New Product Digital Temperature Controller E5@C/E5@C-T Large White PV Display That's Easier to Read. Easy to Use, from Model Selection to Setup and Operation. New Plug-in Models That Are Convenient for Maintenance and Replacement as replacing temperature controllers is possible without changing wiring. New Models That Mount to DIN Track and Are Ideal for HMI/PLC Connections. And Programmable Models to Support a Wider Range of Applications.
Digital Temperature Controller E5GC (48 × 24 mm) Easy Operation and High Performance of the E5@C Series in a Compact 48 × 24mm Body • A compact body of 48 × 24 × 90 mm (W × H × D) that is ideal for small equipment, laboratory instruments, and others. • White PV display with a height of 10.5 mm for high visibility even with the compact body. • Removable terminal block to simplify maintenance. Select from screw terminals or screwless clamp terminals for the wiring method. • High-speed sampling at 50 ms.
E5GC Model Number Legend and Standard Models Model Number Legend E5GC-@@ @ @ @ M-@@@ (Example: E5GC-RX1A6M-015) −− − − − − −−− A B C D E F Model A B Control No.
E5GC Optional Products (Order Separately) USB-Serial Conversion Cable Model E58-CIFQ2 Model Y92S-P12 Communications Conversion Cable Model E58-CIFQ2-E Current Transformers (CTs) Model E54-CT1 E54-CT3 Mounting Adapter Model Y92F-53 (2pcs) Note: This Mounting Adapter is provided with the Digital Temperature Controller. 4 Note: This Waterproof Packing is provided with the Digital Temperature Controller. Draw-out Jig Note: Always use this product together with the E58-CIFQ2.
E5GC Specifications Ratings Power supply voltage Operating voltage range Power consumption Sensor input Input impedance Control method Relay output Control output Auxiliary output Voltage output (for driving SSR) Linear current output Number of outputs Output specifications Number of inputs Event input External contact input specifications Setting method Indication method Multi SP Bank switching Other functions Ambient operating temperature Ambient operating humidity Storage temperature Altitude R
E5GC Input Ranges ●Thermocouple/Platinum Resistance Thermometer (Universal inputs) Sensor type Platinum resistance thermometer Sensor specification Pt100 Infrared temperature sensor Thermocouple JPt100 K J T E L U N R S B W PLII 10 to 70°C 60 to 120°C 115 to 165°C 120 165 140 to 260°C 2300 2300 1800 1800 1700 1700 1700 Temperature range (°C) 1600 1500 1400 1300 1300 1300 1300 1200 1100 1000 900 850 850 850 800 700 600 600 500.0 500 500.0 500.0 400.
E5GC Alarm Types Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (See note.) Auxiliary outputs are allocated to alarms. ON delays and OFF delays (0 to 999 s) can also be specified. Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed. To use alarm 1, set the output assignment to alarm 1.
E5GC *1 With set values 1, 4, and 5, the upper- and lower-limit values can be set independently for each alarm type, and are expressed as “L” and “H.
E5GC Characteristics Indication accuracy (at the temperature of 23°C) Influence of temperature *2 Influence of voltage *2 Input sampling period Hysteresis Proportional band (P) Integral time (I) Derivative time (D) Proportional band (P) for cooling Integral time (I) for cooling Derivative time (D) for cooling Control period Manual reset value Alarm setting range Influence of signal source resistance Insulation resistance Thermocouple: (±0.
E5GC USB-Serial Conversion Cable Applicable OS Windows XP, Vista, or 7 Applicable software CX-Thermo version 4.62 or higher Applicable models E5@C-T Series, E5@C Series, and E5CB Series Component Communications When Digital Temperature Controllers are connected, set points and RUN/STOP commands can be sent from the Digital Temperature Controller that is set as the master to the Digital Temperature Controllers that are set as slaves. Slope and offsets can be set for the set point.
E5GC External Connections E5GC Control Outputs E5GC-@ @ @ @ @ M - @ @ @ Relay output 250 VAC, 2 A (resistive load) Voltage output (for driving SSR) 12 VDC, 21 mA Linear current output 0 to 20 mA DC 4 to 20 mA DC Load: 500 Ω max. (1) (2)(3)(4)(5) (6) ↑ Terminal type Auxiliary outputs 1, 2 The E5GC is set for a K-type thermocouple (input type = 5) by default. An input error (s.err) wil occur if the input type setting does not agree with the temperature sensor. Check the input type.
E5GC Wiring Methods E5GC-@C Controllers with Screwless Clamp Terminal Blocks E5GC-@6 Controllers with Screw Terminal Blocks (M3 Screws) Controllers with Screw Terminal Blocks Controllers with Screwless Clamp Terminals Blocks • Terminal type: Forked or round crimped terminals • Tightening torque for all terminals: 0.43 to 0.58 N·m • Wire stripping length: 8 to 12 mm • Ferrules: 8 to 12 mm 0.8 to 1.4 mm 5.8 mm max. 8 to 12 mm 8 to 12 mm 5.8 mm max.
E5GC Dimensions (Unit: mm) Controllers E5GC-@6 Controllers with Screw Terminal Blocks Waterproof Packing (Accessory) 63.6 48 Mounting Adapter (Accessory) Terminal Cover (Accessory) 4 90 44.8 1 22 40.8 24 22 • Use two Mounting Adapters, either on the top and bottom or on the right and left. • Setup Tool ports are provided as standard feature. Use these ports to connect a computer to the Digital Temperature Controller.
E5GC Accessories (Order Separately) ● USB-Serial Conversion Cable E58-CIFQ2 (2110) 250 263 1510 LED (RD) USB connector (type A plug) Serial connector LED (PWR) LED (SD) ● Conversion Cable E58-CIFQ2-E Conversion Cable Connecting to the E58-CIFQ2 USB-Serial Conversion Cable (2110) (1510) 250 263 1510 E58-CIFQ2 (Order separately) Note: Always use this product together with the E58-CIFQ2. Conversion Cable ● Current Transformers E54-CT1 21 15 Thru-current (Io) vs.
