22 Multifunction Counter H7BX
Operation in Run Mode
Output Mode Settings
Output mode
setting
Upper and
lower limit
(HI-LO)
ON condition for OUT1: Measurement value OUT1 set value
ON condition for OUT2: Measurement value OUT2 set value
Area
(AREA)
Upper limit
(HI-HI)
ON condition for OUT1: Measurement value OUT1 set value
ON condition for OUT2: Measurement value OUT2 set value
Lower limit
(LO-LO)
ON condition for OUT1: Measurement value OUT1 set value
ON condition for OUT2: Measurement value OUT2 set value
Measurement value
Measurement value
OUT1 set value
Measurement value
OUT2 set value
Measurement Value
Displays the currently measured value.
OUT1/OUT2 Set Value
Set OUT1 set value and OUT2 set value. The
measurement value is compared to OUT1 set value
and OUT2 set value and output is made according to
the selected output mode.
Set the number for each digit with the Keys.
Up
OUT1
OUT2
Measurement value
(Upper-limit)
OUT2 set value
(Lower-limit)
OUT1 set value
OUT1
OUT2
Measurement value
OUT2 set value
OUT1 set value
Condition
OUT1 set value OUT2
set value
OUT1 set value > OUT2
set value
ON condition
for OUT1
OUT1 set value
Measurement value OUT2
set value
OUT2 set value
Measurement value OUT1
set value
ON condition
for OUT2
Measurement value < OUT1
set value or Measurement
value > OUT2 set value
Measurement value < OUT2
set value or Measurement
value > OUT1 set value
OUT1
OUT2
Measurement value
(Upper-limit)
OUT2 set value
(Upper-limit)
OUT1 set value
OUT1
OUT2
Measurement value
(Lower-limit)
OUT2 set value
(Lower-limit)
OUT1 set value