Datasheet

H7E@-N@P
27
Accessories (Order Separately) (Common)
New H7E (Except for PCB-mounting Counter)
The New H7E models are supplied with a mounting bracket (Y92F-34) and nut. Additionally, the Y92F-75/-76/-77B Flush Mounting Adapters shown
here allow the New H7E models to be fitted to existing panel cutouts.
Degree of protection (front): IP40 (not waterproof)
The DIP switch of the H7E@-N can be operated in mounted condi-
tion. Vibration resistance and shock resistant are the same level as
the H7E@-N series.
The minimum mounting interval is 30 mm.
Note: An interval of 40 mm is recommended for easier wiring.
Do not allow the ambient temperature of the H7E@-N to exceed the
specifications (55°C).
Mounting is possible onto panels with a thickness of 1 to 5 mm.
RST
47.6
2.4 18.6 4
26
(48 × No. of units
2.5)
+1.0
0
22.2
+0.5
0
22.2
+0.5
0
45
+0.5
0
30 min.
Y92F-35 Compact Flush Mounting Bracket
Panel Cutout
Dense mounting Single mounting
28.8 24.2 22.2
45.2
48.2
53.8
4
24.8
48.8
RST
24.238 3850 22.2
27.5
48.2
52.5
60
45.2
4
31 24.2 22.2
45.2
48.2
63
72
4
26
26
45.3
63
Use mounting bracket supplied with the Counter
Panel cutout
Use mounting bracket supplied with the Counter
Panel Cutout
Y92F
-
75
Flush
Mounting
Adapter
for 26 × 45.3 Rectangular Cutout
Y92F-77B Flush Mounting Adapter
for 24.8 × 48.8 Rectangular Cutout
(Color: light gray)
Two, M4
Panel Cutout
(Color: light gray)
Use the Y92F-76 together with the Y92F-35 Compact
Flush Mounting Bracket.
Do not use the Flush Mounting Adapter supplied with the Counter.
(Color: light gray)
Two 4.5 dia. countersunk holes
Two 3.5 dia. mounting holes
Two, M3
Y92F-76 Flush Mounting Adapter
for 27.5 × 52.5 Rectangular Cutout
Note: The mounting panel
thickness should be
between 1 and 5 mm.