Datasheet

6
E2K-X
Dimensions
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
44
20
60
80
17
10.7 dia.
21 dia.
*1
M12 × 1
Indicator *2
Two clamping nuts
Two washers
*1. E and F Models: 4-dia. vinyl-insulated round cable with 3
conductors (Conductor cross section: 0.2 mm
2
, Insulator
diameter: 1.2 mm), Standard length: 2 m
Y Models: 4-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.3 mm
2
, Insulator diameter: 1.3 mm),
Standard length: 2 m
*2. E and F Models: Detection indicator (red)
Y Models: Operation indicator (red)
E2K-X4ME
@
E2K-X4MF@
E2K-X4MY@
E2K-X8ME
@
E2K-X8MF@
E2K-X8MY@
44
20
60
80
24
16.6 dia.
29 dia.
M18 × 1
*1
Indicator *2
Two clamping nuts
Two washers
*1. E and F Models: 6-dia. vinyl-insulated round cable with 3
conductors (Conductor cross section: 0.5 mm
2
, Insulator
diameter: 1.9 mm), Standard length: 2 m
Y Models: 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm
2
, Insulator diameter: 1.9 mm),
Standard length: 2 m
*2. E and F Models: Detection indicator (red)
Y Models: Operation indicator (red)
5510
60
80
36
28.1 dia.
42 dia.
*1
M30 × 1.5
Indicator *2
Two clamping nuts
Two washers
*1. E and F Models: 6-dia. vinyl-insulated round cable with 3
conductors (Conductor cross section: 0.5 mm
2
, Insulator
diameter: 1.9 mm), Standard length: 2 m
Y Models: 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm
2
, Insulator diameter: 1.9 mm),
Standard length: 2 m
*2. E and F Models: Detection indicator (red)
Y Models: Operation indicator (red)
E2K-X15ME@
E2K-X15MF@
E2K-X15MY@
Mounting Hole Dimensions
Model F (mm)
E2K-X4M@@ 12.5 dia.
E2K-X8M@@ 18.5 dia.
E2K-X15M@@ 30.5 dia.
+0.5
0
+0.5
0
+0.5
0
F