Datasheet

2
D4E-@N
Ordering Information
Note: 1. When ordering, specify the current type by replacing the blank box of the model number with 0 for AC connector or 1 for DC connector.
2. For the plunger and lever actuator models, the NC and NO terminal indicators are reversed.
3. Models are also available with molded terminals and with molded terminals and operation indicators. Refer to page 8.
Plug
Select one of the specified Connector Plugs from the following table.
Specifications
Approved Standards
Ratings
Type One-touch connector type Screw terminal type
General-purpose
Micro load
General-purpose
without cable
Micro load
without cable
General-purpose
with cable
Micro load with
cable
Actuator Model Model Model Model Model Model
Roller plunger
D4E-1A@0N D4E-2A10N D4E-1A20N D4E-2A20N D4E-1A21N D4E-2A21N
Crossroller
plunger
D4E-1B@0N D4E-2B10N D4E-1B20N D4E-2B20N D4E-1B21N D4E-2B21N
Plunger
D4E-1C@0N D4E-2C@0N D4E-1C20N D4E-2C20N D4E-1C21N D4E-2C21N
Sealed roller
plunger
D4E-1D@0N D4E-2D10N D4E-1D20N D4E-2D20N D4E-1D21N D4E-2D21N
Sealed crossroller
plunger
D4E-1E@0N
---
D4E-1E20N D4E-2E20N D4E-1E21N D4E-2E21N
Sealed plunger
D4E-1F@0N D4E-2F10N D4E-1F20N D4E-2F20N D4E-1F21N D4E-2F21N
Roller lever
D4E-1G@0N D4E-2G10N D4E-1G20N D4E-2G20N D4E-1G21N D4E-2G21N
One-way action
roller lever
D4E-1H00N
---
D4E-1H20N D4E-2H20N D4E-1H21N
---
Applicable limit
switches
Current
Type
Type
No. of
conductors
Cable length Plug
D4E-@@00N AC
Straight
4
2 m
XS2F-A421-D90-F
5 m
XS2F-A421-G90-F
D4E-@@10N DC
2 m
XS2F-D421-D80-F
5 m
XS2F-D421-G80-F
Agency Standard File No. Approved models
UL UL508 E76675 D4E-@@20N Switches only except for Indicator-equipped Switches
CSA CSA C22.2 No. 14 LR45746 D4E-@@20N Switches only except for Indicator-equipped Switches
TÜV Rheinland EN60947-5-1 R9551015 Ask your OMRON representative for information on approved models.
CCC (CQC) GB14048.5 2003010305086795 Ask your OMRON representative for information on approved models.
Rated
voltage
Standard load Micro load
Non-inductive load (A) Inductive load (A)
Non-inductive load (A)
Resistive load Lamp load Inductive load Motor load Resistive load
NC NO NC NO NC NO NC NO NC NO
125 VAC
250 VAC
5 (1)
5 (1)
1.5 (1)
1.5 (1)
3 (1)
3 (1)
2 (1)
1
1 (1)
0.5
0.1
---
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
5 (1)
5 (1)
5 (1)
0.5
0.25
---
---
---
---
---
1.5 (1)
1.5 (1)
1.5 (1)
0.05
0.03
---
---
---
---
---
0.1
0.1
0.1
---
---
Minimum
applicable
load
Standard load Micro load
160 mA at 5
VDC
1 mA at 5 VDC
Inrush
current
NC 10 A max.
NO 10 A max.
Note: 1. The above current ratings are for a
standard current and the values in
parentheses are for models with a
connector.
2. Inductive loads have a power factor of 0.4
min. (AC) and a time constant of 7 ms
max. (DC).
3. Lamp load has an inrush current of 10
times the steady-state current.
4. Motor load has an inrush current of 6
times the steady-state current.