Datasheet

A22NE-PD
10
A22NE-PD A22NE-P A22E Common Note
Common Accessories and Tools
Specifications
Certified Standard Ratings
UL508 (File No. E76675), CSA C22.2 No.14
5 A at 125 VAC, 3 A at 250 VAC B300
•TÜV (EN60947-5-1) - Certified direct opening -
(EN60947-5-5)
AC-15 3 A at 125 VAC
DC-13 1 A at 30 VDC
CCC (GB14048.5)
AC-15 3 A at 125 VAC
DC-13 1 A at 30 VDC
Applicable Standards
UL1059, UL486E
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a
short-circuit protection device. This fuse is not provided in the
main unit.
Certified Standards
Note: Only models with NC contacts have a direct opening
mechanism.
* UL-certification for CSA C22.2 No. 14 has been obtained.
Ratings
Contacts (Standard Load)
Note: 1. The above ratings were obtained by conducting tests under
the following conditions.
(1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 20 operations/minute
2. Minimum applicable load: 1 mA at 5 VDC (Resistive load)
The operating range may vary depending on the usage
conditions and type of load.
LED Lamp (A22NZ-L-RC)
Certification
body
Standards File No.
UL *
UL508, C22.2 No.14
E76675
V SÜD
EN60947-5-1
(Certified direct opening),
EN60947-5-5
Consult your OMRON
representative for details.
CQC (CCC) GB14048.5
Consult your OMRON
representative for details.
Rated
insulation
voltage (V)
Rated carry
current (A)
Rated
voltage
(V)
Rated current (A)
AC15
(Inductive
load)
AC12
(Resistive
load)
DC13
(Inductive
load)
DC12
(Resistive
load)
250 5
30 VAC --- --- --- ---
125 VAC 3 A 5 A --- ---
250 VAC 1.5 A 3 A --- ---
30 VDC --- --- 1 A 2 A
125 VDC --- --- 0.22 A 0.4 A
250 VDC --- --- 0.1 A 0.2 A
Rated voltage Operating voltage Current value
24 VAC/VDC 24 VAC/VDC ± 10% Approx. 12 mA