57.8 1.8 18.5 (0.5) 32 A22NE-P 6.5 72.7 5.9 41.2 Note: The operation unit is an example for the A22E-M. 54.7 Note: Unless otherwise specified, a tolerance of ±0.8 mm applies to all dimensions. Accessories (Order Separately) LED Lamp A22-6@, 12@, 24@ 9.5 dia. 10.6 dia. 20±1.
A22E A22NE-PD Installation Mounting to the Panel (1) Preparing the Panel (2) Mounting the Operation Unit on the Panel • The panel dimensions are shown below. • The panel thickness must be 1 to 5 mm. 3.2+0.2 0 • Insert the Operation Unit from the front surface of the panel, insert the Lock Ring and the Tightening Nut from the terminal side, then tighten the Ring. Before tightening, check that the rubber washer is present between the Operation Unit and the panel.
A22E A22NE-PD Installing/Replacing the LED Lamp Installing/Replacing on the Switch • Grip the lamp with your fingers, then rotate the lamp while pressing it against the Switch. A22NE-P Control Box (Enclosure) (1) Mounting the Switch (2) Creating a Cable Port Hole The Standard-size Legend Plate Frame can be mounted. Mount the Frame as shown in the following diagram. Mount the Switch in the same way as for an ordinary panel.
A22E A22NE-PD Safety Precautions Be sure to read the precautions for All PushButton Switches in the website at:http://www.ia.omron.com/. Indication and Meaning for Safe Use LED Lamps Warning Indicates a potentially hazardous situation that, if not avoided, could result in serious injury or death. Additionally there may be significant property damage. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage.
A22NE-PD/A22NE-P/A22E Ordering Information Common to Push-in Plus Terminal Block types (A22NE-PD/A22NE-P)/Screw Terminal Block types (A22E) Item Model A22Z-3466-1 Used in combination with the rubber packing when the level of protection is to be met between panels. *1 90-dia. black letters on yellow back-ground A22Z-3476-1 Cannot be used in combination with the Control Boxes. Used in combination with the rubber packing when the level of protection is to be met between panels. *1 60-dia.
A22NE-PD/A22NE-P/A22E A22NE-PD Dimensions (Unit: mm) Screw Terminal Block Type/Push-in Plus Terminal Block Type Hole Plug Round A22Z-3530 30-dia. Resin Attachment A22Z-A30 6 34.7 dia. 2.8 30 dia. 6.1 3.8 20.5 1 13 22.2 dia. 2.5 A22NE-P Legend Plates for Emergency Stop A22Z-3476-1 (90 dia.) A22Z-3466-1 (60 dia.) 90 dia. 60 dia. 60 dia. Black letters Black letter Black letters Yellow Yellow Yellow 22.2 dia. 22.2 dia. t1 t1 Lock Ring A22Z-3360 25-dia. Ring A22Z-R25 2 1 20.
A22NE-PD/A22NE-P/A22E A22NE-PD Common E-stop Shrouds A22Z-EG1, A22Z-EG1-W, A22Z-EG10, A22Z-EG10-W Screw Terminal Block type Mounting a 1-pole Switch Unit 52.2 max. 38 75 63 22.2 dia 75 min. (Determined by the height of the Switch surface in the lock position.) 2.8 5R 78 dia. 20.5 30 40 90 dia. A22E-M Switch Unit Panel 2.5+0.5 -1.5 Note: 1. The dimensions of the Shroud conform to the specifications of the SEMATECH Application Guide for SEMI S2-93. 2.
A22NE-PD/A22NE-P/A22E A22NE-PD E-stop Shrouds A22Z-EG2, A22Z-EG21, A22Z-EG22 105 dia. 98 dia. 3 35 12 79 dia. 2.8 20.6 M90 Detents inside (One on each side) A22NE-P 22.2 dia.
A22NE-PD/A22NE-P/A22E Screw Terminal Block Type Mounting a 1-pole Switch Unit 78 min. (Determined by the height of the Switch surface in the lock position.) 90 dia. C Screw Terminal Block Type Mounting a 2-pole Switch Unit 71.2 max. 52.2 max. 38 38 A22NE-PD E-stop Shroud A22Z-EG3 2.8 a. 20.5 1-pole Switch Unit 33 di 22.2 dia. Switch Mounting +0.5 2.5 -1.5 Dimension Panel Switch Mounting 2.5 +0.5 -1.5 Dimension C-C Push-in Plus Terminal Block Type Mounting a 1-pole Switch Unit 38.
A22E/A22NE-P A22NE-PD Safety Precautions Be sure to read the precautions for All PushButton Switches in the website at:http://www.ia.omron.com/. Indication and Meaning for Safe Use Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Mounting A22NE-P • Always make sure that the power is turned OFF before wiring the Switch. Also, do not touch the terminals or other current-carrying ports while power is being supplied.
Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron).
OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON SCIENTIFIC TECHNOLOGIES INC. 6550 Dumbarton Circle Fremont CA 94555 U.S.A. Tel: (1) 510-608-3400/Fax: (1) 510-744-1442 OMRON ASIA PACIFIC PTE. LTD. No.