Self-powered Totalizer New H7E CSM_H7E_-N_DS_E_9_2 Compact Economical Totalizer with High Visibility Available with Backlit LCD Display • Large display with 8.6-mm character height. • Includes new models with backlight for improved visibility in dimly lit places. (Requires 24-VDC power supply.) • Black and light-gray cases now available. • PNP/NPN universal DC voltage input types now available. • Battery is replaceable for Totalizer reuse and conservation of the environment.
Self-powered Total Counter New H7EC • Eight-digits, counting range 0 to 99999999. • Dual input speed: 30 Hz ←→ 1 kHz (except for AC/DC multivoltage input models) For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure ■ Model Number Legend Note: Some configurations are not available. H7EC - N 1 2 3 1. Count Input None: No-voltage input V: PNP/NPN universal DC voltage input FV: AC/DC multi-voltage input 2.
New H7EC Specifications ■ General Item H7EC-NV-@ H7EC-NV-@H H7EC-NFV-@ Operating mode Up type Mounting method Flush mounting External connections Screw terminals, optional Wire-wrap Terminals (see note 1) Reset External/Manual reset Number of digits 8 Count input PNP/NPN universal DC voltage in- AC/DC multi-voltage input put H7EC-N-@ No-voltage input Display 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 2) Max.
New H7EC ■ Characteristics Item H7EC-NV-@ H7EC-NV-@H H7EC-NFV-@ H7EC-N-@ Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts, and between the backlight power supply terminal and count input terminals/reset terminals for backlight models 100 MΩ min. (at 500 VDC) between 100 MΩ min.
New H7EC Connections ■ Terminal Arrangement Bottom view: View of the Total Counter rotated horizontally 180° Backlight Model No-backlight Model Backlight 24 VDC Count input Count input Reset input Reset input ■ Connections H7EC Total Counter PNP/NPN Universal DC Voltage Input Model With Backlight 1. Contact Input (Input by a Relay or Switch Contact) Relay Relay 2.
New H7EC PNP/NPN Universal DC Voltage Input Model Without Backlight No-voltage Input Model 1. Contact Input (Input by a Relay or Switch Contact) 1. Contact Input (Input by a Relay or Switch Contact) Relay Relay Relay Relay Input Input Reset Reset or Switch or Switch Terminals 2 and 4 are internally connected. or Switch or Switch Note: Use Relays and Switches that have high contact reliability because the current flowing from terminals 1 or 3 is small.
New H7EC Operation ■ Operating Modes H7EC Total Counter Incrementing Operation (Up) Reset Count input Full-scale (Full-scale −1) Counting display values Nomenclature Front view H7EC Reset Key Reset the count value. Not operable under key-protect. Counting speed switch Key-protect Switch For all models except for H7EC-NFV-@. If the counting speed setting is changed, the present value will not be held and so press the Reset Key on the front panel.
New H7EC Dimensions Note: All units are in millimeters unless otherwise indicated. H7EC-N M3.5 terminal screw Panel Cutout Separate mounting 40 min. 45+0.5 0 22.2+0.5 0 Dimensions with Y92F-34 Flush Mounting Bracket Dense mounting +1.0 (48 Units − 2.5) 0 22.2+0.
Self-powered Time Counter New H7ET • Seven digits, time range 0 to 3999d23.9h. • Dual time range: 999999.9 ←→ 3999d23.9h or 999h59m59s ←→ 9999h59.9m For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure ■ Model Number Legend Note: Some configurations are not available. H7ET - N 1 2 3 4 1. Count Input None: No-voltage input V: PNP/NPN universal DC voltage input FV: AC/DC multi-voltage input 2.
New H7ET Specifications ■ General Item H7ET-NV-@ H7ET-NV-@H H7ET-NFV-@ H7ET-N-@ H7ET-NV1-@ H7ET-NV1-@H H7ET-NFV1-@ H7ET-N1-@ Operating mode Accumulating Mounting method Flush mounting External connections Screw terminals Reset External/Manual reset Display 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 1) Number of digits 7 Time range 0.0h to 999999.9h ←→ 0.0h to 3999d23.9h (switchable with switch) 0s to 999h59min59s ←→ 0.0min to 9999h59.
New H7ET ■ Characteristics Item H7ET-NV@-@ H7ET-NV@-H@ H7ET-NFV@-@ H7ET-N@-@ Time accuracy ±100 ppm (25°C) Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts, and between the backlight power supply and timer input terminals/reset terminals for backlight models 100 MΩ min.
