Wiring
Wiring Precautions
When connecting to the terminals via insulating tube and M3.5
crimp terminals, cross the crimp terminals as shown above so that
they do not rise up onto the case or the cover. Applicable lead wire
size: AWG20 to AWG18 (0.5 to 0.75mm
2
).
When connecting lead wires directly to terminals, perform wiring
securely so that there are no loose wire strands.
Do not push crimp terminals into gaps in the case interior. Doing so
may cause damage or deformation of the case.
Use lead wires of an appropriate length. Not doing so may cause
the cover to rise.
Use crimp terminals not more than 0.5 mm in thickness. Otherwise,
they will interfere with other components inside the case. The crimp
terminals shown below are not more than 0.5 mm thick.
Conduit Opening
Connect a recommended connector to the opening of the conduit
and tighten the connector to the proper torque. The case may be
damaged if an excessive tightening torque is applied.
In order to ensure IP67 degree of protection, wrap sealing tape
around the conduit end of the connector.
Be sure that the outer diameter of the cable connected to the con-
nector is correct.
Attach and tighten a conduit cap to the unused conduit opening
when wiring. The conduit cap is provided with the Switch.
Recommended Connectors
Use a connector with a screw section not exceeding 11 mm, other-
wise the screws will protrude into the case interior. The connectors
given in the following table have connectors with screw sections not
exceeding 11 mm.
Use the following connectors to ensure conformance to IP67.
Use LAPP connectors together with seal packing (JPK-16, GP-13.5,
or GPM20), and tighten with the applicable torque. Seal packing is
sold separately.
Maintenance and Repairs
The user must not perform repairs or maintenance. Contact the
machine manufacturer if repairs or maintenance are required.
Storage
Do not store the Switch in locations where harmful gases (e.g., H
2
S,
SO
2
, NH
3
, HNO
3
, or Cl
2
) or dust are present, or in locations subject to
high humidity levels.
Miscellaneous
Do not touch the solenoid. The temperature of the solenoid
increases when current is passed.
In conditions requiring greater rigidity, sealing performance, and oil
resistance, use OMRON’s D4BL.
Perform regular inspections.
Manufacturer Model
J.S.T. FV0.5-3.7
11
2221
3433
12
L
l F
B
D
dz
t: 0.5 mm
dz dia.: 3.7 mm
D dia.: 2.9 mm
B: 6.6 mm
L: 19 mm
F: 7.7 mm
I: 8.0 mm
Terminal screw
Crimp terminal
Size Manufacturer Model Applicable cable
diameter
G
1
/
2
LAPP ST-PF1/2
5380-1002
6.0 to 12.0 mm
Ohm Denki OA-W1609 7.0 to 9.0 mm
OA-W1611 9.0 to 11.0 mm
Pg13.5 LAPP S-13.5
5301-5030
5.0 to 12.0 mm
M20 LAPP ST-M20 *1.5
5311-1020
7.0 to 13.0 mm