Datasheet

4
E2K-X
I/O Circuit Diagrams
DC 3-Wire Models (NPN)
DC 3-Wire Models (PNP)
AC 2-Wire Models
Leakage Current Residual Output Voltage
E2K-X@MY E2K-X@MY@ at 100 VAC E2K-X@MY@ at 200 VAC
0
1.0
1.5
2.0
300200100
V
mA
Power supply voltage (V)
(OFF)
Protective resistance
AC
power,
50/60Hz
Leakage current (mA)
40
60
80
100
120
0
20
5030201053
VL
100 VAC
V
A
ON
200100
OFF
Residual output voltage
Residual
Load Voltage
Load current
(
mA
)
Load voltage VL (V)
80
120
160
200
240
VL
200 VAC
V
A
ON
20
0
100503020
OFF
1053
0
40
Residual output voltage
Residual
Load
Voltage
Load current
(
mA
)
Load voltage VL (V)
Operation
mode
Model Timing chart Output circuit
NO
E2K-X4ME1
E2K-X8ME1
E2K-X15ME1
NC
E2K-X4ME2
E2K-X8ME2
E2K-X15ME2
Present
Not present
Operate
Reset
High
Low
ON
OFF
Load (between brown
and black leads)
Sensing object
Output voltage (between
black and blue leads)
Detection indicator (red)
10 kΩ
0 V
Tr
+V
Proximity
Sensor
main
circuit
Brown
Blue
Black
Load
*1. Load current: 200 mA max.
*2. When a transistor is connected.
*1
*2
Present
Not present
Operate
Reset
High
Low
ON
OFF
Load (between brown
and black leads)
Sensing object
Output voltage (between
black and blue leads)
Detection indicator (red)
Operation
mode
Model Timing chart Output circuit
NO
E2K-X4MF1
E2K-X8MF1
E2K-X15MF1
NC
E2K-X4MF2
E2K-X8MF2
E2K-X15MF2
Present
Not present
Operate
Reset
High
Low
ON
OFF
Load (between blue
and black leads)
Output voltage (between
black and brown leads)
Detection
indicator (red)
Sensing
object
Proximity
Sensor
main
circuit
Load
Brown
+V
0 V
Black
*1
2.2 Ω
47 kΩ
3.9 kΩ
*2
Blue
*1. Load current: 200 mA max.
*2. When a transistor is connected.
Present
Not present
Operate
Reset
High
Low
ON
OFF
Load (between blue
and black leads)
Output voltage (between
black and brown leads)
Detection
indicator (red)
Sensing
object
Operation
mode
Model Timing chart Output circuit
NO
E2K-X4MY1
E2K-X8MY1
E2K-X15MY1
NC
E2K-X4MY2
E2K-X8MY2
E2K-X15MY2
Present
Not present
Operate
Reset
ON
OFF
Load
Sensing object
Operation indicator (red)
Proximity
Sensor
main
circuit
Load
Brown
Blue
Present
Not present
Operate
Reset
ON
OFF
Load
Sensing object
Operation indicator (red)