Datasheet

Process Meter K3MA-J 9
Application Examples
Installation
1. Insert the K3MA-J into the panel cut-out hole.
2. For a waterproof installation, insert the rubber gasket onto the
body of the K3MA-J.
3. Fit the adaptor into the grooves on the left and right sides of the
rear case, then push it until it contacts the panel to secure the
K3MA-J.
Wiring Precautions
Use crimp terminals.
Tighten the terminal screws to a torque of approximately 0.5 N
m.
To avoid the influence of noise, route signal lines and power lines
separately.
Wiring
Use the following M3 crimp terminals.
Unit Labels (Provided)
The unit labels are not attached to the K3MA-J. Select the desired
labels from the provided sheet.
Note: For scales and gauges, use the unit labels that are specified by
the relevant laws or regulations.
Flowrate sensorDisplaying/outputting
liquid level
Monitoring interior
tank pressure
E8AA Pressure Sensor
4 to 20 mA
K3MA-J
Tank
Discharge valve
Pump
E4PA Ultra-
sonic Dis-
placement
Sensor
4 to 20 mA
or 0 to 10 V
K3MA-J
Pump
K3MA-J
4 to 20 mA
Flowrate Sensor
m/min
mm
Pa
• Monitoring gas pressure
• Inspection instruments in food or phar-
maceutical plants
• Monitoring liquid level in cleaning tanks • Monitoring sendout flowrate
• Water processing devices, etc.
• Water tanks, devices using chemicals,
etc.
5.8 mm max.
5.8 mm max.