E5GC ● Mounting Adapter Y92F-53 (Two provided.) One pair is provided with the Termperature Controller. Order this Adapter separately if it becomes lost or damaged. 34.7 12 11.8 9.4 ● Waterproof Packing Y92S-P12 The Waterproof Packing is provided with the Temperature Controller. Order the Waterproof Packing separately if it becomes lost or damaged. The Waterproof Packing can be used to achieve an IP66 degree of protection.
Digital Temperature Controller E5CC/E5CC-U (48 × 48 mm) Large White PV Display That’s Easier to Read. Easy to Use, from Model Selection to Setup and Operation. A Complete Range of I/O Capacities, Functions, and Performance. Handles More Applications. • The white PV display with a height of 15.2 mm improves visibility. 48 × 48 mm 48 × 48 mm • High-speed sampling at 50 ms.
E5CC/E5CC-U Model Number Legend and Standard Models Model Number Legend ●Models with Screw Terminals E5CC-@@ 3 @ 5 M -@@@ (Example: E5CC-RX3A5M-000) −− − − − − −−− A B C D E F A Model Control outputs 1 and 2 B C D No.
E5CC/E5CC-U Model Number Legend ●Plug-in Models E5CC-@@ @ @ U M -000 (Example: E5CC-RW0AUM-000) A B C D E A Model B F C D Control No.
E5CC/E5CC-U Optional Products (Order Separately) USB-Serial Conversion Cable Front Covers Model E58-CIFQ2 Type Hard Front Cover Soft Front Cover Model Y92A-48H Y92A-48D Terminal Covers (for E5CC) CX-Thermo Support Software Model E53-COV17 E53-COV23 (3pcs) Model EST2-2C-MV4 Note: The Terminal Covers E53-COV23 are provided only with E5CC Controllers. The E53-COV10 cannot be used. Refer to page 28 for the mounted dimensions. Waterproof Packing Note: CX-Thermo version 4.
E5CC/E5CC-U Specifications Ratings Power supply voltage Operating voltage range Power consumption Sensor input Input impedance Control method Relay output Control output Voltage output (for driving SSR) Linear current output Number of outputs Auxiliary output Output specifications Number of inputs Event input* Transfer output* External contact input specifications Number of outputs Output specifications Setting method Remote SP input* Indication method Multi SP* Bank switching Other functions Amb
E5CC/E5CC-U Input Ranges ●Thermocouple/Platinum Resistance Thermometer (Universal inputs) Sensor type Platinum resistance thermometer Sensor specification Pt100 Infrared temperature sensor Thermocouple JPt100 K J T E L U N R S B W PLII 10 to 70°C 60 to 120°C 115 to 165°C 120 165 140 to 260°C 2300 2300 1800 1800 1700 1700 1700 Temperature range (°C) 1600 1500 1400 1300 1300 1300 1300 1200 1100 1000 900 850 850 850 800 700 600 600 500.0 500 500.0 500.0 400.
E5CC/E5CC-U Alarm Types Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit. (see note.) Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified. Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed. To use alarm 1, set the output assignment to alarm 1.
E5CC/E5CC-U *1 *2 With set values 1, 4 and 5, the upper and lower limit values can be set independently for each alarm type, and are expressed as “L” and “H.
E5CC/E5CC-U Characteristics E5CC Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max. Indication accuracy CT input: ±5% FS ±1 digit max. (at the ambient temperature of 23°C) E5CC-U Thermocouple: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.
E5CC/E5CC-U USB-Serial Conversion Cable Windows XP, Vista, or 7 Applicable software CX-Thermo version 4.5 or higher (Version 4.61 or higher is required for the E5CC-U.) Applicable models E5@C-T Series, E5@C Series, and E5CB Series USB interface standard Conforms to USB Specification 2.0. DTE speed 38400 bps Connector specifications Computer: USB (type A plug) Digital Temperature Controller: Special serial connector Power supply Bus power (Supplied from USB host controller.
E5CC/E5CC-U External Connections E5CC Control output 1 E5CC-@@ 3 @ 5 M - @ @ @ Relay output 250 VAC, 3A (resistive load) Voltage output (for driving SSR) 12 VDC, 21 mA Linear current output 0 to 20 mA DC 4 to 20 mA DC Load: 500 Ω max.
E5CC/E5CC-U Isolation/Insulation Block Diagrams • E5CC Models with 3 Auxiliary Outputs Sensor input, CT inputs, and remote SP input Communications and event inputs Voltage output (for driving SSR), linear current output, and transfer output Power supply Relay output Auxiliary outputs 1, 2, 3 : Reinforced insulation : Functional isolation Note: Auxiliary outputs 1 to 3 are not insulated.
E5CC/E5CC-U Dimensions (Unit: mm) Controllers E5CC 73.1 60 4 48 × 48 1 48 × 48 44.8 × 44.8 48.8 58 Waterproof Packing (Accessory) Mounting Adapter (Accessory) Terminal Cover (E53-COV17) (Sold separately) The Setup Tool port is on the top of the Temperature Controller. It is used to connect the Temperature Controller to the computer to use the Setup Tool. The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection.
E5CC/E5CC-U Accessories (Order Separately) ● USB-Serial Conversion Cable E58-CIFQ2 (2110) 250 263 1510 LED (RD) USB connector (type A plug) Serial connector LED (PWR) LED (SD) ● Terminal Covers E53-COV17 ● Terminal Covers E53-COV23 (Three Covers provided.) 48 2 3.8 48.8 10 Terminal Cover (E53-COV23) 22 44.8 9.1 ● Terminal Cover (for the P3GA-11 Back-connecting Socket) Y92A-48G Twelve, 6.4-dia. 34 Y92A-48G UP 47.7×47.7 48×48 P C 16.5 24.6 27.6 47.
