Datasheet
E32
E32
53
En
g
ineerin
g
Data
J EXCESS GAIN RATIO
With standard sensing obj ect. With standard target at maximum sensitivity.
Standard
E32-TC200 with E3X-DAN
amplifier (Through-beam)
E32-DC200 with E3X-DAN
amplifier (Reflective)
E32-D21L with E3X-DAN
amplifier (Reflective)
Excess gain ratio
Long distance
High speed
Distance (m)
Long distance
Standard
High speed
Distance (mm)
Long distance
Standard
High speed
Distance (mm)
Excess gain ratio
Excess gain ratio
Oper-
ating
level
Oper-
ating
level
Oper-
ating
level
Through-beam Type, General Purpose
E32 - T1 1 with E3X- A11 amplifier
Sensing distance (mm)
Excess gain ratio
100
50
30
10
5
1
0 50 100 150 200 250 300
Operating l evel
350 400
100
10
1
0.1
100 200 3000
Excess gain ratio
E32 - T1 1 with E3JU - XR amplifier
Sensing distance (mm)