Brochure
Average processing
You can pre-program the indicator to measure a signal/
temperature/frequency at varying sampling times (2, 4 or 8) for a
more stable read-out of the process values. This feature can also
be switched off.
Benefits to you:
• No rapid fluctuation of the display value
• No spikes on the process signal
• Read-out is better
MAX/MIN display
For daily process control of Maximum & Minimum process values
you can directly read these values out by pressing the MAX/MIN
button. Switching off the power supply resets the indicator.
Benefits to you:
• Registers batch control values
• Easy to access
• An essential feature for lots of applications
MODELEVELMAX/MIN
Current value
MAX
SHIFT UP
MAX/MIN
MIN
MODELEVELMAX/MIN SHIFT UP
MODELEVELMAX/MIN SHIFT UP
MAX value
MAX/MIN
MIN value
MAX/MIN
Features at a glance!
Colour feedback
You can choose to have the display value in Red or Green.
Both colours are available in one model. With these colours you
can give an intuitive feedback of your process (applies only to
models with outputs).
Benefits to you:
• Easy indication of process changes
• You can program the best colour for your application
• Green Okay & Red Alarm (or vice versa)
‘Out’ types
Out 1 and Out 2 can be set to operate in one of the three
following modes in accordance with the compared values
(applies only to models with output functionality).
Benefits to you:
• Three principles of basic control functionality
• Gives you control of your process
• Easy to establish your set-point
Output combinations
The output relays can be configured for advanced control
functionality, like High/High control, Low/Low control,
threshold output or a combination of these (applies only to
models with output).
Benefits to you:
• Full save operation (two outputs at one side)
• Advanced control functionality possible
• Double save operation
Upper and Lower Limits
(Outside Band Acting)
OUT1/2
upper-limit value
OUT1/2
lower-limit value
Measurement value
Hysteresis
Hysteresis
Output
ON
OFF
OUT1/2 value
Hysteresis
Output
ON
OFF
Lower Limit (Low Acting)Upper Limit (High Acting)
OUT1/2 value
Measurement value
Hysteresis
Output
ON
OFF
Upper Limit 2-stage
Output
OUT2
value
OUT2
OUT1
ON
OFF
Measurement
value
ON
OFF
OUT1
value
Threshold Output
OUT2 upper-limit
value
OUT1 upper-limit
value
OUT1 lower-limit
value
OUT2 lower-limit
value
OUT2
OUT1
ON
OFF
Measurement
value
ON
OFF
Combination of Upper Limit
and Upper/Lower Limits
OUT2 upper-limit
value
OUT1 value
OUT2 lower-limit
value
OUT2
OUT1
ON
OFF
Measurement
value
ON
OFF
Red
Red
Green
OUT2 value
OUT1 value