E5CC/E5CC-U ● Current Transformers E54-CT1 21 15 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) E54-CT1 2.8 5.8 dia. 7.5 25 Maximum continuous heater current: 50 A (50/60 Hz) Number of windings: 400±2 Winding resistance: 18±2 Ω 3 Output voltage (Eo) V (r.m.s.) 10.5 40 Two, 3.5 dia. 10 30 100V Frequency: 50 Hz ∞ 1kΩ 10 Distortion factor 10% 1 3% 1% 100mV 100Ω 10 E54-CT3 2.36 dia. 30 RL=10Ω 1 12 dia. 9 100μV 10 1 40 × 40 10 100mA 1 10 100 1,000A Thru-current (Io) A (r.
E5CC/E5CC-U ● Adapter Y92F-45 Note: 1. Use this Adapter when the Front Panel has already been prepared for the E5B@. 2. Only black is available. 3. You cannot use the E58-CIFQ2 USB-Serial Conversion Cable if you use the Y92F-45 Adapter. To use the USB-Serial Conversion Cable to make the settings, do so before you mount the Temperature Controller in the panel. Fixture (Accessory) 76 4.7 69.6 to 77.
E5CC/E5CC-U ● Watertight Cover ● Mounting Adapter Y92A-48N Y92F-49 21.9 14 The Mounting Adapter is provided with the Temperature Controller. Order this Adapter separately if it becomes lost or damaged. (2) 87.7 69 79.2 12 67.6 ● Protective Cover ● Protective Cover Y92A-48D Y92A-48H Note: This Protective Cover cannot be used if the Waterproof Packing is installed. This Protective Cover is hard type. Please use it for the mis-operation prevention etc. This Protective Cover is soft type.
MEMO 33
Digital Temperature Controller E5EC/E5AC (48 × 96 mm/96 × 96 mm) Large White PV Display That’s Easier to Read. Easy to Use, from Model Selection to Setup and Operation. A Complete Range of I/O Capacities, Functions, and Performance. Handles More Applications. • A white LCD PV display with a height of approx. 18 mm for the E5EC and 25 mm for the E5AC improves visibility. • Tool ports are provided both on the top panel and the front panel.
E5EC/E5AC Model Number Legend and Standard Models Model Number Legend ●Models with Screw Terminals E5EC-@@ 4 @ 5 M -@@@ (Example: E5EC-RX4A5M-000) −− − − − − −−− A B C D E F E5AC-@@ 4 @ 5 M -@@@ (Example: E5AC-RX4A5M-000) −− − − − − −−− A B C D E F A Model B C D E F No.
E5EC/E5AC Optional Products (Order Separately) USB-Serial Conversion Cable Model E58-CIFQ2 Communications Conversion Cable Note: Always use this product together with the E58-CIFQ2. This Cable is used to connect to the front-panel Setup Tool port. Terminal Covers Model E53-COV24 (3pcs) Note: The Terminal Covers E53-COV24 are provided with the Digital Temperature Controller. Waterproof Packing Model Y92S-P9 Y92S-P10 Note: This Waterproof Packing is provided with the Digital Temperature Controller.
E5EC/E5AC Specifications Ratings Power supply voltage Operating voltage range E5EC Power consumption E5AC Sensor input Input impedance Control method Relay output Control output Auxiliary output Voltage output (for driving SSR) Linear current output Number of outputs Output specifications Number of inputs Event input External contact input specifications Transfer output Number of outputs Output specifications Remote SP input Potentiometer input Setting method Indication method Multi SP Bank switchi
E5EC/E5AC Input Ranges ●Thermocouple/Platinum Resistance Thermometer (Universal inputs) Sensor type Platinum resistance thermometer Sensor specification Pt100 Infrared temperature sensor Thermocouple JPt100 K J T E L U N R S B W PLII 10 to 70°C 60 to 120°C 115 to 165°C 120 165 140 to 260°C 2300 2300 1800 1800 1700 1700 1700 Temperature range (°C) 1600 1500 1400 1300 1300 1300 1300 1200 1100 1000 900 850 850 850 800 700 600 600 500.0 500 500.0 500.0 400.
E5EC/E5AC Alarm Types Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit. (see note.) Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified. Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed. To use alarm 1, set the output assignment to alarm 1.
E5EC/E5AC *1 With set values 1, 4 and 5, the upper and lower limit values can be set independently for each alarm type, and are expressed as “L” and “H.” *2. Set value: 1, Upper- and lower-limit alarm Case 2 Case 1 Case 3 (Always ON) H<0, L<0 L H SP H<0, L>0 |H| < |L| H SP L H H>0, L<0 |H| > |L| H SP L H<0, L>0 |H| ≥ |L| L SP SP H L H>0, L<0 |H| ≤ |L| *3.
E5EC/E5AC Characteristics Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max. CT input: ±5% FS ±1 digit max. Potentiometer input: ±5% FS ±1 digit max. Transfer output accuracy ±0.3% FS max. Remote SP Input Type ±0.2% FS ±1 digit max.
E5EC/E5AC USB-Serial Conversion Cable Windows XP, Vista, or 7 Applicable software CX-Thermo version 4.5 or higher Applicable models E5@C-T Series, E5@C Series, and E5CB Series USB interface standard Conforms to USB Specification 2.0. DTE speed 38,400 bps Connector specifications Computer: USB (type A plug) Digital Temperature Controller: Special serial connector Power supply Bus power (Supplied from USB host controller.)* Power supply voltage 5 VDC Current consumption 450 mA max.
