New Product Slim I/O Relay Global standard size, low profile slim I/O relay with width 6.2 mm, slim I/O solid state relay For the recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions on page 20. Slim I/O Relay Types G2RV-SR series mounted relay: electromagnetic relay ...... from page 2 G3RV-SR series mounted relay: solid state relay ................
Slim I/O Relay G2RV-SR G2RV-SR Global standard size, low profile slim I/O relay with width 6.2 mm G3RV-SR • Realized about 25% lower profile than conventional products, contributing to further miniaturization of the control panel. • Realized opening and closing ability with one pole 6 A slim shape. • Micro load products for one pole 50 mA using Au-plated contacts for small load switching also available.
G2RV-SR Model Number Structure Model Number Legend (1) (2) (3) (4) (5) (6) (1) Basic model name G2RV: Slim I/O Relay (2) Sub type SR: Slim relay + integrated low profile socket (3) Terminal (wire connection) 50: Push-In Plus Terminal 70: Screw terminal (5) Contact structure Blank: Standard AP: Microloads (4) Latching lever (test switch) 0: Without latching lever 1: With latching lever (6) Rated input voltage 12, 24 VDC 24, 48 VAC/VC 100, 110, 200, 230 VAC G2RV-SR G2RV-SR @@ @ - @ @ Ordering Inf
G2RV-SR Relay for Maintenance G2RV-SR Model Number Legend G2RV-1 - S @ - @ - G @ (1) (2) (3) (4) (5) (1) No.
G2RV-SR Specifications Ratings Must operate voltage Rated current Rated input voltage AC 50 Hz DC 60 Hz Must release voltage Percentage of the rated voltage Power consumption Maximum allowable voltage AC (VA) Percentage of the rated voltage DC (mW) 12 VDC – – 27.9 mA – Approx. 300 mW 24 VDC – – 13.5 mA – Approx. 300 mW 24 VAC/VDC 12.5 mA 12.6 mA 12.6 mA Approx. 0.5 VA Approx. 300 mW 48 VAC/VDC 5.9 mA 6.1 mA 5.2 mA 100 VAC 5.9 mA 6.0 mA – 110 VAC 5.9 mA 5.
G2RV-SR Approved standards G2RV-SR UL508 (file No.E41643) Model Contact form G2RV-SR series Operation coil ratings 12 to 48 VDC 24 to 230 VAC SPDT Contact ratings Operations 6 A at 250 VAC (Resistive load) 6 A at 30 VDC (Resistive load) 2 A at 400 VAC (Resistive load)* * If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12). 6,000 12 mm 12 mm 12 mm TÜV (EN 61810-1) \ Model Contact form SPDT Operations 50,000 50,000 6,000 12 mm
G2RV-SR Dimensions (unit: mm) Slim I/O Relay + socket Push-In Plus Terminal Block Terminal Arrangement/Internal Connection Diagram (TOP VIEW) 12 VDC (+) Input circuit A1 G2RV-SR Models without latching lever (without test switch) G2RV-SR500 78 max. G2RV-SR500-AP A2 G2RV 3.4 (–) 74.5 74.1 Other voltage 35.25 18.78 (5.05) Input circuit A1 G2RV 12 A2 14 11 78.77 G3RV-SR 90 max. 35.3 24 VDC (+) Input circuit 12 A1 14 A2 G2RV 11 (–) : Diode bridge (5.05) : Light emitting diode 18.
G2RV-SR Screw terminal G2RV-SR Models without latching lever (without test switch) G2RV-SR700 G2RV-SR700-AP Terminal Arrangement/Internal Connection Diagram (TOP VIEW) 12 VDC (+) 78 max. G2RV 3.4 Input circuit A1 74.5 A2 (–) Other voltage 74.1 35.18 Input circuit 18.71 (5.05) A1 G2RV 12 A2 14 11 78.77 35.3 90 max. G3RV-SR 24 VDC (+) Input circuit 12 A1 14 A2 G2RV 11 (–) : Diode bridge (5.05) 18.71 : Light emitting diode 35.18 6.2 max. 51.65 56.
G2RV-SR Relay for maintenance 5.2 max. G2RV-SR Models without latching lever G2RV-1-S-G G2RV-1-S-AP-G 30.5 max. Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 33 max. 16.2 0.5 14 11 12 A1 A2 G3RV-SR 1.8 (Input circuit) 2.4 3.5 5.04 5.04 22 3 Models with latching lever (test switch) G2RV-1-SI-G 30.5 max. Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) (Input circuit) 36 max. 14 11 12 16.2 1.8 A1 A2 Common Precautions 5.2 max. 0.5 2.4 5.04 5.
Slim I/O Solid State Relay G2RV-SR G3RV-SR Global standard size, low profile type slim I/O solid state relay with width 6.2 mm. G3RV-SR • Realized about 25% lower profile than conventional products, contributing to further miniaturization of the control panel. • Optimal slim, high frequency, high-speed opening and closing SSR (solid state relay). • Realized a slim shape with a switching capacity up to 3 A (DC), and 2 A (AC).
