Datasheet

9E2A
DC 2-wire Models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load
current of 50 mA max.
3. For USA and Canada: use class 2 circuit only.
Size M18 M30
Type Shielded Non-shielded Shielded Non-shielded
Item
E2A-M18@S08-D@
E2A-S18@S08-D@
E2A-M18@N16-D@
E2A-S18@N16-D@
E2A-M30
@
S15-D
@
E2A-S30
@
S15-D
@
E2A-M30
@
N30-D
@
E2A-M30
@
N20-D
@
E2A-S30
@
N30-D
@
E2A-S30
@
N20-D
@
Sensing distance 8 mm 10% 16 mm 10% 15 mm 10%
Short body: 20 m 10%
Long body: 30 m10%
Setting distance 0 to 6.4 mm 0 to 12.8 mm 0 to 12 mm
Short body: 0 to 16 mm
Long body: 0 to 24 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target 24x24x1 mm 48x48x1 mm 45x45x1 mm
Short body: 60x60x1 mm
Long body: 90x90x1mm
Response frequency (See note 1.) 500 Hz 400 Hz 250 Hz 100 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Leakage current 0.8 mA max.
Output type DC 2 wire type
Control
output
Load current
(See note 2.)
3 to 100 mA
Residual voltage 3 V max. (under load current of 100 mA with cable length of 2 m)
Indicator (see timing chart)
NO type: Operation indicator (Yellow), Setting indicator (Red)
NC type: Operation indicator (Yellow)
Operation mode
-D1 models: NO
-D2 models: NC
Protection circuit Surget suppressor, Short circuit protection
Ambient temperature Operating: 40C to 70C, Storage: 40C to 85C (with no icing or condensation)
Temperature influence
10% max. of sensing distance at 23C within temperature range of 25C to 70C
15% max. of sensing distance at 23C within temperature range of 40C to 70C
Ambient humidity Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence 1% max. of sensing distance in rated voltage range 15%
Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
500 m/s
2
, 10 times each in X, Y and Z directions
Standard and listings (See note 3.)
IP67 after IEC 60529
IP69k after DIN 40050
EMC after EN60947-5-2
Connection method
Pre-wired models (standard is dia 4mm PVC cable with length = 2m).
Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12
connectors.
Weight
(packaged)
Pre-wired model Approx. 160 g Approx. 280 g
short body: 280 g
long body: 370 g
Connector model Approx. 70 g Approx. 200 g
short body: 200 g
long body: 260 g
Material
Case Brass-nickel plated or stainless steel
Sensing surface PBT
Cable
Standard cable is PVC dia 4mm.
For other cable materials or diameters please refer to chapter 'Connectivity'
Clamping nut brass-nickel plated for brass models stainless steel for steel models