E5EC/E5AC External Connections E5EC/E5AC E5EC-@@ 4 @ 5 M - @ @ @ (1) (2) (3) (4) (5) ↑ Terminal type Control output 1 Control output 2 Relay output 250 VAC, 5 A (resistive load) Voltage output (for driving SSR) 12 VDC, 40 mA When There Is a Control Output 2: 21 mA Linear current output 0 to 20 mA DC 4 to 20 mA DC Load: 500 Ω max. Relay output 250 VAC, 5 A (resistive load) Voltage output (for driving SSR) 12 VDC, 21 mA Linear current output 0 to 20 mA DC 4 to 20 mA DC Load: 500 Ω max.
E5EC/E5AC Nomenclature E5EC Front panel No. 1 display PV or specified parameter Temperature unit Top View of E5EC No. 2 display Operation indicators SP or specified parameter value No. 3 display Front-panel Setup Tool port Manipulated value or other value Manipulated or other value Use the Uvalue D Keys to set Top-panel Setup Tool port the parameter. Use S Key to change the digit (default setting). Use the M Key to change to another parameter. Press O Key once to go to Adjustment Level.
E5EC/E5AC Dimensions (Unit: mm) Controllers E5EC 48 (64) 60 4 1 96 44 The Setup Tool ports are on the front and top of the Digital Temperature Controller. It is used to connect the Temperature Controller to the computer to use the Setup Tool. The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection. 91 Refer to the instructions that are provided with the USB-Serial Conversion Cable for the connection procedure.
E5EC/E5AC E5AC (64) 60 4 1 96 x 96 91 x 91 110 Waterproof Packing (Accessory) 91 Mounting Adapter (Accessory) The Setup Tool ports are on the front and top of the Digital Temperature Controller. It is used to connect the Temperature Controller to the computer to use the Setup Tool. The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection. Refer to the instructions that are provided with the USB-Serial Conversion Cable for the connection procedure.
E5EC/E5AC Accessories (Order Separately) ● USB-Serial Conversion Cable E58-CIFQ2 (2110) 250 263 1510 LED (RD) USB connector (type A plug) Serial connector LED (PWR) LED (SD) ● Conversion Cable E58-CIFQ2-E Conversion Cable Connecting to the E58-CIFQ2 USB-Serial Conversion Cable (2110) (1510) 250 263 E58-CIFQ2 (Order Separately) 1510 Conversion Cable Note: Always use this product together with the E58-CIFQ2. ● Terminal Covers E53-COV24 (Three Covers provided.) 2 3.
E5EC/E5AC ● Watertight Cover Y92A-96N (96 × 96) ● Watertight Cover Y92A-49N (48 × 96) 21.9 21.9 (2) (2) 131.7 131.7 67.6 115.6 29.4 29.4 ● Current Transformers E54-CT1 21 15 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) E54-CT1 2.8 5.8 dia. 7.5 25 Maximum continuous heater current: 50 A (50/60 Hz) Number of windings: 400±2 Winding resistance: 18±2 Ω 3 Output voltage (Eo) V (r.m.s.) 10.5 40 Two, 3.5 dia.
MEMO 49
Digital Temperature Controller E5DC (22.5 mm Wide, and DIN Track-mounting Type) The E5DC Mounts to DIN Track and Is Ideal for Connections to HMIs and PLCs. It provides the Same Easy Operation and Advanced Performance as the Rest of the E5@C Series. • A slim body at 85 × 22.5 mm (D × W) that fits into narrow control panels and mounts to DIN Track. • Removable terminal block for easy replacement to simplify maintenance. • High-speed sampling at 50 ms for applications with high-speed temperature increases.
E5DC Model Number Legend and Standard Models Model Number Legend ●Models with Screw Terminals E5DC-@@ @ @ S M-@@@ (Example: E5DC-RX0ASM-015) −− − − − − −−− A B C D E F A Model B No. of Control auxiliary output 1 outputs C Power supply voltage D E F Terminal type Input type Options Meaning E5DC 22.
E5DC Optional Products (Order Separately) USB-Serial Conversion Cable End Plate Model E58-CIFQ2 Model PFP-M Communications Conversion Cable Spacer Model E58-CIFQ2-E Model PFP-S Note: Always use this product together with the E58-CIFQ2. This Cable is used to connect to the front-panel Setup Tool port. DIN Tracks Model PFP-100N PFP-50N Current Transformers (CTs) Hole diameter 5.8 mm 12.
E5DC Specifications Ratings Power supply voltage Operating voltage range Power consumption Sensor input Input impedance Control method Relay output Control output Auxiliary output Voltage output (for driving SSR) Linear current output Number of outputs Output specifications Number of inputs Event input External contact input specifications Setting method Indication method Multi SP Bank switching Other functions Ambient operating temperature Ambient operating humidity Storage temperature Altitude R
E5DC Input Ranges ●Thermocouple/Platinum Resistance Thermometer (Universal inputs) Sensor type Platinum resistance thermometer Sensor specification Pt100 Infrared temperature sensor Thermocouple JPt100 K J T E L U N R S B W PLII 10 to 70°C 60 to 120°C 115 to 165°C 120 165 140 to 260°C 2300 2300 1800 1800 1700 1700 1700 Temperature range (°C) 1600 1500 1400 1300 1300 1300 1300 1200 1100 1000 900 850 850 850 800 700 600 600 500.0 500 500.0 500.0 400.
E5DC Alarm Types Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (See note.) Auxiliary outputs are allocated to alarms. ON delays and OFF delays (0 to 999 s) can also be specified. Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed. To use alarm 1, set the output assignment to alarm 1.
E5DC *1 With set values 1, 4, and 5, the upper- and lower-limit values can be set independently for each alarm type, and are expressed as “L” and “H.
