Datasheet
12 Multifunction Counter H7BX
■ Operation in Run Mode
Present value
Set value
Present value
Set value
Present value
Set value 1
Present value
Set value 2
Total count value
Present value
Set value
Batch count value
Batch count set
value
Dual count value
Dual count set
value
CP1 present value
CP2 present value
• Present Value
Shows the present count value.
• Set Value (Set Value 1, Set Value 2)
Set the set value.
When the present value reaches the set
value, signals are output according to the
specified output mode.
• Present Value/Set Value
Same as 1-stage counter.
• Total Count Value
Shows the present total count value.
• Present Value/Set Value
Same as 1-stage counter.
• Batch Count Value
Shows the number of times the count has
been completed for the present value.
• Batch Count Set Value
Set the batch count set value. When the
batch count value reaches the batch
count set value, batch output (OUT1)
turns ON.
• Dual Count Value
Shows the sum of the CP1 present value and CP2 present value when the dual count
calculating mode is ADD and shows the value obtained by subtracting the CP2 present
value from the CP1 present value when the dual count calculating mode is SUB.
• Dual Count Set Value
Set the dual count set value. When the dual count value reaches the dual count
set value, signals are output according to the specified output mode.
• CP1/CP2 Present Value
Show the present count values for CP1 and CP2 present values respectively.
• Set the number for each digit with the Keys.
● 1-stage Counter
● 2-stage Counter
● Total and Preset Counter
● Batch Counter
● Dual Counter
Up