G3RV-SR Model Number Structure Model Number Legend (1) (2) (3) (4) (5) (1) Basic model name G3RV: Slim I/O Solid State Relay (2) Sub type SR: Slim solid relay + integrated low profile socket (3) Terminal (wire connection) 500: Push-In Plus Terminal 700: Screw terminal (4) Output voltage specification A : AC output (triac) zero cross function available AL : AC output (triac) zero cross function not available D : DC output (MOS FET) G2RV-SR G3RV-SR @ @ @ - @ @ (5) Rated voltage input 12, 24 VDC 24,
G3RV-SR Ordering Information Terminal (wire connection) Applicable output load Zero cross function Rated input voltage (V) G2RV-SR DC AC/DC DC load — AC DC AC/DC Push-In Plus Terminal Yes G3RV-SR AC AC load DC AC/DC No AC Common Precautions DC AC/DC DC load — AC DC AC/DC Screw terminal Yes Common Accessories AC AC load DC AC/DC No AC Note: Sockets are not sold individually.
G3RV-SR Solid state relay for maintenance G2RV-SR Model Number Legend G3RV-@ @ S @ @ (1) (2) (3) (4) (1) Output voltage specification D: DC output 2: AC output (5) (3) Terminal S: Plug-in type (4) Zero cross functions Blank: Zero cross function available L: Zero cross function not available (2) Rated current 02: AC output 2 A 03: DC output 3 A (5) Rated input voltage Number: 12, 24, 48 VDC List of Models Rated output Load * Rated input voltage (socket) 12 VDC 24 VDC 24 VAC/VDC Model G3RV-202S DC12
G3RV-SR Specifications Rating (ambient temperature 25°C) G2RV-SR Input G3RV-SR700/500-A series Rated current Rated input voltage AC 50 Hz Input voltage DC 60 Hz Must operate voltage 12 VDC – – 15.0 mA 10.8 V max. 24 VDC – – 12.0 mA 21.6 V max. 24 VAC/VDC 11.3 mA 11.4 mA 11.0 mA 21.6 V max. 48 VAC/VDC 6.8 mA 6.9 mA 6.0 mA 43.2 V max. 100 VAC 6.2 mA 6.2 mA – 90 V max. 110 VAC 6.2 mA 6.2 mA – 99 V max. 200 VAC 6.7 mA 7.9 mA – 180 V max. 230 VAC 7.5 mA 8.
G3RV-SR Characteristics G3RV-SR700/500-A G3RV-SR700/500-AL G3RV-SR700/500-D Operate time 1/2 cycle of load power supply +1 ms max. 3 ms max. 6 ms max. Release time 60 ms max. 60 ms max. 60 ms max. Output ON voltage drop 1.6 V (RMS) max. Output ON resistance – 0.3 Ω max. (at 24 VDC) – 5 mA max. (at 200 VAC, 50/60 Hz) 10 µA max. (at 24 VDC) Insulation resistance 100 MΩ min.
G3RV-SR Engineering Data Load current vs. ambient rated temperature Product mounting spacing 10 mm (Separate Mounting) Close mounting (up to 5 units *) 5 Load current (A) Load current (A) G2RV-SR G3RV-SR700/500-A(L) series 4 5 4 3 3 2 2 1 1 0 −30 −20 0 20 25 40 55 60 80 0.
G3RV-SR Dimensions (unit: mm) Solid state relay + socket Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 12 VDC G2RV-SR Push-In Plus Terminal Block G3RV-SR500 (+) Input circuit 78 max. A1 G3RV A2 A2– 3.4 (5.05) (–) INPUT 74.5 74.1 A1+ 13 (+) 35.25 18.78 OUTPUT 14 (–) 12 14 13 78.77 90 max. 35.3 24 VDC (+) Input circuit G3RV-SR The information in parentheses in for a DC output. A1 G3RV A2 (–) A2– INPUT (5.05) A1+ 18.78 6.2 max. 35.25 OUTPUT 14 (–) 59.
G3RV-SR Screw terminal G3RV-SR700 G2RV-SR Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 12 VDC 78 max. (+) Input circuit A1 3.4 74.5 G3RV 74.1 35.18 (5.05) A2 A2– 18.71 (–) INPUT A1+ 13 (+) OUTPUT 14 (–) G3RV-SR 78.77 35.3 90 max. The information in parentheses in for a DC output. 12 14 13 24 VDC (+) Input circuit A1 (5.05) 18.71 G3RV 35.18 A2 6.2 max. (–) 51.65 56.
G3RV-SR Solid state relay for maintenance Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) G3RV-D03SL (input circuit) Input 30.5 max. Load G2RV-SR G3RV-D03SL G3RV-202S(L) 33 max. 15.8 14 1.8 3.5 13 A1 A2 G3RV-202S(L) (input circuit) 2.4 22 5.04 3 Input 5.2 max.
G2RV-SR/G3RV-SR Safety Precautions Be sure to read the Safety Precautions for All Relays in the website at the following URL: http://www.ia.omron.com/. G2RV-SR Format of Warning Indications WARNING Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally, there may be significant property damage.