E5DC Characteristics Thermocouple: (±0.3 % of indication value or ±1°C, whichever is greater) ±1 digit max.*1 Indication accuracy Platinum resistance thermometer: (±0.2 % of indication value or ±0.8°C, whichever is greater) ±1 digit max. (when mounted individually, ambiAnalog input: ±0.2% FS ±1 digit max. ent temperature of 23°C) CT input: ±5% FS ±1 digit max. Influence of temperature *2 Thermocouple input (R, S, B, W, PL II): (±1% of indication value or ±10°C, whichever is greater) ±1 digit max.
E5DC USB-Serial Conversion Cable Windows XP, Vista, or 7 Applicable software CX-Thermo version 4.6 or higher Applicable models E5@C-T Series, E5@C Series, and E5CB Series USB interface standard Conforms to USB Specification 2.0 DTE speed 38,400 bps Connector specifications Computer: USB (Type A plug) Digital Temperature Controller: Special serial connector Power supply Bus power (Supplied from the USB host controller) * Power supply voltage 5 VDC Current consumption 450 mA max.
E5DC External Connections E5DC Control output Auxiliary outputs 1, 2 Relay output 250 VAC, 3 A (resistive load) Voltage output (for driving SSR) 12 VDC, 21 mA Linear current output 0 to 20 mA DC 4 to 20 mA DC Load: 500 Ω max. The E5DC is set for a K-type thermocouple (input type = 5) by default. An input error (s.err) will occur if the input type setting does not agree with the temperature sensor. Check the input type.
E5DC Nomenclature E5DC Front panel Bottom View of E5DC No. 1 display PV or specified parameter Operation indicators No.2 display SP or specified parameter value Press O Key once to go to Adjustment Level. Use the M Key to change to another parameter. Press O Key for at least 3 seconds to go to Initial Setting Level. Use the U D Keys to set the parameter. Use S Key to change the digit (default setting).
E5DC Accessories (Order Separately) ● USB-Serial Conversion Cable E58-CIFQ2 (2110) 250 263 1510 LED (RD) USB connector (type A plug) Serial connector LED (PWR) LED (SD) ● Conversion Cable E58-CIFQ2-E Conversion Cable Connecting to the E58-CIFQ2 USB-Serial Conversion Cable (2110) (1510) 250 263 1510 E58-CIFQ2 (Order separately) Note: Always use this product together with the E58-CIFQ2. Conversion Cable ● Current Transformers E54-CT1 21 15 Thru-current (Io) vs.
E5DC ● Mounting Adapters Y92F-53 (Two included.) ● Short Bars Y92S-P11 (Four included.) This accessory is not included with the product. Order it separately to mount the product to a panel. Use this product to connect between terminals (for power supplies, communications, etc.) when you use multiple E5DC Controllers. 27.5 34.7 2.4 22.5 12 24.8 11.8 9.4 0.8 3 5 ● DIN Tracks PFP-100N PFP-50N ● End Plate PFP-M 10 6.2 M4×8 pan head screw 1.8 1 50 35.5 35.3 1.8 11.5 10 M4 spring washer 7.3±0.
MEMO 63
Programmable Temperature Controller (Digital Controller) E5CC-T (48 × 48 mm) Programmable Controllers Join the E5C Series! Program up to 256 segments can handle a wide variety of applications. • Set up to 8 Programs (Patterns) with 32 Segments (Steps) Each • The white PV display with a height of 15.2 mm improves visibility. • High-speed sampling at 50 ms. • Models are available with up to 3 auxiliary outputs, up to 4 event inputs, and a transfer output to cover a wide range of applications.
E5CC-T Model Number Legend and Standard Models Model Number Legend ●Models with Screw Terminals E5CC-T @@3 @5 M -@@@ (Example: E5CC-TRX3A5M-000) −−−−−− −−− A BC D E F A Model Control outputs 1 and 2 B C D No.
E5CC-T Optional Products (Order Separately) USB-Serial Conversion Cable Model E58-CIFQ2 Front Covers Type Hard Front Cover Soft Front Cover Model Y92A-48H Y92A-48D Terminal Covers CX-Thermo Support Software Model E53-COV17 E53-COV23 (3pcs) Model EST2-2C-MV4 Note: The Terminal Covers E53-COV23 are provided with the Digital Temperature Controller. The E53-COV10 cannot be used. Refer to page 75 for the mounted dimensions.
E5CC-T Specifications Ratings Power supply voltage Operating voltage range Power consumption Sensor input Input impedance Control method Relay output Control output Auxiliary output Voltage output (for driving SSR) Linear current output Number of outputs Output specifications Number of inputs Event input External contact input specifications Transfer output Number of outputs Output specifications Setting method Indication method Bank switching Other functions Ambient operating temperature Ambient op
E5CC-T Input Ranges ●Thermocouple/Platinum Resistance Thermometer (Universal inputs) Sensor type Platinum resistance thermometer Sensor specification Pt100 Infrared temperature sensor Thermocouple JPt100 K J T E L U N R S B W PLII 10 to 70°C 60 to 120°C 115 to 165°C 120 165 140 to 260°C 2300 2300 1800 1800 1700 1700 1700 Temperature range (°C) 1600 1500 1400 1300 1300 1300 1300 1200 1100 1000 900 850 850 850 800 700 600 600 500.0 500 500.0 500.0 400.
E5CC-T Alarm Types Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (see note.) Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified. Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed. To use alarm 1, set the output assignment to alarm 1.
E5CC-T *1 *2 With set values 1, 4 and 5, the upper and lower limit values can be set independently for each alarm type, and are expressed as “L” and “H.
