Datasheet

5D4C
Operating characteristics
Output circuit diagrams
Nomenclature
@-@01 @-@02 @-@03 @-@41 @-@42 @-@43 @-@31 @-@32 @-@33 @-@20 @-@50
Operating force (OF) 11.77 N max 17.65 N max5.69N
max
1.47 N
max
Release force (RF) 4.41 N min 1.47 N
max
-
Pre-travel (PT) 1.8 mm max 25° 15°
Over travel (OT) 3 mm min 40° -
Movement
differential (MD)
0.2 mm max -
Operating position
(OP)
15.7
±1 mm
28.5±1 mm 31.2
±1 mm
36.8±1 mm 24.9
±1 mm
34.3±1 mm - -
NC
COM
NO
E
NOCOM NC E
(2) (3)(1) (4)
NOCOM NC E
(2) (3)(1) (4)Pin No. Pin No.
Without indicator
Connector pin arrangement
With indicator
Note: Connection of LED indicator circuit to NO or
NC depends on selected model:
- LED turns OFF when operated (standard)
- LED turns ON when operated (-B models)
(Black)
(White)
(Red)
(Yellow/green)
(Black)
(White)
(Red)
(Yellow/green)
s
Protective nitrile
rubber cap (NBR)
LED indicator
Roller
Center lever
Built-in switch
Ground terminal
Molded resin
O ring
(NBR)
Nitrile rubber
diaphragm
Open space (to reduce
a change in internal
pneumatic pressure
and to prevent the
respiratory movement
of the Switch.)
Connector
receptacle
O ring
(NBR)
Spacer
(prevents the Switch
from biting cut chips.)
O ring
(NBR)
O ring
(NBR)
Roller
Lever
Diaphragm (NBR)
Protective cap (NBR)
Ground terminal
Molded resin
Built-in switch
Cable
(Example: D4C-1220) (Example: D4CC-4060)