Datasheet
18 Multifunction Counter H7BX
■ Reset Function List
Function
1-stage/2-stage
counter
Total and preset counter Batch counter Dual counter
Display in run
mode
Present value/set
value (1, 2)
Present value/
set value
Total count
value
Present value/
set value
Batch count
value/batch
count set value
Dual count
value/dual count
set value
CP1 present
value/CP2
present value
Reset/reset 1
Present value and
output reset.
Present value and output reset. Present value and output reset. Only the CP1 present value is reset.
Total reset/reset 2 No effect. Only the total count value is reset.
Batch count value and batch output
reset.
Only the CP2 present value is reset.
Reset Key
Present value and
output reset.
Present value and
output reset.
Present value,
total count value,
and output reset.
Present value and
output reset.
Present value,
batch count value,
output and batch
output reset.
CP1 present value, CP2 present
value, dual count value, and output
reset.