E5CC-T Characteristics Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max. CT input: ±5% FS ±1 digit max. Transfer output accuracy ±0.3% FS max. Influence of temperature *2 Thermocouple input (R, S, B, W, PL II): (±1% of indication value or ±10°C, whichever is greater) ±1 digit max.
E5CC-T Program Control Number of programs (patterns) Number of segments (steps) Segment setting method Segment times Alarm setting Reset operation Startup operation PID sets Number of sets Setting method Alarm SP function Program status control Wait operation Time signals Segment operation Program operation Wait method Wait width setting Number of outputs Number of ON/OFF Operations Setting method Program status output PV start Program startup operation Operation end operation Program SP shift 72 Sta
E5CC-T USB-Serial Conversion Cable Applicable OS Windows XP, Vista, or 7 Applicable software CX-Thermo version 4.61 or higher Applicable models E5@C-T Series, E5@C Series, and E5CB Series USB interface standard Conforms to USB Specification 2.0. DTE speed 38400 bps Connector specifications Computer: USB (type A plug) Digital Temperature Controller: Special serial connector Power supply Bus power (Supplied from USB host controller.)* Power supply voltage 5 VDC Current consumption 450 mA max.
E5CC-T External Connections E5CC-T Control output 1 Relay output 250 VAC, 3 A (resistive load) Voltage output (for driving SSR) 12 VDC, 21 mA Linear current output 0 to 20 mA DC 4 to 20 mA DC Load: 500 Ω max.
E5CC-T Nomenclature E5CC-T Front panel Temperature unit Operation indicators No. 1 display PV or specified monitor/setting parameter Top View of E5CC-T No. 2 display Press O Key once to go to Program Setting Level. SP or specified monitor/parameter value Top-panel Setup Tool port Press O Key for at least 3 seconds to go to Initial Setting Level. Use the UD Keys to set the parameter.
E5CC-T Accessories (Order Separately) ● USB-Serial Conversion Cable E58-CIFQ2 (2110) 250 263 1510 LED (RD) USB connector (type A plug) Serial connector LED (PWR) LED (SD) ● Terminal Covers E53-COV17 48 ● Terminal Covers E53-COV23 (Three Covers provided.) 2 3.8 48.8 10 Terminal Cover (E53-COV23) 22 44.8 9.1 ● Waterproof Packing Y92S-P8 (for DIN 48 × 48) 76 The Waterproof Packing is provided with the Temperature Controller.
E5CC-T ● Current Transformers E54-CT1 21 15 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) E54-CT1 2.8 5.8 dia. 7.5 25 Maximum continuous heater current: 50 A (50/60 Hz) Number of windings: 400±2 Winding resistance: 18±2 Ω 3 Output voltage (Eo) V (r.m.s.) 10.5 40 Two, 3.5 dia. 10 30 100V Frequency: 50 Hz ∞ 1kΩ 10 Distortion factor 10% 1 3% 1% 100mV 100Ω 10 E54-CT3 2.36 dia. 30 RL=10Ω 1 12 dia. 9 100μV 10 1 40 × 40 10 100mA 1 10 100 1,000A Thru-current (Io) A (r.m.s.
E5CC-T ● Adapter Y92F-45 Note: 1. Use this Adapter when the Front Panel has already been prepared for the E5B@. 2. Only black is available. 3. You cannot use the E58-CIFQ2 USB-Serial Conversion Cable if you use the Y92F-45 Adapter. To use the USB-Serial Conversion Cable to make the settings, do so before you mount the Temperature Controller in the panel. Fixture (Accessory) 76 4.7 69.6 to 77.
E5CC-T ● Watertight Cover ● Mounting Adapter Y92A-48N Y92F-49 21.9 14 The Mounting Adapter is provided with the Temperature Controller. Order this Adapter separately if it becomes lost or damaged. (2) 87.7 69 79.2 12 67.6 ● Protective Cover ● Protective Cover Y92A-48D Y92A-48H Note: This Protective Cover cannot be used if the Waterproof Packing is installed. This Protective Cover is soft type. It is able to operate the controller with using this cover. This Protective Cover is hard type.
Programmable Temperature Controller (Digital Controller) E5EC-T/E5AC-T (48 × 96 mm/96 × 96 mm) Programmable Controllers Join the E5C Series! Program up to 256 segments can handle a wide variety of applications. • Set up to 8 Programs (Patterns) with 32 Segments (Steps) Each • A white LCD PV display with a height of approx. 18 mm for the E5ECT and 25 mm for the E5AC-T improves visibility. • Tool ports are provided both on the top panel and the front panel.
E5EC-T/E5AC-T Model Number Legend and Standard Models Model Number Legend ●Models with Screw Terminals E5EC-T@@ 4 @ 5 M -@@@ (Example: E5EC-TRX4A5M-000) −−− − − − −−− A BC D E F E5AC-T@@ 4 @ 5 M -@@@ (Example: E5AC-TRX4A5M-000) −−−− − − −−− A BC D E F A Model Control outputs 1 and 2 B C D E F No.
E5EC-T/E5AC-T Optional Products (Order Separately) USB-Serial Conversion Cable Model E58-CIFQ2 Communications Conversion Cable Note: Always use this product together with the E58-CIFQ2. This Cable is used to connect to the front-panel Setup Tool port. Terminal Covers Model E53-COV24 (3pcs) Note: The Terminal Covers E53-COV24 are provided with the Digital Temperature Controller. Waterproof Packing Model Y92S-P9 Y92S-P10 Note: This Waterproof Packing is provided with the Digital Temperature Controller.
E5EC-T/E5AC-T Specifications Ratings A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage E5EC-T 8.7 VA max. at 100 to 240 VAC, and 5.5 VA max. at 24 VAC or 3.2 W max. at 24 VDC Power consumption E5AC-T 9.0 VA max. at 100 to 240 VAC, and 5.6 VA max. at 24 VAC or 3.4 W max.
