NS Series T h e H M I y o u c a n r e l y o n » Proven Reliability » Best Match » Machine Management Order/version: 2447841/010 (width: 210mm, height: 297mm) Print type: NS Brochure - Central Print, Full color, with extra spotcolor(s) Produced by Adnovate on 03-apr-2012 at 10:46:40 in Adobe InDesign 7.0.4.
Machine Control at your fingertips Expanding markets in emerging countries, short product cycles, and diversifying customer needs are just some of the factors that create drastic changes for the production industry. To win in severe global market competition, you have to continue to grasp industry changes quickly, understand user needs accurately, and provide diverse forms of added value.
The best match possible Machine management tool Proven reliability The amount of work and cost of connecting to Omron PLCs and components have been greatly reduced. The results is an incredible range of features that is possible only when unifying to one manufacturer.
NS Series Line-up Standard Models 15 inches 10.4 inches 12.1 inches Colour TFT NS15-TX NS12-TS 32,768 colours 32,768 colours XGA 1024 x 768 pixels SVGA 800 x 600 pixels Screen memory size: 60 MB Screen memory size: 60 MB USB Slave Controller Link USB Slave Controller Link Ethernet Video (RGB input only) Ethernet Video USB Master RGB output USB Master Ladder Monitor RS-232C x 2 Ladder Monitor RS-232C x 2 Memory Card RS-422A/485 Memory Card 8.
NSJ Series 12.1inches is unified with the Controller into one package to greatly help standardize equipment Integrated Controller Models - HMI and reduce size. 10.
THE BEST MATCH EVER The NS-series HMIs provide the highest possible compatibility with the road-proven CS/CJ-series the highest new NJ-series Controllers to achieve even greater added value in user machines. The NJ-series Machine Automation Controllers You can create a flexible, high-speed, high-precision system based on the NJ-series Machine Automation Controllers.
The CS/CJ-series PLCs for the reliability of a proven track record Features are provided to easily connect to CS/CJ-series PLCs to take advantage of their proven track record. Many features that do not require screen creation or programming support everything from design through maintenance to take advantage of the compatibility of Omron PLCs and HMI and to serve as the face of your machines.
POWERFUL SUPPORT FOR ALL USER NEEDS Design F rom conceptual designs through commissioning, operation, and maintenance, the NS Series supports every user need.
Start-up/operations ttractive, convenient A features for easier operation Features for reliability and complete maintenance 260,000-colour Video Display PAGE 26 Analog RGB Output PAGE 26 F TP Function and Web Interface User Security Functions Single Port Multi Access PAGE 28 PLC Data Trace PAGE 29 Operating log PAGE 29 Ladder Monitor PAGE 30-31 rdering and technical O information PAGE 35-39 PAGE 27 PAGE 27 Order/version: 2447841/010 (width: 210mm, height: 297m
DESIGN Troubleshooter A Troubleshooter is provided for the connected Omron controller or PLC. This greatly reduces work requirements. NJ Troubleshooter Controller errors NJ controller Standard feature for NJ-series controllers Errors are automatically detected and displayed on-screen along with corrective actions for the CPU unit function modules, EtherCAT slaves, and CJ-series units that are connected in the NJ-series controller.
CS/CJ-series PLC Troubleshooter Constantly monitors PLC errors Automatically detects PLC errors and displays the error details and recovery procedure on the screen. Even if a problem occurs, it can be resolved quickly without referring to the manuals. CS/CJ/CP-series PLC Machine Troubleshooter Easier design of machine error screens Individual error screens that were previously made for each error can now be integrated into one.
Design Best Match NS Series is the most suitable HMI for the system that comprises Omron components. The advantage is the compatibility (reducing programming and screen data creation work), which will reduce the amount of designing work.
Smart Active Parts (SAP Library) Significantly reduces the effort required to create ladder programming and screens. More than 3,000 library parts (Smart Active Parts) are available, which can directly access Omron PLCs and components. The objects can just be pasted from the Smart Active Parts (SAP Library) to the screen; it is completely unnecessary to create screens and ladder programming.
DESIGN EtherNet/IP Support for data structures This special feature is made possible by combining an Omron CJ2 PLC with an NS-series HMI. The data structures that you define on the Programming Tool can be used on the CX-Designer simply by dragging and dropping them. EtherNet/IP CJ2/NJ NS Series CX-Designer Programming Tool Drag & Drop Tag access 1 . Tag names are managed at the PLC with the CX-Programmer. A tag is a name given to an address.