New H7ET Connections ■ Terminal Arrangement Bottom view: View of the Time Counter rotated horizontally 180° Backlight Model No-backlight Model Backlight 24 VDC Timer input Timer input Reset input Reset input ■ Connections H7ET Time Counter PNP/NPN Universal DC Voltage Input Model With Backlight 1. Contact Input (Input by a Relay or Switch Contact) Relay Relay 2.
New H7ET PNP/NPN Universal DC Voltage Input Model Without Backlight No-voltage Input Model 1. Contact Input (Input by a Relay or Switch Contact) Relay 1. Contact Input (Input by a Relay or Switch Contact) Relay Relay Input Input Relay Reset Reset Terminals 2 and 4 are internally connected. or Switch or Switch or Switch or Switch 2.
New H7ET Operation ■ Operating Modes H7ET Time Counter Incrementing Operation (Up) Reset Timer input Internal clock timer value Full-scale (Full-scale −0.1 (1)) Timer display values Nomenclature Front view Location to Attach Unit Label Attach the correct unit label for the time range that is set. Reset Key Reset the count value. Not operable under key-protect. H7ET Time-range switch If the time-range setting is changed, the present value will not be held and so press the Reset Key on the front panel.
New H7ET Dimensions Note: All units are in millimeters unless otherwise indicated. H7ET-N Panel Cutout Separate mounting 40 min. 45+0.5 0 Dimensions with Y92F-34 Flush Mounting Bracket 22.2+0.5 0 Dense mounting +1.0 (48 Units − 2.5) 0 22.2+0.5 0 Waterproofing is not possible for dense mounting • When mounting, insert the Counter into the cutout, insert the adapter from the back and push in the Counter while making the gap between the front panel and the cutout panel as small as possible.
Self-powered Tachometer New H7ER • Revolutions displayed up to five digits. • Dual revolution display according to encoder resolution used; 1000 s–1/1000 min–1 or 1000.0 s–1 /1000.0 min–1 • Switchable dual revolution display type available (-NV1 models); extended up to 10000 min–1 For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure ■ Model Number Legend Note: Some configurations are not available.
New H7ER Specifications ■ General Item H7ER-NV-@ H7ER-NV-@H H7ER-N-@ H7ER-NV1-@ H7ER-NV1-@H Operating mode Up type Mounting method Flush mounting External connections Screw terminals, Wire-wrap Terminals (see note 3) Display 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 4) Number of digits 4 Count input PNP/NPN universal DC voltage input Max. counting speed 1 kHz 10 kHz Max.
New H7ER ■ Characteristics Item H7ER-NV@-@ H7ER-NV@-@H H7ER-N-@ Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying 100 MΩ min.
New H7ER Connections ■ Terminal Arrangement Bottom view: View of the Tachometer rotated horizontally 180° Backlight Model No-backlight Model Backlight 24 VDC Pulse input Pulse input ■ Connections H7ER Tachometer Note: Select input transistors according to the following: Dielectric strength of the collector ≥ 50 V Leakage current < 100 µA (1 µA for no-voltage input model) PNP/NPN Universal DC Voltage Input Models With Backlight No-voltage Input Model Transistor Input Transistor Input (Open Collecto
New H7ER Operation ■ Operating Modes H7ER Tachometer Incrementing Operation Within Unit Time (Up) Count period Count period 0.25 s (1 s) (1 s) Internal gate Display refreshed Counter reset Refresh Internal count value Number display Previous count value display Display refreshed every 1.25 s Display refreshed every 1.
New H7ER Dimensions Note: All units are in millimeters unless otherwise indicated. H7ER-N Panel Cutout Separate mounting 40 min. 45+0.5 0 22.2+0.5 0 Dimensions with Y92F-34 Flush Mounting Bracket Dense mounting +1.0 (48 Units − 2.5) 0 22.2+0.5 0 Waterproofing is not possible for dense mounting • When mounting, insert the Counter into the cutout, insert the adapter from the back and push in the Counter while making the gap between the front panel and the cutout panel as small as possible.
PCB-mounting Counters H7E@-N@P • Dedicated for use on PCB. • Total Counters and Time Counter available. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure ■ Model Number Legend H7E -N 1 P 2 1. Function C: Total Counter T: Time Counter 2. Max. Counting Speed for H7EC Models None: 1 kHz L: 30 Hz Ordering Information ■ PC Board-use Counters Count input Display Total counter Time counter Max.
H7E@-N@P Specifications ■ General Item Total Counter H7EC-NP Time Counter H7EC-NLP Operating mode Up type Mounting method Direct mounting on PC Board or mounting on 28-pin socket Reset External reset, Power-OFF reset Number of digits 8 Time range --- Max. counting speed 1 kHz Count/Timer input No-voltage input Display 7-segment LCD (character height: 8.6 mm) Case color Transparent Approved standard UL863, CSA C22.2 No.14 H7ET-NP 7 0.0h to 999999.