E5EC-T/E5AC-T Input Ranges ●Thermocouple/Platinum Resistance Thermometer (Universal inputs) Sensor type Platinum resistance thermometer Sensor specification Pt100 Infrared temperature sensor Thermocouple JPt100 K J T E L U N R S B W PLII 10 to 70°C 60 to 120°C 115 to 165°C 120 165 140 to 260°C 2300 2300 1800 1800 1700 1700 1700 Temperature range (°C) 1600 1500 1400 1300 1300 1300 1300 1200 1100 1000 900 850 850 850 800 700 600 600 500.0 500 500.0 500.0 400.
E5EC-T/E5AC-T Alarm Types Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (see note.) Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified. Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed. To use alarm 1, set the output assignment to alarm 1.
E5EC-T/E5AC-T *1 *2 With set values 1, 4 and 5, the upper and lower limit values can be set independently for each alarm type, and are expressed as “L” and “H.
E5EC-T/E5AC-T Characteristics Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max. CT input: ±5% FS ±1 digit max. Potentiometer input: ±5% FS ±1 digit max. Transfer output accuracy ±0.3% FS max.
E5EC-T/E5AC-T Program Control Number of programs (patterns) Number of segments (steps) Segment setting method Segment times Alarm setting Reset operation Startup operation PID sets Number of sets Setting method Alarm SP function Program status control Wait operation Time signals Segment operation Program operation Wait method Wait width setting Number of outputs Number of ON/OFF Operations Setting method Program status output PV start Program startup operation Operation end operation Program SP shift
E5EC-T/E5AC-T USB-Serial Conversion Cable Applicable OS Windows XP, Vista, or 7 Applicable software CX-Thermo version 4.61 or higher Applicable models E5@C-T Series, E5@C Series, and E5CB Series USB interface standard Conforms to USB Specification 2.0. DTE speed 38400 bps Connector specifications Computer: USB (type A plug) Digital Temperature Controller: Special serial connector Power supply Bus power (Supplied from USB host controller.
E5EC-T/E5AC-T External Connections E5EC-T/E5AC-T 4 E5EC T (1) 5M (2) (3) (4) (5) 4 E5AC T (6) (1) 5M (2) (3) (4) (5) Terminal type (6) Terminal type Control output 1 Control output 2 Relay output 250 VAC, 5A (resistive load) Voltage output (for driving SSR) 12 VDC, 40 mA 21 mA if there are two control outputs Linear current output 0 to 20 mA DC 4 to 20 mA DC Auxiliary outputs Relay output 250 VAC, 5 A (resistive load) Voltage output (for driving SSR) 12 VDC, 21 mA Linear current output 0 to 2
E5EC-T/E5AC-T Nomenclature E5EC-T Front panel No. 1 display Temperature unit Top View of E5EC-T PV or specified monitor/parameter Operation indicators No. 2 display Top-panel Setup Tool port SP or specified monitor/parameter value No. 3 display Use S Key to change the digit (default setting). Program No., segment No., remaining segment time, or MV (valve opening). Use the U D Keys to set the parameter.
E5EC-T/E5AC-T Dimensions (Unit: mm) Controllers E5EC-T 48 (64) 60 4 1 44 96 The Setup Tool ports are on the front and top of the Digital Temperature Controller. It is used to connect the Temperature Controller to the computer to use the Setup Tool. The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection. 91 Refer to the instructions that are provided with the USB-Serial Conversion Cable for the connection procedure.
E5EC-T/E5AC-T E5AC-T (64) 60 4 1 96 x 96 91 x 91 110 Waterproof Packing (Accessory) Mounting Adapter (Accessory) The Setup Tool ports are on the front and top of the Digital Temperature Controller. It is used to connect the Temperature Controller to the computer to use the Setup Tool. The E58-CIFQ2 USB-Serial Conversion Cable is required to make the connection. Refer to the instructions that are provided with the USB-Serial Conversion Cable for the connection procedure.
E5EC-T/E5AC-T ● Terminal Covers E53-COV24 (Three Covers provided.) 2 3.8 ● Waterproof Packing Y92S-P9 (for DIN 48 × 96) The Waterproof Packing is provided with the Temperature Controller. Order the Waterproof Packing separately if it becomes lost or damaged. The degree of protection when the Waterproof Packing is used is IP66. Also, keep the Port Cover on the front-panel Setup Tool port of the E5EC-T/E5AC-T securely closed.
E5EC-T/E5AC-T ● Watertight Cover Y92A-96N (96 × 96) ● Watertight Cover Y92A-49N (48 × 96) 21.9 21.9 (2) (2) 131.7 131.7 67.6 115.6 29.4 29.4 ● Current Transformers E54-CT1 21 15 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) E54-CT1 2.8 5.8 dia. 7.5 25 Maximum continuous heater current: 50 A (50/60 Hz) Number of windings: 400±2 Winding resistance: 18±2 Ω 3 Output voltage (Eo) V (r.m.s.) 10.5 40 Two, 3.5 dia.
E5@C/E5@C-T Operation Setting Levels Diagram E5C This diagram shows all of the setting levels. To move to the advanced function setting level and calibration level, you must enter passwords. Some parameters are not displayed depending on the protect level setting and the conditions of use. Control stops when you move from the operation level to the initial setting level.
E5@C/E5@C-T E5C-T This diagram shows all of the setting levels. To move to the advanced function setting level and calibration level, you must enter passwords. Some parameters are not displayed depending on the protect level setting and the conditions of use. Press O and M Keys for at least 1 s. Protect Level Used to set protection for operations. Starting in manual mode Power ON Press O and M Keys for at least 3 s.*2 Operation in progress Level changes automatically.
