8 Inductive Sensors
DC 2-wire Models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between 40°C and 25°C and a power voltage between 30 and 32 VDC, use a load
current of 50 mA max.
3. For USA and Canada: use class 2 circuit only.
Size M8 M12
Type Shielded Non-shielded Shielded Non-shielded
Item
E2A-S08@S02-D@ E2A-S08@N04-D@
E2A-M12
@
S04-D
@
E2A-S12
@
S04-D
@
E2A-M12
@
N08-D
@
E2A-S12
@
N08-D
@
Sensing distance 2 mm 10% 4 mm 10% 4 mm 10% 8 mm 10%
Setting distance 0 to 1.6 mm 0 to 3.2 mm 0 to 3.2 mm 0 to 6.4 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target 881 mm 12121 mm 12121 mm 24241 mm
Response frequency (See note 1.) 1,500 Hz 1,000 Hz 1,000 Hz 800 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Leakage current 0.8 mA max.
Output type DC 2 wire type
Control
output
Load current
(See note 2.)
3 to 100 mA
Residual voltage 3 V max. (under load current of 100 mA with cable length of 2 m)
Indicator (see timing chart)
NO type: Operation indicator (Yellow), Setting indicator (Red)
NC type: Operation indicator (Yellow)
Operation mode
-D1 models: NO
-D2 models: NC
Protection circuit Surget suppressor, Short circuit protection
Ambient temperature Operating: 40C to 70C, Storage: 40C to 85C (with no icing or condensation)
Temperature influence
10% max. of sensing distance at 23C within temperature range of 25C to 70C
15% max. of sensing distance at 23C within temperature range of 40C to 70C
Ambient humidity Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence 1% max. of sensing distance in rated voltage range 15%
Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
500 m/s
2
, 10 times each in X, Y and Z directions 1,000 m/s
2
, 10 times each in X, Y and Z directions
Standard and listings (See note 3.)
IP67 after IEC 60529
IP69k after DIN 40050
EMC after EN60947-5-2
Connection method
Pre-wired models (standard is dia 4mm PVC cable with length = 2m).
Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12
connectors.
Weight
(packaged)
Pre-wired model Approx. 65 g Approx. 85 g
Connector model
M12 connector models: Approx. 20 g
M8 connector models: Approx. 15 g
Approx. 35 g
Material
Case Stainless steel Brass-nickel plated or stainless steel
Sensing surface PBT
Cable
Standard cable is PVC dia 4mm.
For other cable materials or diameters please refer to chapter 'Connectivity'
Clamping nut Brass-nickel plated
Brass-nickel plated for brass models stainless