Datasheet

CSM_HL-5000_DS_E_3_2
1
General-purpose Limit Switch
HL-5000
Economical, Miniature Limit Switch
Boasting Rigid Construction
The Head, Box, and Cover mate with ridged surfaces to
maintain strength.
A unique Head structure provides a large OT for smooth operation.
Easy-to-wire conduit opening design.
Ideal for application in printing machines, forming machines,
and light machines.
(High Switches with high sealing characteristics, such as WL or
D4C Switches, in locations subject to oil, water, or precipitation.)
Models with grounding terminals conform to the CE marking.
Approved by CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Be sure to read Safety Precautions on page 4 to 5 and
Safety Precautions for All Limit Switches.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
å`HL-5ņņ
(1)(2)
(1) Actuators
000: Roller lever
030: Adjustable roller lever
050: Adjustable rod lever
100: Sealed plunger
200: Sealed roller plunger
300: Coil spring
(2) Ground Terminal Specifications
Blank : Without ground terminal
G : With ground terminal/M5 tapping on the rear side
Ordering Information
* HL-5000 Limit Switches are offered with a choice of ground terminal/M5
tapping on the rear side conforming to various standards. When placing an
order, add the code to the model number to indicate if ground terminal/M5
tapping on the rear side is required.
-G: with ground terminal/M5 tapping on the rear side.
Specifications
Approved Standards
Note: Ask your OMRON representative for information on approved models.
Ratings
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Approved Standard Ratings
CCC (GB14048.5)
Actuator Model
Roller lever
HL-5000 *
Adjustable
roller lever
HL-5030 *
Adjustable
rod lever
HL-5050 *
Sealed
plunger
HL-5100 *
Sealed roller
plunger
HL-5200
Coil spring
HL-5300
(Not all combinations are possible. Ask
your OMRON representative for details.)
HL-5@@
Agency Standard File No.
CCC (CQC) GB14048.5 2003010303077624
Rated
voltage
Non-inductive load (A) Inductive load (A)
Resistive
load
Lamp load
Inductive
load
Motor load
NC NO NC NO NC NO NC NO
125 VAC 51.50.7 321
250 VAC 5 1 0.5 3 1.5 0.8
12 VDC 5343
24 VDC 5343
125 VDC 0.4 0.2 −−−
250 VDC 0.4 0.2 −−−
Inrush
current
NC 24 A max.
NO 12 A max.
Applicable category and ratings
AC-15 3 A/250 VAC