Simultaneous and parallel engineering The host applications can be designed using the tag names of the PLC and HMI. Parallel development will shorten the design time. FROM ase 1 C Previously, the PLC program was first created and then the ladder program was referenced to create the screens. PLC L adder program is created. ase 2 C The screen graphics are created in advance, and then addresses are allocated and checked after the ladder program is completed. HMI screens are created.
DESIGN Direct Connection to temperature controllers Connect Omron temperature controllers directly to the NS-series HMI. Omron Temperature Controllers can be connected directly to the NS-series HMI’s RS-422A. Data does not pass through the PLC, so ladder programming is not required. Also, there are plenty of objects in the SAP Library for temperature controllers, and temperature controller screens can be created easily just by pasting objects from the SAP library to the screens.
Data logger Log large amounts of data using a personal computer. Data can be logged through background processing, with up to 160,000 points stored in one file. The logged data is stored in CSV format, and data can be displayed on data log graphs. CSV format Stored Data Example: 160,000 Points Data can be logged for approximately 7.4 days, assuming data is logged every two seconds for 12 hours a day. By using automatic file saving, data logging can be continued even longer than 7.4 days.
DESIGN Screen data security functions Protect important screen data with a password. If password protection is set in the data transfer security settings when the screen data is designed, a password must be entered to download or upload the screen data, so important screen data can be protected. Security password password between 4 and 64 A characters long can be set. The download/upload will start if the user inputs the password that was set when the screen was designed.
Multi function Execute up to 32 functions with one multifunction object. Multifunction objects combine the functions of multiple objects into one object. Multiple functions can be executed by pressing one button without using troublesome macros. Setup is easy. For example, a setting can be made on-screen using the support software to turn ON a bit to start a machine, set a value and then change the screen.
DESIGN Versatile Graphs Data Log Graph (Trend Graph) Up to 128 data can be collected in the cycle of 500ms. Logging data is stored as a CSV file in the memory card inserted in the NS-series HMI. T he log data files in the memory card appear as shown below when the read file button is pressed. Logging data is stored as a CSV file in the Memory Card mounted in the NS-series HMI. The data stored in the memory card can be read or deleted from the screen.
Good looking screens and objects “Cool” screen templates Professionally designed screen templates are provided.There are seven different types of attractive screen templates for different themes. Simply select the best template from the library. “Cool” objects Aluminium Backgrounds, buttons, labels, message boxes, and other objects are also provided for various themes.
DESIGN Screen Designer for NS Series, CX-Designer User-friendly screen creation Without screen creation and ladder programming, the CX-Designer Screen Design Software is so easy-to-use that anyone can master it. Quickly create the required screen by dragging and dropping objects. Omron’s unified development environment lets you drastically reduce the work required to create screens. All addresses and comments can be managed using a single Symbol Table.
Reading the symbol table The symbol table created in the CX-Programmer during ladder programming can be read into the CX-Designer by dragging and dropping, so it isn’t necessary to manually enter data such as input addresses and I/O comments. Tags (i.e., network symbols) can also be read into the CX-Designer.
DESIGN Reading another project’s screens and objects Resources from another project can be easily reused by just selecting the screen or objects that you want to read and dragging and dropping it, so screens can be created intuitively. Example screen 1 Example screen 2 Select the screen that you want to read, drag it to the destination and drop it. Select the part that you want to read, drag it to the destination and drop it.
Editing of multiple objects Addresses and other settings, such as labels and colours, can be set together in a list, making editing operations much more efficient. When the common attributes (such as background colour and text colour) of multiple parts are being changed, the attributes can be changed together using the property list. Example screen 1 After editing the settings in the list, press the OK Button to make the new settings effective immediately.
Startup/Operation 260,000-colour Video Display NS-CA001 Video Input Unit Four video inputs or CCD cameras can be connected and up to four images can be displayed simultaneously if the image size is 320x240 pixels. The NS-CA001 cannot be used with the NS5 or the NS15. NS-CA002 RGB/Video Input Unit There is an analog RGB input terminal in addition to the two video input terminals. Either of the video signals or the analog RGB signal can be displayed on the NS-series HMI.
FTP function. FTP (File Transfer Protocol) allows texts, lists and recipes to be replaced with the put/get command from your computer! You can even replace BMP files. WEB interface Monitor and operate the full content of any NS screen on a connected web browser. You can control the full application running on the HMI and even retrieve the log files. Operator access rights and the operating format can be set to one of five password levels.
