Datasheet

17D4C
Do not expose the Switch to water exceeding 70°C or use it in steam.
When the D4C is used in a circuit of a device to be exported to
Europe, classified as Overvoltage Class III as specified in IEC664,
provide a contact protection circuit.
Tighten each screw to a torque according to the following table.
By removing the two screws from the head, the head direction can be
rotated 180×. After changing the head direction, re-tighten to the
torque specified above. Be careful not to allow any foreign substance
to enter the Switch.
Micro-load Models (D4C-6)
Switching Range
Micro-load models can be used for switching in the range shown
below.
No. Type Torque
1 M5 Allen-head bolt 4.90 to 5.88 N·m
2 M3.5 head mounting screw 0.78 to 0.88 N·m
3 M5 Allen-head bolt 4.90 to 5.88 N·m
30
24
12
5
0
1 10 100 1,0000.1
1mA
26mA0.16mA
800mW5mW
100mA 160mA