Datasheet
CP1E-E@@(S)D@-@ CP1E-N@@(S@)D@-@/NA20D@-@
39
CP1W-CIF41 Ethernet Option Board version 2.0 or higher
●Specifications ●FINS Communications Service Specifications
Connecting to Support Software
Operating Environment and System Configuration
The following system is required to operate the CX-Programmer. Make sure your system provides the following conditions and has the necessary
components.
Connecting Methods
Using commercially available USB cable, connect the CX-Programmer to the peripheral USB port on the CPU Unit.
Host link connection can be made with RS-232C port to connect the Programming Device (CX-Programmer).
IP ADDRESS:
SUBNET MASK:
COMM ERR
10BASE-T
100BASE-TX
Front Rear
Label
Attach the label here to show
IP address and subnet mask.
Ethernet Connector
Used to connect the Ethernet
twisted-pair cable.
LED Indicators
Display the operating status of
the Option Board.
CPU Unit connector
Type 100/10Base-TX (Auto-MDIX)
Support Software CX-Programmer version 9.12 or higher
Transfer
Media access method
CSMA/CD
Modulation method Baseband
Transmission paths
Star form
Baud rate
100 Mbit/s
(100Base-TX)
10 Mbit/s
(10Base-TX)
• Half/full auto-negotiation for each port
• Link speed auto-sensing for each port
Transmission
media
• Unshielded
twisted-pair
(UDP) cable
Categories: 5, 5e
• Shielded twisted-
pair (STP) cable
Categories:
100Ω at 5, 5e
• Unshielded
twisted-pair
(UDP) cable
Categories: 3, 4, 5, 5e
•
Shielded twisted-
pair (STP) cable
Categories:
100
Ω
at 3, 4, 5, 5e
Transmission Distance
100 m (distance between hub and node)
Number of cascade
connections
No restrictions if switching hubs are used.
Number of nodes 254
Message Length 552 bytes max.
Date Length
540 bytes max.
(except for FINS header 10 byte and Command
header 2 byte.)
Number of buffer 8k byte
Protocol name FINS/UDP method FINS/TCP method
Protocol used
UDP/IP TCP/IP
The selection of UDP/IP or TCP/IP is
made from the FINS/TCP Tab by the Web
browser function.
Server/Client Only server (Cannot be used as a client)
Number of connections --- 2
Port number
9600 (default)
Can be changed.
9600 (default)
Can be changed.
Protection No
Yes (Specification
of client IP
addresses when
unit is used as a
server)
Item Description
Supported computer IBM PC/AT or equivalent
CD-ROM or DVD-ROM drive One or more
Supported Operating Systems
Windows 2000 (Service Pack 4 or higher), XP, Vista, or 7
(except 64-bit edition)
CPU Pentium II 333 MHz or faster
RAM 256 MB min. 512 MB or more recommended
Available hard disk space 600 MB min.
Display 800 x 600 SVGA min.
PLC and connection port USB port, RS-232C port, RS-422A/485 port or Ethernet port
USB port
A connector
Commercially available
USB cable
Peripheral USB port
(Conforming to USB 2.0, B connector)
B connector
CP1E CPU Unit
CX-Programmer