Datasheet

3
D4B-@N
Specifications
Standards and EC Directives
Conforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN50041
• EN60204-1
• EN ISO 14119
Certified Standards
Snap-action Models
* Adjustable roller lever, adjustable rod lever only.
Slow-action Models
* Adjustable roller lever, adjustable rod lever only.
Certified Standard Ratings
TÜV (EN60947-5-1), CCC (GB14048.5)
Note: As protection against short-circuiting, use either a gI-type or gG-type 10 A fuse that conforms to IEC60269.
UL/CSA: (UL508, CSA C22.2 No. 14)
A600
Certification body Standard File No.
TÜV Rheinland
EN60947-5-1
(certified direct
opening mechanism)
GS-ET-15
Consult your
OMRON
representative for
details.
EN60947-5-1
(uncertified direct
opening mechanism)
J50005477 *
UL UL508 E76675
CSA C22.2 No. 14 LR45746
CQC (CCC) GB14048.5
2003010305077612
2003010305095927
Certification body Standard File No.
TÜV Rheinland
EN60947-5-1
(certified direct
opening mechanism)
GS-ET-15
Consult your
OMRON
representative for
details.
EN60947-5-1
(uncertified direct
opening mechanism)
J50005477 *
UL UL508 E76675
CSA C22.2 No. 14 LR45746
CQC (CCC) GB14048.5
2003010305077612
2003010305095927
Item Utilization category AC-15
Rated operating current (Ie) 2 A
Rated operating voltage (Ue) 400 V
Rated voltage Carry current
Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC
240 VAC
480 VAC
600 VAC
10 A
60
30
15
12
6
3
1.5
1.2
7,200 720