MAINTENANCE Single Port Multi Access (SPMA) Transfer ladder program data to the PLC via the HMI. Perform online editing via the HMI. [ Computer (Serial/USB) -> NS-series HMI (Ethernet) -> PLC (Ethernet or Controller Link) -> PLC ] Keep connected. The ladder program can be transferred. CX-Programmer USB or Ethernet S N Serial connection (1:N NT Link only) Ethernet Controller Link PLC PLC Ladder program Ethernet or Controller Link Ladder program Transfer screen data via the PLC.
PLC Data Trace The PLC data trace function can be used without a computer. The PLC Data Trace function is built into the HMI in addition to the Ladder Monitor and Device Monitor. A bit’s status and operation can be viewed in a time chart just by setting the desired PLC bit’s address in the HMI. It is also now possible to display word data, save data in CSV files, and save time chart screens in BMP files.
MAINTENANCE Ladder monitor The ladder program can be monitored without a computer. Ladder programs with I/O comments can be monitored on the HMI’s screen and the ladder program can also be edited with the Programming Console function. Operation screen CS/CJ/CP-series PLC Switch Box function Also meets the requirements of users who need to display devices onsite Switch Box function The operator can check the PLC status by displaying just the I/O comments and status.
“Find Back”, “Find Next”, useful function supported by the NS-series. Reduced Time to Investigate Which Output or Input Is Causing the Problem. Device Monitor function Operation with NS-series HMI CX-Programmer Find the address at specified by the cursor. Next “N” Key Find the output from the input bit or find the input bit from the output at the cursor. Double-click “Space” Key “B” Key Return to the previous search position. .
NS-RUNTIME NS-NSRCL (NS-Runtime) Achieve machine/line monitoring and data logging on your office computer. Displaying Maintenance Information (PDF File) Monitoring Device Alarms Machine Viewer Machine viewer in an office environment. There is no need to create complex host applications. Moreover, when an alarm occurs, a PDF file can be displayed as maintenance information.
Recipe handling Checking machine data or switching processes from a host computer is easy. Parameter groups in the PLC can be transferred together to a computer, and the transferred data can be checked and edited in CSV format, e.g., using Excel. The edited data can then be transferred together back to the PLC. CSV format Recipe data Easy installation To get started, just install the NS-Runtime in the computer and place the screen data in the applicable folder.
HAND-HELD HMI NSH5 Series A hand-held version of the NS5 is now available to perform operations at the production site. The NS-series HMI’s have a complete set of functions that can be used at the production site, such as the SAP Library, multi-language support, and Programming Console functions. Memory Card Interface and USB Slave Connector. Function Switches Use the ten functions switches. F1, F2, F6, F7: Wired outputs F3 to F5, F8 to F10: Communications outputs Emergency Stop Switch.
NS Series Ordering Information International Standards The standards are availabled as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives. Contact your OMRON representative for further details and applicable conditions for these standards.
NS Series Software ●How to select required support software for your controller The required support software depends on the controller to connect. Please check the following table when purchasing the support software.
NS Series Cable Product name Cable *1 NSH5 Cables UL-compliant NSH5 Cable PT-to-PLC Connecting Cable *2 NSH5 Removable Box Cable Specifications Model Screen transfer cable for DOS/V (CX-Designer PT) Length: 2 m XW2Z-S002 USB-Serial Conversion cable Length: 0.
NS Series Options Product name Video Input Unit Specifications Model Inputs: 4 channels Signal type: NTSC/PAL Standards NS-CA001 UC1, CE Special Cable for the Console Input channels: 2 video channels and 1 RGB channel *1 Signal type: NTSC/PAL NS-CA002 Cable length: 2 m F150-VKP (2 m) Cable length: 5 m F150-VKP (5 m) For Controller Link Communications NS-CLK21 Transmission distance: 500 m total length Note: Use this model when connecting PT models without a V@ suffix.
NS Series General Specifications NS5/NS8/NS10/NS12/NS15 Series Rated power supply voltage NS5-V2 NS8-V2 NS10-V2 NS12-V2 NS15-V2 24 VDC Allowable voltage range 20.4 to 27.6 VDC (24 VDC 15%) Power consumption 15 W max. Ambient operating temperature 0 to 50 C (See note on the next page.) Note: The ambient operating temperature is subject to the following restrictions according to the mounting angle.
Omron Europe B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu Austria Tel: +43 (0) 2236 377 800 www.industrial.omron.at Germany Tel: +49 (0) 2173 680 00 www.industrial.omron.de Portugal Tel: +351 21 942 94 00 www.industrial.omron.pt Turkey Tel: +90 212 467 30 00 www.industrial.omron.com.tr Belgium Tel: +32 (0) 2 466 24 80 www.industrial.omron.be Hungary Tel: +36 1 399 30 50 www.industrial.omron.