Datasheet
A22NE-PD
11
A22NE-PD A22NE-P A22E Common Note
Common Accessories and Tools
Characteristics
*1.
State when an LED is not added between terminals of the same polarity on a lighting unit.
*2. With no icing or condensation.
*3. The degree of protection from the front of the panel.
Operating Characteristics
* Rotation torque value.
Operation Turn-reset Pull-reset
Non-lighted model Lighted Model Non-lighted model
Non-lighted model
(Models with IP69K)
Item A22NE-@-PD@@-N-@ A22NE-M-PD@@-C-@ A22NE-MP-PD@@-N-@
A22NE-MP-PD
@@
-N-69K
Allowable operating
frequency
Mechanical
30 operations/minute or less (One operation consists of set and reset operations.)
Electrical 30 operations/minute or less (One operation consists of set and reset operations.)
Insulation resistance
*
1
100 MΩ min. (at 500 VDC)
Contact resistance 100 mΩ max. (initial value)
Dielectric
strength
Between
terminals of
same polarity*1
2,000 VAC, 50/60 Hz 1 minute (initial value)
Between
terminals of
different polarity
2,000 VAC, 50/60 Hz 1 minute (initial value)
Between each
terminal and
ground
2,000 VAC, 50/60 Hz 1 minute (initial value)
Vibration
resistance
Malfunction
10 to 55 Hz, 1.5 mm double amplitude (contact separation within 1 ms)
Shock
resistance
Malfunction
250 m/s
2
max. (contact separation within 1 ms)
Durability
Mechanical
300,000 operations min. (One operation consists of set and reset operations.)
100,000 operations min.
(One operation consists of
set and reset operations.)
Electrical
(100 mA at 24
VAC (Resistive
load))
250,000 operations min. (One operation consists of set and reset operations.)
100,000 operations min.
(One operation consists of
set and reset operations.)
Electrical
(3 mA at 250
VAC (Resistive
load))
100,000 operations min. (One operation consists of set and reset operations.)
Ambient operating temperature
*
2
-20 to +70°C -20 to +55°C -20 to +70°C
Ambient operating humidity 35 to 85% RH
Ambient storage temperature
*
2
-40 to +70°C
Degree of protection*3 IP65 oil-resistant models IP65 IP65 oil-resistant models IP69K
Electric shock protection class
Class II
PTI (tracking characteristic) 175
Degree of contamination 3 (EN 60947-5-1)
Minimum direct opening stroke 11 mm
Minimum direct opening force
45 N
Conditional short-circuit current
100 A (EN 60947-5-1)
Wight (for a 40-dia. head
2NC/2NO Operation Unit)
Approx. 95 g Approx. 95 g Approx. 125 g Approx. 135 g
Item
Turn-reset Pull-reset
Lighted / non-lighted models Non-lighted model
Non-lighted model
(Models with IP69K)
Total travel force (TTF) 45 N max. 60 N max. 70 N max.
Return force (RF) 0.25N·m max. * 60 N max. 70 N max.
Total travel (TT) 10 ±1 mm 5.5 ±1 mm