Datasheet

24 Multifunction Counter H7BX
Key Protect Level
When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by
specifying the key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/
OFF status of the key protect switch after the H7BX is mounted to the panel.
Note: Changing to configuration selection mode and function selection mode.
Self-diagnostic Function
The following displays will appear if an error occurs.
Note 1. Display flashes (1-second cycles).
2. Occurs when the present value or the total count value goes below 99,999
3. Occurs when the present value reaches 999,999 under the following conditions:
The output mode is K-2, D, L, or H.
The H7BX is set for dual counter operation.
4. Except when the H7BX is used as a tachometer.
5. Includes the case where the EEPROM has reached its overwrite lifetime.
Level Meaning
Details
Changing mode
(See note.)
Switching display in
run mode
Reset Key
Up/Down Keys
(Up Keys for 6-digit
models)
KP-1
(default setting)
No Yes Yes Yes
KP-2 No Yes No Yes
KP-3 No Yes Yes No
KP-4 No Yes No No
KP-5 No No No No
Main display Sub-display Error Output status Correction method Set value after reset
-----
(See note 1.)
No change
Present value underflow
(See note 2.)
No change
Either press the Reset
Key or turn ON reset
input.
No change
fffff
(See note 1.)
No change
Present value overflow
(See note 3.)
No change
Either press the Reset
Key or turn ON reset
input. (See note 4.)
No change
e1
Not lit CPU OFF
Either press the Reset
Key or reset the power
supply.
No change
e2
Not lit Memory error (RAM) OFF Reset the power supply. No change
e2 sum
Memory error (EEP)
(See note 5.)
OFF
Reset to the factory
settings using the Reset
Key.
0