Datasheet
D4ER-@N
Preliminary Version
4
Specifications
Approved Standards
Ratings
Approved Standard Ratings
TÜV (EN60947-5-1)
Note:1. @:Actuator variation of item II
2. DC-12 1 A/30 VDC means as follows:
Applicable category: DC-12
Rated operating current (I
e): 1 A
Rated operating voltage (U
e): 30 VDC
Agency Standard File No. Approved models
TÜV Rheinland EN60947-5-1 R9551015, J9951016 Ask your OMRON representative for information on approved models.
Rated
voltage
Standard load Micro load
Non-inductive load (A) Inductive load (A)
Non-inductive load (A)
Resistive load Lamp load Inductive load Motor load Resistive load
NC NO NC NO NC NO NC NO NC NO
8 VDC
14 VDC
30 VDC
1
1
1
−
−
−
1
1
1
−
−
−
0.1
0.1
0.1
Minimum
applicable load
Standard load Micro load
160 mA at 5 VDC 1 mA at 5 VDC
Inrush
current
NC 10 A max.
NO 10 A max.
Note:1. The above current ratings are for a
standard current.
2. Inductive loads have a power factor of 0.4
min. (AC) and a time constant of 7 ms
max. (DC).
3. Lamp load has an inrush current of 10
times the steady-state current.
4. Motor load has an inrush current of 6
times the steady-state current.
Model
Applicable category
and ratings
Thermal current
(Ithe)
I II III
1
2
@
@
21/22
21/22
DC-12 1 A/30 VDC
DC-12 0.1 A/30 VDC
1A
0.1A
D4ER-1 G 21 N
I II III
Characteristics
Note:1. The following values are initial values.
2. The following ratings may vary depending on the model. Contact your OMRON representative for
further details.
* The IP67G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).
The IP67 indicates the same level of protection as defined by the IEC, and the G indicates that a device has
resistance to oil.
Degree of protection IP67 (IEC 60529) and IP67G (JIS C0920 Annex 1) *
Durability
Mechanical 4,000,000 operations min.
Electrical
500,000 operations min.
(1 A at 30VDC, resistive load)
4,000,000 operations min.
(10 mA at 24 VDC, resistive load)
Operating speed 0.1 mm/sec to 0.5 m/sec
Operating frequency
Mechanical: 120 operations/min
Electrical: 30 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance
15 mΩ max. (initial value for the built-in switch when
tested alone)
Dielectric
strength
Between terminals of
same polarity
1,000 VAC, 50/60 Hz for 1 min
Between each terminal and non-
current-carrying metal part
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV
(EN60947-5-1)
Rated insulation voltage (Ui) 250V
Pollution degree (operating environment) 3 (EN60947-5-1)
Short-circuit protective device (SCPD) 10 A fuse (type gG or gI, IEC60269 approved)
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe) 5 A (EN60947-5-1)
Protection against electric shock
Class II (grounding not required with double insulation)
Vibration
resistance
Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock
resistance
Destruction 1,000 m/s
2
max. (IEC68-2-27)
Malfunction 300 m/s
2
max. (IEC68-2-27)
Ambient operating temperature +5°C to +80°C (with no icing)
Ambient operating humidity 35% to 95%RH (with no condensation)
Weight
(in case of roller plunger)
Cable type (2m): Approx. 140 g
Pre-wired Connector type: Approx. 103 g