Datasheet

E3JK
14
I/O Circuit Diagrams
Relay Output Models
DC SSR Output Models
Note: Connect the brown cable to any polarity and the blue cable to the power supply because there is no polarity on the Emitter side.
*For the Through-beam Sensor, the Emitter is listed as E3JK-T@11-L, E3JK-T@12-L and the Receiver is listed as E3JK-T@11-D, E3JK-T@12-D in the table.
Confirm the models to order in “Ordering Information.”
Model
Timing chart
Output circuit
Light-ON Dark-ON
E3JK-TR11-L *
E3JK-TR12-L *
E3JK-TR13-L *
E3JK-TR14-L *
E3JK-TR11-D *
E3JK-TR12-D *
E3JK-TR13-D *
E3JK-TR14-D *
E3JK-RR11
E3JK-RR12
E3JK-RR13
E3JK-DR11
E3JK-DR12
E3JK-DR13
E3JK-DR14
Model
Timing chart
Output circuit
Light-ON Dark-ON
E3JK-TN11-L *
E3JK-TP11-L *
E3JK-TN12-L *
E3JK-TP12-L *
E3JK-TN13-L *
E3JK-TP13-L *
E3JK-TN14-L *
E3JK-TP14-L *
E3JK-TN11-D *
E3JK-TN12-D *
E3JK-TN13-D *
E3JK-TN14-D *
E3JK-RN11
E3JK-RN12
E3JK-RN13
E3JK-DN11
E3JK-DN12
E3JK-DN13
E3JK-DN14
E3JK-TP11-D *
E3JK-TP12-D *
E3JK-TP13-D *
E3JK-TP14-D *
E3JK-RP11
E3JK-RP12
E3JK-RP13
E3JK-DP11
E3JK-DP12
E3JK-DP13
E3JK-DP14
Photoelectric
Sensor
main
Circuit
Power
Source
24 to 240 VAC
24 to 240 VDC
Brown
Blue
Power
Indicator
(green)
Operation Indicator
(orange)
Relay
Output Tc-Tb
Output Tc-Ta
Incident light
No incident light
ON
OFF
Operate
Reset
Conducting
Not conducting
Conducting
Not conducting
Operation Indicator
(orange)
Relay
Output Tc-Tb
Output Tc-Ta
Incident light
No incident light
ON
OFF
Operate
Reset
Conducting
Not conducting
Conducting
Not conducting
Photoelectric
Sensor
main
Circuit
Stability
Indicator
(green)
Operation Indicator
(orange)
Power
Source
24 to 240 VAC
24 to 240 VDC
Brown
Blue
White
Black
Gray
Ta
Contact output (SPDT),
250 VAC, 3 A max.,
5 VDC, 10 mA min.
Tb
Tc
Photoelectric
Sensor
main
Circuit
10 to 30 VDC
0 V
Brown
Blue
Power
Indicator
(green)
Operation Indicator
(orange)
Output
transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation Indicator
(orange)
Output
transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Photoelectric
Sensor
main
Circuit
10 to 30 VDC
0 V
Brown
Black
Blue
100 mA max.
Load
Stability
Indicator
(green)
Operation Indicator
(orange)
Operation Indicator
(orange)
Output
transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation Indicator
(orange)
Output
transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Photoelectric
Sensor
main
Circuit
10 to 30 VDC
0 V
Brown
Black
Blue
100 mA max.
Load
Stability
Indicator
(green)
Operation Indicator
(orange)