Datasheet

8 Multifunction Counter H7BX
Operating Procedures
Setting Procedure Guide
Settings for Counter Operation
(1-stage/2-stage Counter, Total and Preset Counter, Batch Counter, Dual Counter)
Setting for Tachometer Operation
(H7BX-AW@ only)
1
OFF
ON
2345678
Using Basic Settings Only
Basic Settings
Using Input Modes Not Given Above (Up/Down A,
Up/Down B, Up/Down C) , Output Modes
(R/P/Q/A/K-2/D/L/H), or (OUT2) Output Time
Performing Advanced Settings: Dual Count Calculating
Mode, Output 1 Time, Decimal Point Position, Prescale
Value, Display Color, or Key Protect Level
Counting speed (30 Hz, 5 kHz)
Input mode (UP, DOWN)
Output mode (N, F, C, K-1)
One-shot output time (0.5 s, 0.05 s)
Reset input signal width (20 ms, 1 ms)
NPN/PNP input mode (NPN, PNP)
Note: The default setting is for a 1-stage preset counter. (For models with a 2-stage setting, the default is a 2-stage preset counter.)
The settings can be made
easily with the DIP switch.
For details on the setting
methods, refer to page 9.
Set all functions with the operation keys.
For details on the setting methods,
refer to page 10.
Settings other than the basic functions above
can be performed with the operation keys.
For details on the setting methods,
refer to page 10.
1
OFF
ON
2345678
Using Basic Settings Only
Basic Settings
Performing Advanced Settings: Decimal Point Position, Prescale Value, Auto-zero Time, Startup Time,
Display Color, or Key Protect Level
Counting speed (30 Hz, 10 kHz)
Output mode (HI-LO, AREA, HI-HI, LO-LO)
Average processing (OFF, 2, 4, 8 times)
NPN/PNP input mode (NPN, PNP)
Note: The default setting is for a 2-stage preset counter.
Settings other than the basic functions above can be
performed with the operation keys.
For details on the setting methods, refer to page 20.
The settings can be made
easily with the DIP switch.
For details on the setting
methods, refer to page 19.