Datasheet
CP1E-E@@(S)D@-@ CP1E-N@@(S@)D@-@/NA20D@-@
30
Specifications of Expansion I/O Units and Expansion Units
Expandable CPU Units
• Expansion I/O Units and Expansion Units cannot be connected to E10/14/20(S) or N14/20 CPU Units.
• A total of up to three Expansion I/O Units and Expansion Units can be connected to an E30/40/60(S), N30/40/60(S@), NA20 CPU Unit.
●CP1E E10/14/20(S) or N14/20CPU Unit
●CP1E E30/40(S), N30/40/60(S@) or NA20 CPU Unit
Connection Methods
Connection cables for the Expansion I/O Units and Expansion Units are used to connect the Units. The length can be extended by using a CP1W-
CN811 I/O Connection Cable (length: 800 m).
Maximum Number of I/O Points for an Expanded System
Restrictions on External Power Supply Capacity
The following restrictions apply when using the CPU Unit’s external power supply.
●AC-power-supply E30/40(S), N30/40/60(S@) or NA20 CPU Unit
The power supply capacity is restricted for AC-power-supplyE30/40/60(S), N30/40/60(S@), NA20 CPU Units. It may not be possible to use the full
300 mA of the external power supply, though a CPU Unit can connect any CP-series Expansion I/O Unit or Expansion Unit.
The entire 300 mA from the external power supply can be used if Expansion Units and Expansion I/O Units are not connected.
Refer to the CP1E CPU Unit Hardware Manual (Cat. No. W479) for details.
●AC-power-supply or DC-power-supply E10/14/20(S), N14/20(S) CPU Unit
There is no external power supply on AC-power-supply or DC-power-supply E10/14/20, N14/20 CPU Units.
CPU Unit
Built-in I/O on CPU Unit Built-in Analog
Total number of
Expansion I/O Units and
Expansion Units that
can be connected
Number of inputs: 24
Number of outputs: 16
Total number of I/O points when three CP1W-40ED
@
Expansion I/O Units are connected
Total
Number of
inputs
Number of
outputs
AD DA Total
Number of
inputs
Number of
outputs
CP1E-E10D@-@ 10 6 4
None None
Not possible.
10 6 4
CP1E-@14@D@-@ 14 8 6 14 8 6
CP1E-@20@D@-@ 20 12 8 20 12 8
CP1E-@30@D@-@ 30 18 12
3 Units maximum
150 90 60
CP1E-@40@D@-@ 40 24 16 160 96 64
CP1E-@60@D@-@ 60 36 24 180 108 72
CP1E-NA20D@-@ 20 12 8 2 1 140 84 56
CP-series Expansion Units and Expansion I/O
Units cannot be connected.
A total of up to three CP-series Expansion I/O Units
and Expansion Units can be connected.
CH
NC
NC
NC
NC
NC
NC
COM
COM COM COM COM COM COM03 06 01 03 06
00 02 04 06 08 10
00 01 02 04 05 07 00 02 04 05 07
00 02 04 06 08 10
01 03 05 07 09 11 01 03 05 07 09 11
IN
40EDR
OUT
CH CH
CH CH
EXP
CH
CH
CH
111009080706050403020100
111009080706050403020100
0706050403020100
0706050403020100
CH
NC
NC
NC
NC
NC
NC
COM
COM COM COM COM COM COM03 06 01 03 06
00 02 04 06 08 10
00 01 02 04 05 07 00 02 04 05 07
00 02 04 06 08 10
01 03 05 07 09 11 01 03 05 07 09 11
IN
40EDR
OUT
CH CH
CH CH
EXP
CH
CH
CH
111009080706050403020100
111009080706050403020100
0706050403020100
0706050403020100
CH
NC
NC
NC
NC
NC
NC
COM
COM COM COM COM COM COM03 06 01 03 06
00 02 04 06 08 10
00 01 02 04 05 07 00 02 04 05 07
00 02 04 06 08 10
01 03 05 07 09 11 01 03 05 07 09 11
IN
40EDR
OUT
CH CH
CH CH
EXP
CH
CH
CH
111009080706050403020100
111009080706050403020100
0706050403020100
0706050403020100