H7E@-N@P Connections ■ Terminal Arrangement 3-VDC external power supply H7EC-N@P Reset input Bottom view 28 26 H7ET-NP Reset input Count input 17 15 Timer input 17 15 Top view COUNTS 1 3 Bottom view 28 26 Top view omronH7EC 3-VDC external power supply omronH7ET COUNTS 1 3 12 14 12 14 ■ Connections Power Supply and Battery Connections Battery Connections Backup Circuit for Protection Against Power Failure 3-V battery H7E@-N@P H7E@-N@P 3-V battery When designing a circuit, keep the
H7E@-N@P Input Connections Solid State Input Open-collector Transistor Input Input Connection Contact Input H7E@-N@P Relay Relay H7E@-N@P Reset input Reset input Count/Timer input Or Or Count/Timer input TTL or C-MOS IC Input TTL or C-MOS IC H7E@-N@P TTL or C-MOS IC When the H7EC-NP is used, relay chattering may be counted. Use the H7EC-NLP, one of the low-speed input models.
H7E@-N@P Dimensions Note: All units are in millimeters unless otherwise indicated. DIP Terminal H7EC-N@P PCB Processing Dimensions (Soldering Surface) Section occupied by the Counter DIP terminal x 8 Eight, 0.8 dia. Base 17.3 max. H7ET-NP 43 Note: Processing dimensions are for 28-pin IC socket.
H7E@-N@P Accessories (Order Separately) (Common) ■ New H7E (Except for PCB-mounting Counter) The New H7E models are supplied with a mounting bracket (Y92F-34) and nut. Additionally, the Y92F-75/-76/-77B Flush Mounting Adapters shown here allow the New H7E models to be fitted to existing panel cutouts. Y92F-35 Compact Flush Mounting Bracket Panel Cutout Single mounting 47.6 2.4 18.6 Dense mounting 4 (48 × No. of units +1.0 − 2.5) 0 26 +0.5 0 22.2 30 min. +0.5 0 RST 22.
H7E@-N@P Y92S-37 Wire-wrap Terminal (Set of Two Terminals) 44.8 Wire-wrap terminal (1 × 1 mm) 22 24 2 48 When using the Wire-wrap Terminal, be sure to use the correct wires and peripheral devices. (The correct wires, bits and sleeves are shown in the table on the right.) Y92S-36 Lithium Battery (3 V) Wire Bit 48.5 5 Sleeve 17.1 Wrapped state AWG22 2-A 2-B Normal AWG24 1-A 1-B Normal AWG26 3-A 1-B Normal 24.5 dia. 7.
H7E@-N@P Precautions (Common) Refer to Safety Precautions for All Counters. ■ New H7E (Except for PCB-mounting Counter) !WARNING !CAUTION This product has a built-in lithium battery. Do not short-circuit the + and − terminals, charge, disassemble, deform, or expose the battery to fire. The battery may explode (break), catch fire, or cause liquid leakage. Do not use any battery other than the specified one (Y92S-36).
H7E@-N@P Count Input, Timer Input or Reset Input to More than One H7E Counter at a Time AC/DC Multi-voltage Input Models • When connecting count/timer input from an SSR to the Counter that operates with AC/DC voltage input, use OMRON’s G3TA-IA/ID SSR (for DC) whose leakage current is 0.1 mA max. or connect a bleeder resistor in parallel to the input circuit of the Counter. • PNP/NPN Universal DC Voltage Input or Leakage current: 0.1 mA max.
H7E@-N@P 7. Press the Reset Key before use (not necessary for H7ER-N,-NV,NV1). (5) Tool (1) EN/IEC Standards The count or timer input, reset input, and backlight power supply terminals of the no-voltage input or PNP/NPN universal DC voltage input models (H7E@-N,-N1, H7E@-NV(-H),-NV1(-H)) are not isolated. (2) A SELV power supply conforming to Appendix H of IEC61010-1 should be used for the count or timer input, reset input and backlight power supply terminals.
H7E@-N@P Inputs PC Board (Bad Example) Do not route the wiring of the count, timer, or reset inputs in the vicinity of, or in parallel to the wiring of high-voltage or inductive load circuits (such as motors and relays). Also, keep the wiring as short as possible. PC Board (Good Example) H7E@-N@P Large-currentconsuming components Placed far away from the power supply. Large-currentconsuming components Wired in parallel with largecurrent-carrying components.
Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron).