Datasheet

7E2A
DC 3-wire Models / DC 4-wire (NO+NC)
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between 40°C and 25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.
3. For USA and Canada: use class 2 circuit only.
Size M18 M30
Type Shielded Non-shielded Shielded Non-shielded Non-shielded
Item
E2A-M18@S08-@@-B@
E2A-M18@S08-@@-C@
E2A-S18@S08-@@-B@
E2A-S18@S08-@@-C@
E2A-M18@N16-@@-B@
E2A-M18@N16-@@-C@
E2A-S18@N16-@@-B@
E2A-S18@N16-@@-C@
E2A-M30@S15-@@-B@
E2A-M30@S15-@@-C@
E2A-S30@S15-@@-B@
E2A-S30@S15-@@-C@
E2A-M30KN20-@@-B@
E2A-M30KN20-@@-C@
E2A-S30KN20-@@-B@
E2A-S30KN20-@@-C@
E2A-M30LN30-@@-B@
E2A-M30LN30-@@-C@
E2A-S30LN30-@@-B@
E2A-S30LN30-@@-C@
Sensing distance 8 mm10% 16 mm10% 15 mm10% 20 mm10% 30 mm10%
Setting distance 0 to 6.4 mm 0 to 12.8 mm 0 to 12 mm 0 to 16 mm 0 to 24 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target
(mild steel ST37)
24241 mm 48481 mm 45451 mm 60601 mm 90901 mm
Response frequency
(See note 1.)
500 Hz 400 Hz 250 Hz 100 Hz 100 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Current consumption
(DC 3-wire)
10 mA max.
Output type
-B models: PNP open collector
-C models: NPN open collector
Control
output
Load current
(See note 2.)
200 mA max. (32 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode
(with sensing object
approaching)
-B1/-C1 models: NO
-B2/-C2 models: NC
-B3/ -C3 models: NO+NC
For details, refer to the timing charts.
Protection circuit
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor,
Short-circuit protection
Ambient air temperature Operating: 40C to 70C, Storage: 40C to 85C (with no icing or condensation)
Temperature influence
(See note 2.)
10% max. of sensing distance at 23C within temperature range of 25C to 70C
15% max. of sensing distance at 23C within temperature range of
40C to 70C
Ambient humidity Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence 1% max. of sensing distance in rated voltage range 15%
Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
1,000 m/s
2
, 10 times each in X, Y and Z directions
Standard and listings (See
note 3.)
IP67 after IEC 60529
IP69k after DIN 40050
EMC after EN60947-5-2
Connection method
Pre-wired models (standard is dia 4mm PVC cable with length = 2m).
Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12 connectors.
Weight
(pak-
kaged)
Pre-wired model Approx. 160 g Approx. 280 g Approx. 280 g Approx. 370 g
Connector model Approx. 70 g Approx. 200 g Approx. 200 g Approx. 260 g
Material
Case Brass-nickel plated or stainless steel
Sensing surface PBT
Cable Standard cable is PVC dia 4mm. For other cable materials or diameters please refer to chapter 'Connectivity'
Clamping nut brass-nickel plated for brass models stainless steel for steel models