G2RV-SR/G3RV-SR Precautions for Safe Use G2RV-SR Transport • Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance. • Do not drop the product or subject it to abnormal vibration or shock during transportation or mounting. Doing so may result in deterioration of performance, malfunction, or failure. • Do not transport the product without it being packaged. Doing so may result in damage, malfunction, or failure.
G2RV-SR/G3RV-SR Precautions for Correct Use G2RV-SR • Do not use or store the product in the following locations. Doing so • When replacing relays, there is a possibility the relay will pop out may result in damage, malfunction, or deterioration of performance and fall. Take care to prevent the relay from falling during characteristics. replacement.
G2RV-SR/G3RV-SR Screw Terminal 3. Recommended ferrules and Crimp Tools Recommended ferrules • Screw terminal Stripping Ferrules Recommended ferrules length Conduct (mm) length Wago (Ferrules Phoenix Contact Weidmuller (mm2) (AWG) (mm) product product product used) 0.25 24 0.34 22 0.5 20 0.75 18 1/1.25 18/17 10 AI 0,25-8 H0.25/12 12 AI 0,25-10 --- 216-301 8 10 AI 0,34-8 H0.34/12 10 12 AI 0,34-10 --- 8 10 AI 0,5-8 H0.5/14 216-201 10 12 AI 0,5-10 H0.
G2RV-SR/G3RV-SR Method of operation of the latching lever (test switch) G2RV-SR Incorrect Example Countermeasure 1 Countermeasure 2 Recommended height of the duct is 1/2 or less of the height of the SSR Duct or other object blocking airflow Duct or other object blocking airflow Open protective cover Vertical Direction Duct or other object blocking airflow G3RV-SR Keep the protective cover open
G2RV-SR/G3RV-SR For G2RV-SR/G3VR-SR Common Accessories (order separately) Short Bars Appearance No. of poles Pitch Colors 2 Maximum energizing current PYDN-6.2-020@ 3 6.2 mm Minimum order (Quantity) Model * Red (R), Blue (S), Yellow (Y) 4 10 20 G2RV-SR Ordering Information PYDN-6.2-030@ PYDN-6.2-040@ 10 32 A PYDN-6.2-100@ PYDN-6.2-200@ Note: Use for wiring to the adjacent socket. * Replace the box (@) in the model number with the code for the covering color.
G2RV-SR/G3RV-SR Applicable Cables G2RV-SR Name Appearance Cables with Loose Wires P2RV-A@C 8 I/O points 1,000 P2RV-A100C 2,000 P2RV-A200C 3,000 P2RV-A300C 5,000 P2RV-A500C 1,000 P2RV-4-100C 2,000 P2RV-4-200C L 32 output points PLC I/O Units with MIL connectors (1:4) CJ1W-OD232/OD262, etc.
G2RV-SR/G3RV-SR Name Appearance 32 input points End B Device end PLC interface unit end 32 output points Schneider Electric PLC Connecting Cables P2RV-@C-SCH-@ L 300 16 output points L 300 32 input points Siemens PLC Connecting Cables P2RV-@C-SIM-@ L 300 16 input points 300 32 input points 32 output points L 300 P2RV-100C-SCH-A 2,000 P2RV-200C-SCH-A 3,000 P2RV-300C-SCH-A 5,000 P2RV-500C-SCH-A 500 P2RV-050C-SCH-B 1,000 P2RV-100C-SCH-B 2,000 P2RV-200C-SCH-B 3,000 P2RV-300C
G2RV-SR/G3RV-SR PLC interface unit Ratings / characteristices G2RV-SR Rated voltage 30 VAC/DC Rated current 0.5 A/poles, 2 A/unit Ambient operating temperature −40 to 55°C Vibration resistance Shock resistance Destruction 10 to 55 to 10 Hz, single amplitude 0.75 mm (double amplitude 1.5 mm) Malfunction 10 to 55 to 10 Hz, single amplitude 0.75 mm (double amplitude 1.5 mm) Destruction 300 m/s2 Malfunction 100 m/s2 Electrical schematic Input P2RVC-8-I-@-1 (PNP) 1....................
G2RV-SR/G3RV-SR Dimensions (unit: mm) PLC interface unit G2RV-SR Push-IN P2RVC-8-I-5(-1) P2RVC-8-O-5(-1) 49.60 67.16 7×6.20 29 Screw P2RVC-8-I-7-1 P2RVC-8-O-7-1 67.16 12.68 7×6.20 29 Common Precautions 49.60 G3RV-SR 12.
G2RV-SR/G3RV-SR (Except for PLC interface unit) Common Accessories (order separately) G2RV-SR Dimensions (unit: mm) Short Bars PYDN-6.2-@@ (6.2 mm) Pitch 2 L No. of poles 1.20 6.2 mm 9 14 6.20 L (Length) 2 12.4 3 18.6 4 24.8 10 62 20 124 Colors Model * Maximum carry current PYDN-6.2-020@ Red (R) Blue (S) Yellow (Y) PYDN-6.2-030@ PYDN-6.2-040@ 32 A PYDN-6.2-100@ PYDN-6.2-200@ Note: Use the Short Bars for crossover wiring within one Socket or between Sockets.
Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron).
OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No.