E5@C/E5@C-T Operation Parameters E5@C The following pages describe the parameters set in each level. Pressing the M (Mode) Key at the last parameter in each level returns to the top parameter in that level. Some parameters may not be displayed depending on the model and other settings. Press the S Key*2 Power ON Starting in Manual Mode. Manual Control Level Press the S Key for at least 1 s. *1 C Press the O Key or the S Key for at least 1 s. *1 PID Control only 25 0 PV/MV Adjustment Level l.
E5@C/E5@C-T Monitor/Setting Item Level 25 0 Monitor/Setting Item Display 1 S Monitor/Setting Item Display 2 S Monitor/Setting Item Display 3 Monitor/Setting Item Display 4 S S Monitor/Setting Item Display 5 Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item 1 to 5 parameters (advanced function setting level). Press the O Key for at least 1 s. Advanced Function Setting Level alt3 Alarm 3 Type 2 M alh3 0.
E5@C/E5@C-T E5@C-T Some parameters may not be displayed depending on the model and other settings. Starting in manual mode Monitor/Setting Item Level 25 PF Monitor/ Power ON Manual Control Level 25 Setting Item 0 S PF Monitor/Setting Item display 2 to 5 display 1 * The monitor/setting items to display are set in the Monitor/Setting Item 1 to 5 parameters (Advanced Function Setting Level). PV/Manual MV 50.0 Press S Key.*2 Press S Key.*2 Press O or S Key for at least 1 s.
E5@C/E5@C-T Press O Key for at least 1 s. Protect Level Press O + M Key for at least 3 s. M pmov oapt 0 0 Operation/Adjustment Protect pfpt Initial Setting/ Communications Protect pmsk Setting Change Protect prlp M Move to Protect Level icpt Press O + M Key for at least 3 s. (The key pressing time can be changed in the Move to Protect Level Time parameter (Advanced Function Setting Level).) 1 M M 0 off Press O + M Key for at least 1 s.
E5@C/E5@C-T Advanced Function Setting Level init off Parameter Initialization mant Program End ON Time mani Standby Time Unit Standby Sequence Reset n-o Auxiliary Output 1 to 4 Open in Alarm hsh Heater Burnout Latch lba Heater Burnout Hysteresis 0.1 8.0 M M alfa α Integral/Derivative Time Unit o 1 AT Calculated Gain none 0.8 M at-h alm1 M alm2 M 0.
E5@C/E5@C-T Error Displays (Troubleshooting) When an error occurs, the No. 1 display or No. 2 display shows the error code. Take necessary measure according to the error code, referring the following table. Display Name Meaning The input value exceeded the control range.* The input type is not set correctly. The sensor is disconnected or shortcircuited. The sensor is not wired correctly. The sensor is not wired. s.
E5@C/E5@C-T Safety Precautions ● Be sure to read the precautions for all E5@C/E5@C-T models in the website at: http://www.ia.omron.com/. Warning Indications CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely.
E5@C/E5@C-T Precautions for Safe Use Be sure to observe the following precautions to prevent malfunction or adverse affects on the performance or functionality of the product. Not doing so may occasionally result in faulty operation. Do not handle the Digital Temperature Controller in ways that exceed the ratings. 1. This product is specifically designed for indoor use only. Do not use this product in the following places: • Places directly subject to heat radiated from heating equipment.
E5@C/E5@C-T 30.Noise may enter on the USB-Serial Conversion Cable, possibly causing equipment malfunctions. Do not leave the USB-Serial Conversion Cable connected constantly to the equipment. 31.For the E5DC, when you attach the Main Unit to the Terminal Unit, make sure that the hooks on the Main Unit are securely inserted into the Terminal Unit. 32.For the E5CC-U, when you attach the Main Unit to the socket, make sure that the hooks on the socket are securely inserted into the Main Unit. 33.
E5@C/E5@C-T ● Mounting E5EC/E5AC/E5EC-T/E5AC-T Adapter Mounting to a Panel E5GC Adapter Panel Adapter Terminal Cover (E53-COV24) Waterproof Packing Terminal Cover (E53-COV24) Panel Water Proof Packing 1. For waterproof mounting, waterproof packing must be installed on the Digital Temperature Controller. Waterproofing is not possible when group mounting several Digital Temperature Controllers. Waterproof packing is not necessary when there is no need for the waterproofing function. 2.
E5@C/E5@C-T • Removing a Unit Pull down on the DIN Track Hook with a flat-blade screwdriver and lift up the Unit. Mounting the DIN Track Attach the DIN Track to the inside of the control panel with screws to at least three locations. • DIN Track (sold separately) PFP-50N (50 cm) and PFP-100N (100 cm) Install the DIN Track vertically to the ground. Removing the Main Unit Press in the two hooks on the Main Unit and remove the Main Unit from the Terminal Unit.
E5@C/E5@C-T Attaching the End Cover E5DC 4. Secure the End Cover so that the double-sided tape is firmly attached. 1. Install the E5DC in a panel. 2. Peel off the release paper from the double-sided tape on the End Cover. Double-sided tape Removing the Digital Temperature Controller from the case E5GC You can use the Y92F-55 Draw-out Jig to remove the interior body of the Digital Temperature Controller from the case to perform maintenance without removing the terminal wiring.
E5@C/E5@C-T ● Precautions when Wiring • Separate input leads and power lines in order to prevent external noise. • Use a shielded, AWG24 to AWG18 (cross-sectional area of 0.205 to 0.8231 mm2) twisted-pair cable. Use a shielded, AWG24 to AWG14 (cross-sectional area of 0.205 to 2.081 mm2) twisted-pair cable for the E5CC-U. The stripping length is 6 to 8 mm for the E5CC, E5EC, E5AC, E5DC, or E5CC-T and 5 to 6 mm for the E5CC-U.
Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron).
OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No.