Datasheet
G9SE
2
Specifications
Ratings
Power Input
Outputs
Characteristics
Model
G9SE-201 G9SE-401 G9SE-221-T@
Item
Rated supply voltage 24 VDC
Operating voltage range –15% to 10% of rated supply voltage
Rated power consumption
*1
*1
Power consumption of loads not included.
3 W max. 4 W max.
Model
G9SE-201 G9SE-401 G9SE-221-T@
Item
Safety output
OFF-delayed Safety output
Contact output
250 VAC 5 A 30 VDC 5 A (resistance load)
Auxiliary output PNP transistor output Load current: 100 mA DC max.
Model
G9SE-201 G9SE-401 G9SE-221-T@
Item
Operating time (OFF to ON state)
*1
*1
The operating time is the time it takes for the safety contact to close after the safety inputs and feedback-reset input are turned ON. Not includes bounce time.
100 ms Max.
*2
*2
This is in normal operation. When executing non-regular self-diagnosis for Safety output circuit, G9SE operating time become 500 ms max..
Response time (ON to OFF state)
*3
*3
The response time is the time it takes for the safety main contact to open after the safety input is turned OFF. Includes bouncetime.
15 ms Max.
Accuracy of OFF-delay time
Within plus or minus 10% of
the set value
Inputs
Input current 5 mA Min.
ON voltage 11 VDC Min.
OFF voltage 5 VDC Max.
OFF current 1 mA Max.
Maximum cable length 100 m Max.
Reset input time 250 ms Min.
Contact
outputs
Contact resistance
*4
*4
This is initial value using the voltage-drop method with 1 A at 5 VDC.
100 m
Mechanical durability 5,000,000 operations Min.
Electrical durability 50,000 operations Min.
Switching specification Inductive load
(IEC/EN60947-5-1)
AC15: 240 VAC 2 A
DC13: 24 VDC 1.5 A
Minimum applicable load 24 VDC 4 mA
Conditional short-circuit current
(IEC/EN60947-5-1)
100 A
*5
*5
Use an 8 A fuse that conforms to IEC 60127 as a short-circuit protection device. This fuse is not included with the G9SE.
Pollution degree 2
Over voltage category (IEC/EN60664-1) Safety output: Class III, the others: Class II
Insulation
specification
Impulse withstand
voltage
(IEC/EN60947-5-1)
Between
input and
output
6 kV
Between
different
poles of
output
6 kV (between 13-14/23-24 and 33-34/43-44 (37-38/47-48))
4 kV (between 13-14 and 23-24, between 33-34 (37-38) and 43-44 (47-48))
Dielectric strength
Between
input and
output
2,200 VDC
Between
different
poles of
output
1,500 VAC
Insulation resistance 100 M
Vibration resistance
*6
*6
Condition: G9SE is mounted to mounting surface with screw and the screw mounting attachment. In the case of DIN rail mounting, mount DIN rail with G9SE to the place without big vibration.
(Amplitude guideline: Less than 0.15 mm half amplitude (0.3 mm double amplitude))
Frequency:10 to 55 to 10 Hz
Amplitude:0.35 mm half amplitude (0.7 mm double amplitude)
Mechanical shock
resistance
*6
Destruction 300 m/s
2
Malfunction 100 m/s
2
Surrounding air temperature –10 to 55C (No freezing or condensation)
Ambient humidity 25% to 85%RH
Degree of protection IP20
Weight approx. 150 g approx. 180 g